Xantrex Technology RS232-XPD manual Command Reference, Auxa 1 on

Page 42

Operation

Command Reference

Command Reference

Table 3.7 Command Reference

Command

Description

ASTS?

Asks for the supply’s accumulated status register. The accumulated status

 

register stores any bit that was entered in the status register since the

 

accumulated status query command (ASTS?) was last used, regardless of

 

whether the condition still exists. The accumulated status register has the

 

same bits, weights, and conditions as the status register. A bit in the

 

accumulated status register will be set at 1 if the corresponding bit in the

 

status register has been 1 (TRUE) at any time since the register was last

 

read. See “Accumulated Status, Status, and Fault Registers” on page 47.

 

The ASTS? query clears the status register.

 

Response: ASTS <status mask> where status mask is the decimal

 

equivalent of the total bit weights for the operating conditions as listed in the

 

status register.

AUXA <1/ON>,<0/OFF>

Controls the AUXA output signal level at rear panel connector J21-7. Active

 

low.

 

Initial value: AUXA 0

AUXA?

Asks for the present set value of the AUXA output signal.

 

Response: AUXA 0 (OFF)

 

AUXA 1 (ON)

AUXB <1/ON>,<0/OFF>

Controls the AUXB output signal level at rear panel connector J21-8. Active

 

low.

 

Initial value: AUXB 0

AUXB?

Asks for the present set value of the AUXB output signal.

 

Response: AUXB 0 (OFF)

 

AUXB 1 (ON)

CLR

Initializes the power supply to its power ON condition. If issued while in local

 

mode, CLR will force power supply settings to register default values as in

 

but these default settings will not come into effect until the power supply is

 

switched to remote mode operation. The CLR commands will clear faults

 

from the fault register. CLR will not reset CMODE.

 

 

CMODE <1/ON>,<0/OFF>

CMODE ON places the power supply into calibration mode for processing

 

calibration commands.

 

Initial value: CMODE OFF or CMODE 0

 

 

CMODE?

Asks for the power supply’s calibration mode status.

 

Response: CMODE 0 (disabled)

 

CMODE 1 (enabled)

 

 

40

Operating Manual for RS-232 for XPD Series Power Supply

Image 42
Contents RS232-XPD Page Internal RS-232 Interface for XPD 500 Watt Series How do you get service? Phone 604 422 Toll Free North America 800 667 Fax 604 421What does this warranty not cover? Disclaimer Product Information About Your Power Supply Model Number Serial Number Purchased From Purchase DateSafety SupplyMain Sections Manual RevisionsAbout This Manual Contents Contents Features and Specifications DescriptionFeatures and Specifications Features and FunctionsFeatures Readback FunctionsSpecifications Models 18-30 33-16 60-9 120-4.5Features and Specifications Introduction Initial InspectionInstallation and Configuration Initial InspectionRS-232 Interface Subplate Located on Power Supply Rear Panel RS-232 Interface PCB Basic Setup Procedure Step # Description Action ReferenceFlow Switch Setting Condition CommunicationsBaud Rate XON Switch Setting Condition Jumper Connections RS-232 Connector PinPower Supply DCE Host Computer DTE Pin connector Jumper J10 Connections RS-232 Connector PinSwitch Position Power on results RemoteStartup Condition Default Settings Model Example IsetExample RS-232 Connector J4 Pinouts default configuration RS-232 ConnectionPower Supply Settings Parameter SettingUser Options and Settings 12 OVP Control Mode SelectionHigh OFF LOW User Signals User Signals J21 ConnectorJ21 User Signal Connector Circuit Block Diagram J21 User Cable with Ferrite Block Command Syntax RS-232 OperationOperation FormatParameter Description Form Floating Number Definition ExampleOperation Command Summary Command DescriptionAUXA? Cmode Command Reference Auxa 1 onResponse DLY seconds Lockout. See also Remote/Local Operation on Snsp Remote/Local Operation on Status, and Fault Registers on Section Accumulated Status, Status, and Fault Registers Condition Mnemonic Bit Position Bit Weight 4096Error Codes Error # Error Identification ExplanationTroubleshooting LEDsCalibration Voltage Program Calibration Procedure Voltage Mode CalibrationSetup VoltageVoltage Readback Calibration Procedure Current Mode Calibration Current Calibration SetupCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc