Xantrex Technology XDC 40-150SL, XDC 6000, XDC 80-75SL, XDC 600-10SL AC Line Input Specifications

Page 28

TM-XDSL-01XN.book Page 26 Tuesday, November 5, 2002 3:22 PM

Specifications and Characteristics

AC Line Input Specifications

AC Line Input Specifications

The input to the power supply requires the following specifications.

AC Line Input

Voltage

Operating

Ranges

Table A.5AC Line Input Specifications

Operating Range

 

nominal 208Vrms (Standard)

190 to 242 Vac 3 φ (3 wire + safety ground)

nominal 400Vrms (with HV-Input option)

342 to 500 Vac 3 φ (3 wire + safety ground)

Frequency Range

47 to 63 Hz

 

 

Maximum Peak In-rush Current at turn on

35 Arms

 

 

Minimum Power Factor1

 

nominal 208Vrms (Standard)

0.95

nominal 400Vrms (with HV-Input option)

0.9

Operating Current

 

nominal 208Vrms (Standard)

 

Maximum2

24 A

Typical3

20 A

Operating Current

 

nominal 400Vrms (with HV-Input option)

 

Maximum4

13 A

Typical5

11 A

1.At nominal input voltage and maximum power

2.At 190Vac input voltage, 55°C ambient temperature and maximum power

3.At 208Vac input voltage, 25°C ambient temperature and maximum power

4.At 342Vac input voltage, 50°C ambient temperature and maximum power

5.At 400Vac input voltage, 25°C ambient temperature and maximum power

26

Operating Manual for XDC Series Slave Power Supply

Image 28
Contents XDC 6000 Watt Series Slave Power Supply TM-XDSL-01XN.book Page ii Tuesday, November 5, 2002 322 PM XDC 6000 Watt Series Limited Warranty What does this warranty not cover? Disclaimer Product Information About Your Power Supply Release Release 1.0Power Supply Safety Approvals CE Mark Unit complies with Canadian EMC requirements of ICES-001Viii Who Should Use This Manual RevisionsAbout This Manual Table of Contents Table of Contents Xii Features OverviewFront Panel Slave Front PanelAC Input Power AC Input Connector AC Input WireAC Wire Input Connection Attaching the AC Input Wires Current Sharing OverviewSetup Current Share Configuration Setup Sharing Network Specifications OperationAppendix A. Specifications and Characteristics Electrical Specifications-Summary Table A.3Specifications for 80V to 600V Models AC Line Input Specifications AC Line Input Voltage Operating RangesOutput Performance Specifications Programming Range for Voltage, Current, and PowerTypical Measurement Resolution Typical 31 kHz 62 kHz output ripple Minimum 4 ms at full load Environmental Specification International ApprovalsMechanical Specification Figure A.1 Power Supply DimensionsTM-XDSL-01XN.book Page 33 Tuesday, November 5, 2002 322 PM Xantrex Technology Inc