Troubleshooting
Table 5-1 Troubleshooting reference
Problem | Possible Cause | Solution |
|
|
|
Run time is | Internal battery is not | Recharge using the AC Charger, |
less than | fully charged. | until green Charging Status light is |
expected. |
| steady. |
| AC appliance power | Check AC appliance power or |
| consumption is higher | wattage rating (or current draw for |
| than expected. | 12 V dc appliances) and compare |
|
| with Table |
|
| Table |
|
| For additional information on |
|
| battery run times, see the Battery |
|
| App Note under the Support Section |
|
| at www.xantrex.com. |
|
|
|
Charging | No AC power at the | Ensure power is available at the AC |
Status light is | AC wall outlet. | wall outlet. |
OFF when AC | AC Charger is faulty. | Replace the AC Charger. |
Charger is | ||
connected |
|
|
|
|
|
Green | Battery Charge (%) | Unplug the charging sources and any |
Charging | reading on digital | appliances and let the XPower |
Status light is | display is only | Powerpack rest for 15 minutes to |
flashing | accurate when the | obtain an accurate reading. |
(indicating | XPower Powerpack |
|
recharging) | has been disconnected |
|
and Battery | from all appliances |
|
Charge (%) | and all charging |
|
does not turn | sources for fifteen |
|
on. | minutes. |
|
|
|
|
The | The compressor may | Turn off the compressor and let it |
compressor | have overheated from | cool down. |
runs slowly. | excessive use. |
|
| Battery voltage is too | Check the condition of the internal |
| low. | battery. The battery may need to be |
|
| recharged or replaced. |
|
|
|