Xantrex Technology RS232-XPD manual User Options and Settings, OVP Control Mode Selection

Page 30

Installation and Configuration

User Options and Settings

User Options and Settings

CAUTION

If you remove the unit's cover, use proper static control techniques to avoid damage to static-sensitive components on the printed circuit board.

You can customize remote operation settings for OVP (over voltage protection) control and TTL shutdown by changing jumper positions on the RS-232 PCB. Refer to the operating manual for information on how to use over voltage protection and TTL shutdown.

OVP Over voltage protection (OVP) on the RS-232 interface is set at the factory for Selection remote software operation. When operating the power supply in remote mode, you

control the OVP trip level using the OVSET software command. If you return the power supply to local operation by using the REM software command, control of the OVP trip level changes from software control to the front panel OVP potentiometer. The default OVP trip level is set as 110% of the power supply's rated output voltage. See Table 2.10, on page 24 for a complete list of remote power ON default settings.

You can isolate the location of OVP control by changing the positions of the Local OVP Control jumper J2 and the Remote OVP Control jumper J20, both on the RS-232 interface PCB. The default jumper settings allow control of OVP to depend on the operating state of the power supply. By physically changing the jumper settings, you can isolate the location of OVP control to software control only or front panel control only. Table 2.12, “OVP Control Mode Selection” shows a table of jumper settings and OVP programming selection. Refer to “Basic Setup Procedure” on page 19 for the positions of the jumpers on the RS-232 PCB.

Table 2.12 OVP Control Mode Selection

PCB Jumper J2

PCB Jumper

OVP Programming Selection

Position

J20 Position

 

Closed (default)

Closed (default)

Software or Front Panel OVP control

 

 

(dependent on the power supply operating state)

Closed

Open

Software OVP control only

Open

Closed

Front Panel OVP control only

Open

Open

Front Panel OVP control only

28

Operating Manual for RS-232 for XPD Series Power Supply

Image 30
Contents RS232-XPD Page Internal RS-232 Interface for XPD 500 Watt Series How do you get service? Phone 604 422 Toll Free North America 800 667 Fax 604 421What does this warranty not cover? Disclaimer Product Information About Your Power Supply Model Number Serial Number Purchased From Purchase DateSafety SupplyMain Sections Manual RevisionsAbout This Manual Contents Contents Features and Specifications DescriptionFeatures and Specifications Features and FunctionsFeatures Readback FunctionsSpecifications Models 18-30 33-16 60-9 120-4.5Features and Specifications Introduction Initial InspectionInstallation and Configuration Initial InspectionRS-232 Interface Subplate Located on Power Supply Rear Panel RS-232 Interface PCB Basic Setup Procedure Step # Description Action ReferenceFlow Switch Setting Condition CommunicationsBaud Rate XON Switch Setting Condition Jumper Connections RS-232 Connector PinPower Supply DCE Host Computer DTE Pin connector Jumper J10 Connections RS-232 Connector PinSwitch Position Power on results RemoteStartup Condition Default Settings Model Example IsetExample RS-232 Connector J4 Pinouts default configuration RS-232 ConnectionPower Supply Settings Parameter SettingUser Options and Settings 12 OVP Control Mode SelectionHigh OFF LOW User Signals User Signals J21 ConnectorJ21 User Signal Connector Circuit Block Diagram J21 User Cable with Ferrite Block Command Syntax RS-232 OperationOperation FormatParameter Description Form Floating Number Definition ExampleOperation Command Summary Command DescriptionAUXA? Cmode Command Reference Auxa 1 onResponse DLY seconds Lockout. See also Remote/Local Operation on Snsp Remote/Local Operation on Status, and Fault Registers on Section Accumulated Status, Status, and Fault Registers Condition Mnemonic Bit Position Bit Weight 4096Error Codes Error # Error Identification ExplanationTroubleshooting LEDsCalibration Voltage Program Calibration Procedure Voltage Mode CalibrationSetup VoltageVoltage Readback Calibration Procedure Current Mode Calibration Current Calibration SetupCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc