WARNING: Explosion hazard

Do not use this product where there are flammable fumes or gases, such as in the bilge of a gasoline- powered boat, or near propane tanks. Do not use this product in an enclosure containing automotive-type lead acid batteries. These batteries, unlike the sealed AGM battery in XPower Powerpack, vent explosive hydrogen gas which can be ignited by sparks from electrical connections.

When working on electrical equipment, always ensure someone is nearby to help you in an emergency.

WARNING: Heated surface

Ensure at least 2" (5 cm) air space is maintained on all sides of the XPower Powerpack. During operation, keep away from materials that may be affected by high temperatures such as blankets, pillows and sleeping bags.

WARNING: Fire hazard

Never allow jump-start cables’ red and black clamps to touch each other or another common metal conductor. This could cause damage to the unit and/or create a sparking/explosion hazard. Always disconnect the jump-start cables from the unit after use and clip the plastic guard over the jump-start cable port.

WARNING: Fire hazard

Jump-start cable clamps must be connected positive to positive (red clamp to battery “+”) and negative to negative (black clamp to battery -”). A reverse polarity connection (positive to negative) may cause damage to the unit and/or create a sparking/explosion hazard.

WARNING: Fire hazard

The jump-start feature is designed for short term operation only— less than 4 seconds. Operating the jump-start feature for more than 4 seconds may cause damage to the unit. Allow the XPower Powerpack to cool down for at least 3 minutes after each jump- start.

975-0162-01-01

v

Image 7
Contents Owner’s Guide Powerpack 400 RDate and Revision Conventions Used Purpose Related Information References to XPower PowerpackImportant Safety Instructions Figure i Basic Safety Important Safety Instructions Precautions When Working With Batteries 975-0162-01-01 Vii Precautions for Using Rechargeable Appliances Contents Operation Troubleshooting MaintenanceSpecifications Xii Figures Xiv Automatic Overload About the XPower PowerpackIntroduction Comprehensive ProtectionJump-Start Cables Safety Fuse Low Battery ProtectionOverheating Contents FeaturesFront Panel XPower Powerpack FeaturesDC Power Socket can Feature DescriptionCompressor Nozzle Adaptor compartment Storage CompartmentBack Panel Radio Enlargement Radio XPower Powerpack 400 R onlyAir Compressor 5Air Compressor FeaturesEmergency Light and Jump-Start Port Light ON/OFF Switch 400 Plus Light ON/OFF/Pulse Switch 400R7Accessories and Accessory Bag AccessoriesOperating Conditions and Guidelines OperationChoosing a Location Dry Cool Ventilated Safe Protected from battery gasesRecharging the XPower Powerpack Battery Charging with the AC Charger 2Charging with AC Power Charging with the DC-to-DC Accessory Cable 3Charging with DC Power Recharging with a Generator’s Regulated 12 Vdc Outlet To recharge with a solar panel Recharging From a Solar Panel5Checking the State-of-Charge Checking the State-of-ChargeAC Appliance Watts a Hours b AC AppliancesOperating AC Appliances Low-Battery AlarmOverload Protection Vdc Appliance Watts a Hours b Vdc Appliances7Operating AC Appliances Operating DC AppliancesControl Panel Operation Required How to Condition ActionCharging Status Jump-Starting a Vehicle’s Engine To jump-start a vehicle or boat engine 10Emergency Light Using the Emergency Light11Using the Emergency Light Using the Air Compressor 12XPower Powerpack Air Compressor To use a Nozzle Adapter Over-Temperature Safety ProtectionOther Inflatables Inflating TiresTires Bicycle TiresTo inflate your vehicle, motorcycle, or bicycle tires To inflate small sports equipment Inflating Small Sports EquipmentRadio Features Power DrawListening to the AM Band Radio Operation Required How to Condition Required ActionConnecting to an External Battery 18Basic Jump-start Cable Safety 19Connecting the XPower Powerpack to an External Battery Battery Maintenance MaintenanceBattery Life Replacing the Internal BatteryBattery Capacity Ah Obtaining a Replacement BatteryFasteners Battery Replacement ProcedureTo replace a light bulb Replacing the Incandescent LightTo replace the external fuse Replacing the External FuseRecycling Maintenance 975-0162-01-01 Electrical Specifications SpecificationsDC Section Internal Battery Charging Controller System AC Power SectionAccessories Radio XPower Powerpack 400 R onlyAir Compressor XPower Powerpack Physical specifications Plus 400 R Physical SpecificationsTelevision Interference TroubleshootingCommon Problems Buzz in Audio EquipmentProblem Possible Cause Solution Troubleshooting Reference1Troubleshooting reference Charging Green Voltage at the AC Use AC wall outlet that supplies 1Troubleshooting reference Warranty Warranty and ReturnProduct DisclaimerExclusions Return Material Authorization PolicyOut of Warranty Service Return ProcedureSerial Number Purchased From Purchase Date Information About Your SystemWA-6