Black Box SW590A-R2, SW591C manual LSB MSB Ascii

Page 10

CODE OPERATED SWITCH II

3.6.2SETTING THE ARMING CHARACTER WITH SWG

Switch Bank SWG supplies a portion of the control-code sequence, the sequence that activates the Switch. The arming character, the ASCII code that alerts the COS-II to an upcoming switch action, is set with SWG. The settings are given in the chart below. For a more detailed explanation of control codes, see Section 4.2. A note on abbreviations: LSB stands for least significant bit, MSB for most significant bit.

ARMING CHARACTER SWITCH POSITIONS

 

 

 

 

 

 

 

 

 

 

 

 

LSB

 

 

 

 

 

 

MSB

ASCII

CTRL

HEX

DECIMAL

1

2

3

4

5

6

7

8

NUL

@

00

0

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

SOH

A

01

1

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

STX

B

02

2

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

ETX

C

03

3

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

EOT

D

04

4

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

ENQ

E

05

5

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

ACK

F

06

6

OFF

ON

ON

OFF

OFF

OFF

OFF

OFF

BEL

G

07

7

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

BS

H

08

8

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

HT

I

09

9

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

LF

J

0A

10

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

VT

K

0B

11

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

FF

L

0C

12

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

CR

M

0D

13

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

SO

N

0E

14

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

SI

O

0F

15

ON

ON

ON

ON

OFF

OFF

OFF

OFF

DLE

P

10

16

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

DC1

Q

11

17

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

DC2

R

12

18

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

DC3

S

13

19

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

DC4

T

14

20

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

NAK

U

15

21

ON

OFF

ON

OFF

ON

OFF

OFF

OFF

SYN

V

16

22

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

ETB

W

17

23

ON

ON

ON

OFF

ON

OFF

OFF

OFF

CAN

X

18

24

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

EM

Y

19

25

ON

OFF

OFF

ON

ON

OFF

OFF

OFF

SUB

Z

1A

26

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

ESC

[

1B

27

ON

ON

OFF

ON

ON

OFF

OFF

OFF

FS

\

1C

28

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

GS

]

1D

29

ON

OFF

ON

ON

ON

OFF

OFF

OFF

RS

^

1E

30

OFF

ON

ON

ON

ON

OFF

OFF

OFF

US

_

1F

31

ON

ON

ON

ON

ON

OFF

OFF

OFF

SP

 

20

32

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

!

 

21

33

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

"

 

22

34

OFF

ON

OFF

OFF

OFF

ON

OFF

OFF

#

 

23

35

ON

ON

OFF

OFF

OFF

ON

OFF

OFF

$

 

24

36

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

%

 

25

37

ON

OFF

ON

OFF

OFF

ON

OFF

OFF

&

 

26

38

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

10

Image 10
Contents Code Operated Switch II 4-Port Expansion Board Code Operated Switch Contents Specifications Memory 8K buffer Enclosure SteelIntroduction Setting the DIP switches InstallationIntroduction Functions and Arrangement of the Switch Banks InstallationConfiguring Ports with the Individual Port Switch Banks Bank AssignmentsSet SWF Timeout SettingTo Set This Mode To Set a PauseLSB MSB Ascii LSB MSB Ascii Ctrl HEX LSB 128 174 Self-Test Function ForSending or Suppressing Breaks Master Slave Leads passed Configuring Ports for DTE or DCESignal direction DTE Port DCE PortConnecting and Powering Up the COS-II Graphics Mode Signaling a LockText Mode OperationFront-Panel Button IndicatorsSelf-Tests Interrupt Test Serial Port TestAll Tests Settings for Switch Option F Individual Port Switch Bank SettingsQuick Reference Guide System Switch Options Available through Position Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax