Hardware Installation (continued)
•After setting the DIP switches on the slave unit, connect the computers using the same procedure outlined in steps 5 to 9 in the previous section. DO NOT POWER UP THE COMPUTERS YET.
•Using the
“Master Input/ Slave Output” of the unit. Refer to the diagram above.
• If the previous unit is the MASTER, then the other end of the cable connects to the “MasterEn Input/Slave Output” port of the MASTER (such as cable 1 in the previous diagram).
•If the previous unit is a slave, then the other end goes to the “Slave Input” port of the previous slave unit (such as cables 2 and 3 in the diagram above).
•Upon connecting the
•RESET the MASTER unit by pressing the BANK/SCAN and CHANNEL buttons simultaneously. This is necessary for the MASTER unit to detect the newly added slave unit.
•Verify that the MASTER unit has detected the new slave by pressing the BANK/SCAN button. If it detected the new slave properly, the LED display on the MASTER will register the slave units bank address. If you have many slave units, you may have to press the BANK/SCAN button many times to cycle through all of the preexisting slave units before reaching the newly added unit.
•Now you can power up the computers connected to the newly added slave unit. After all the computers have booted up, you may need to RESET the MASTER unit again to detect the presence of powered computers on the new slave unit.
NOTE: The OmniView™ PRO can also be