Specifications and Characteristics
Output Performance Specifications
Typical Programming Resolution
Remote Digital Interface
Voltage | 0.002% of Vmax |
Current | 0.002% of Imax |
Power | 0.05% of Pmax |
Over Voltage Protection | 0.002% of Vmax |
|
|
Typical Measurement Resolution
Remote Digital Interface
Voltage | 0.002% of Vmax |
Current | 0.002% of Imax |
Power | 0.05% of Pmax |
|
|
Programming Accuracy1
Remote Digital Interface
Voltage Programming | 0.1% of Vmax |
Current Programming | 0.5% of Imax |
Power Programming | 0.5% of Pmax |
Over voltage | 0.1% of Vmax |
Programming |
|
|
|
Readback Accuracy
Remote Digital Interface
Voltage Readback | 0.15% of Vmax |
Current Readback | 0.5% of Imax |
Power Readback | 0.5% of Pmax |
|
|
30 Minute Drift2
Voltage | 0.04% of Vmax |
|
|
Current | 0.6% of Imax |
|
|
Power | 1% of Pmax |
|
|
1.Accuracy specifications apply for settings in range of 1% to 100% of rated output
2.At 25°C ±5°C, with full power load
28 | Operating Manual for XDC Series Slave Power Supply |