Black Box SW591C, SW590A-R2 manual Quick Reference Guide, Individual Port Switch Bank Settings

Page 21

Quick Reference Guide

Quick Reference Guide

Individual Port Switch Bank Settings

 

 

 

 

 

Switch Position Setting

 

 

 

Option

1

2

3

4

5

6

7

 

 

 

 

 

 

 

 

 

 

 

 

Speed

 

 

 

 

 

 

 

 

 

 

110 bps

ON

ON

 

ON

 

 

 

 

 

300 bps

OFF

ON

 

ON

 

 

 

 

 

600 bps

ON

OFF

 

ON

 

 

 

 

 

1200 bps

OFF

OFF

 

ON

 

 

 

 

 

2400 bps

ON

ON

 

OFF

 

 

 

 

 

4800 bps

OFF

ON

 

OFF

 

 

 

 

 

9600 bps

ON

OFF

 

OFF

 

 

 

 

 

19200 bps

OFF

OFF

 

OFF

 

 

 

 

 

Parity

 

 

 

 

 

 

 

 

 

 

none

 

 

 

 

 

OFF

OFF

 

 

 

even

 

 

 

 

 

OFF

ON

 

 

 

odd

 

 

 

 

 

ON

OFF

 

 

 

Word Size

 

 

 

 

 

 

 

 

 

 

7 bits per word

 

 

 

 

 

 

 

OFF

 

 

8 bits per word

 

 

 

 

 

 

 

ON

 

 

Flow Control

 

 

 

 

 

 

 

 

 

 

Hardware (DTR/CTS)

 

 

 

 

 

 

 

 

ON

 

Software (X-ON/X-OFF)

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Settings for Switch Option F

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Position Setting

 

 

 

Option

1

2

3

4

5

6

7

8

Link from master

ON

ON

 

 

 

 

 

 

 

“ ” from slave

OFF

ON

 

 

 

 

 

 

 

“ ” from either

ON or OFF

OFF

 

 

 

 

 

 

 

Time Out

 

 

 

 

 

 

 

 

 

 

2.5 minutes

 

 

 

 

 

 

ON

ON

 

 

5 minutes

 

 

 

 

 

 

OFF

ON

 

 

10 minutes

 

 

 

 

 

 

ON

OFF

 

 

Disabled

 

 

 

 

 

 

OFF

OFF

 

 

Graphics Pause

 

 

 

 

 

 

 

 

 

 

50 milliseconds

 

 

 

 

 

 

 

 

ON

ON

100 milliseconds

 

 

 

 

 

 

 

 

OFF

ON

500 milliseconds

 

 

 

 

 

 

 

 

ON

OFF

1.5 second

 

 

 

 

 

 

 

 

OFF

OFF

21

Image 21
Contents Code Operated Switch II 4-Port Expansion Board Code Operated Switch Contents Memory 8K buffer Enclosure Steel SpecificationsIntroduction Installation Setting the DIP switchesIntroduction Installation Functions and Arrangement of the Switch BanksBank Assignments Configuring Ports with the Individual Port Switch BanksTo Set This Mode Timeout SettingSet SWF To Set a PauseLSB MSB Ascii LSB MSB Ascii Ctrl HEX LSB 128 174 For Self-Test FunctionSending or Suppressing Breaks Signal direction Configuring Ports for DTE or DCEMaster Slave Leads passed DTE Port DCE PortConnecting and Powering Up the COS-II Text Mode Signaling a LockGraphics Mode OperationIndicators Front-Panel ButtonSelf-Tests Serial Port Test Interrupt TestAll Tests Individual Port Switch Bank Settings Settings for Switch Option FQuick Reference Guide System Switch Options Available through Position Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax