Current Sharing

Operation

Operation

There can only be one master unit and 4 slave units current sharing. All other units will not current share. Units must have the same output ratings or they will not current share.

Once a current sharing network is setup, you may adjust the voltage setpoint on the master. The master will automatically adjust the setpoints of the slave units to equalize the current output of all units. You may also disable or enable the output of the master, automatically disabling or enabling the output of all slaves.

When a slave’s output is disabled for any reason, the master will disable the entire current sharing network.

You may use local or remote (RS-232, GPIB, multichannel or analog) control to operate the master.

Slaves will be operating under remote control from the master and in local lockout. Hence, they will only respond to remote queries.

The current limit setpoint on the master is still the current limit for a single unit, not the current limit for the entire current sharing network. Please see the operating manual shipped with your master unit (full digital controlled front panel unit).

Power supplies may not enter calibration mode while current sharing, or enter current share operation while in calibration mode. To enter calibration mode, turn off all other units on the CANbus network.

Errors A master or slave will be disabled from current sharing (set to "No share") if:

there is more than one master connected to the CANbus, (Error +1811)

there are more than 4 slaves, (Error +1822), or

the model does not match that of the master’s, (Error +1822).

Specifications

Max units on bus

49

 

 

Max current share units

5

 

 

Max cable length

40m

 

 

Bus speed

700 kbits/sec.

 

 

Termination

120 ohm, 1/4 Watt

 

 

Connections

parallel male DB9 to female DB9 cable

 

 

22

Operating Manual for XDC Series Slave Power Supply

Image 24
Contents XDC 6000 Watt Series Slave Power Supply TM-XDSL-01XN.book Page ii Tuesday, November 5, 2002 322 PM XDC 6000 Watt Series Limited Warranty What does this warranty not cover? Disclaimer Product Information About Your Power Supply Release Release 1.0Power Supply Safety Approvals CE Mark Unit complies with Canadian EMC requirements of ICES-001Viii Who Should Use This Manual RevisionsAbout This Manual Table of Contents Table of Contents Xii Features OverviewFront Panel Slave Front PanelAC Input Power AC Input Connector AC Input WireAC Wire Input Connection Attaching the AC Input Wires Current Sharing OverviewSetup Current Share Configuration Setup Sharing Network Specifications OperationAppendix A. Specifications and Characteristics Electrical Specifications-Summary Table A.3Specifications for 80V to 600V Models AC Line Input Specifications AC Line Input Voltage Operating RangesOutput Performance Specifications Programming Range for Voltage, Current, and PowerTypical Measurement Resolution Typical 31 kHz 62 kHz output ripple Minimum 4 ms at full load Environmental Specification International ApprovalsMechanical Specification Figure A.1 Power Supply DimensionsTM-XDSL-01XN.book Page 33 Tuesday, November 5, 2002 322 PM Xantrex Technology Inc