Xantrex Technology XDC 150-40SL, XDC 6000 manual Current Share Configuration Setup Sharing Network

Page 23

TM-XDSL-01XN.book Page 21 Tuesday, November 5, 2002 3:22 PM

Current Sharing

Overview

Current Share Configuration

Setup

Current

Sharing

Network

Units are programmed in a mode such that it is already in current sharing mode on power up. This feature is not user-modifiable. Please contact the manufacturer for assistance if you wish to change this.

Most configurable settings available on a master 6kW unit are disabled on the slave units for protection. All the queries are still available.

To set up multiple supplies for current share operation, follow these steps:

1.Power down the units. Connect the CAN ports of all paralleled units as explained in “CANbus Setup”.

2.Make load connections. It is recommended to keep load cables the same length if possible. See Figure 3.1.

3.Power up the master.

4.Power up the slaves one at a time.

5.Set the voltage and current on the master, then enable the output.

Release 1.0

21

Image 23
Contents XDC 6000 Watt Series Slave Power Supply TM-XDSL-01XN.book Page ii Tuesday, November 5, 2002 322 PM XDC 6000 Watt Series Limited Warranty What does this warranty not cover? Disclaimer Product Release Release 1.0 Information About Your Power SupplyPower Supply Safety Unit complies with Canadian EMC requirements of ICES-001 Approvals CE MarkViii Revisions Who Should Use This ManualAbout This Manual Table of Contents Table of Contents Xii Overview FeaturesSlave Front Panel Front PanelAC Input Power AC Input Wire AC Input ConnectorAC Wire Input Connection Attaching the AC Input Wires Overview Current SharingSetup Current Share Configuration Setup Sharing Network Operation SpecificationsAppendix A. Specifications and Characteristics Electrical Specifications-Summary Table A.3Specifications for 80V to 600V Models AC Line Input Voltage Operating Ranges AC Line Input SpecificationsProgramming Range for Voltage, Current, and Power Output Performance SpecificationsTypical Measurement Resolution Typical 31 kHz 62 kHz output ripple Minimum 4 ms at full load International Approvals Environmental SpecificationFigure A.1 Power Supply Dimensions Mechanical SpecificationTM-XDSL-01XN.book Page 33 Tuesday, November 5, 2002 322 PM Xantrex Technology Inc