Specifications and Characteristics
Electrical
Table A.3Specifications for 80V to 600V Models
Models | |||||
|
|
|
|
|
|
Output Ratings: |
|
|
|
|
|
Output Voltage 1 | |||||
Output Current 2 | |||||
Output Power | 6000 W | 6000 W | 6000 W | 6000 W | 6000 W |
|
|
|
|
|
|
Line Regulation: 3 |
|
|
|
|
|
Voltage (0.01% of Vmax) | 8 mV | 10 mV | 15 mV | 30 mV | 60 mV |
Current (0.05% of Imax) | 37.5 mA | 30 mA | 20 mA | 10 mA | 5 mA |
|
|
|
|
|
|
Load Regulation: 4 |
|
|
|
|
|
Voltage (0.05% of Vmax + 5 mV) | 45 mV | 55 mV | 80 mV | 155 mV | 305 mV |
Current (0.1% of Imax + 20 mA) | 95 mA | 80 mA | 60 mA | 40 mA | 30 mA |
|
|
|
|
|
|
Output Noise |
|
|
|
|
|
Voltage | 100 mV | 100 mV | 150 mV | 250 mV | 350 mV |
|
|
|
|
|
|
Output Ripple (rms): |
|
|
|
|
|
Voltage | 15 mV | 20 mV | 20 mV | 30 mV | 80 mV |
Current 5 | 320 mA | 230 mA | 120 mA | 50 mA | 25 mA |
OVP Adjustment Range: |
|
|
|
|
|
(0% to 110% of Vmax) | |||||
|
|
|
|
|
|
Efficiency: 6 | 0.89 | 0.90 | 0.90 | 0.91 | 0.91 |
1.Minimum output voltage is <0.3% of rated voltage at zero output setting.
2.Minimum output current is <0.2% of rated current at zero output setting when measured with rated load resistance.
3.For input voltage variation over the AC input voltage range, with constant rated load.
4.For
5.Current mode noise is measured from 10% to 100% of rated output voltage, full current, unit in CC mode.
6.Typical efficiency at nominal input voltage and full output power.
Table A.4Drift Specifications for 80V to 600V Models
Models | |||||
|
|
|
|
|
|
Drift (30 minutes): 1 |
|
|
|
|
|
Voltage (0.04% of Vmax) | 32 mV | 40 mV | 60 mV | 120 mV | 240 mV |
Current (0.6% of Imax) | 450 mA | 360 mA | 240 mA | 120 mA | 60 mA |
|
|
|
|
|
|
Drift (8 hours): 2 |
|
|
|
|
|
Voltage (0.02% of Vmax) | 16 mV | 20 mV | 30 mV | 60 mV | 120 mV |
Current (0.04% of Imax) | 30 mA | 24 mA | 16 mA | 8 mA | 4 mA |
|
|
|
|
|
|
Temperature Coefficient: 3 |
|
|
|
|
|
Voltage (0.04% of Vmax/°C) | 32 mV | 40 mV | 60 mV | 120 mV | 240 mV |
Current (0.06% of Imax/°C) | 45 mA | 36 mA | 24 mA | 12 mA | 6 mA |
|
|
|
|
|
|
1.Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
2.Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute
3.Change in output per °C change in ambient temperature, with constant line and load.
Release 1.0 | 25 |