Xantrex Technology RS232-XPD manual Operation, Format

Page 36

Operation

Command Syntax

Command The device-dependent language for the RS-232 Interface consists of commands and Format and parameters. A command is a one word code which either gives instructions to the Parameters interface or asks for information from the interface. A command may be followed by

one or more parameters, a short code that changes the state of the power supply or the state of the bit register. Table 3.1, “Command Parameters” lists the parameters that affect the command set.

Format:

COMMAND or

COMMAND <parameter> or

COMMAND <parameter>,<parameter>

You can enter commands in upper or lower case lettering.

Example:

MASK FOLD = mask fold

Do not further abbreviate command names or parameters.

Example:

MASK FOLD ≠ MK FOLD

 

MASK FOLD ≠ MASK FD

Use a space between the command and the first parameter. Any number of consecutive spaces is treated as one space. Numeric data may contain leading spaces. Embedded spaces between digits or between a digit and a decimal point are not accepted.

Example:

MASK FOLD = MASK

FOLD

 

VOUT 3.4

= VOUT

3.4

 

VOUT 3.4

≠ VOUT 3.

4

Use commas between parameters in those commands with more than one parameter, and between mnemonic parameters as in the MASK and UNMASK commands. Only one comma is allowed and it may be preceded or followed by any number of spaces.

Example:

MASK CV, OV, FOLD

34

Operating Manual for RS-232 for XPD Series Power Supply

Image 36
Contents RS232-XPD Page Internal RS-232 Interface for XPD 500 Watt Series How do you get service? Phone 604 422 Toll Free North America 800 667 Fax 604 421What does this warranty not cover? Disclaimer Product Information About Your Power Supply Model Number Serial Number Purchased From Purchase DateSafety SupplyMain Sections Manual RevisionsAbout This Manual Contents Contents Features and Specifications DescriptionFeatures and Functions FeaturesFeatures and Specifications Readback FunctionsSpecifications Models 18-30 33-16 60-9 120-4.5Features and Specifications Introduction Initial InspectionInstallation and Configuration Initial InspectionRS-232 Interface Subplate Located on Power Supply Rear Panel RS-232 Interface PCB Basic Setup Procedure Step # Description Action ReferenceFlow Switch Setting Condition CommunicationsBaud Rate XON Switch Setting Condition Jumper Connections RS-232 Connector PinPower Supply DCE Host Computer DTE Pin connector Jumper J10 Connections RS-232 Connector PinSwitch Position Power on results RemoteStartup Condition Default Settings Model Example IsetExample RS-232 Connector J4 Pinouts default configuration RS-232 ConnectionPower Supply Settings Parameter SettingUser Options and Settings 12 OVP Control Mode SelectionHigh OFF LOW User Signals User Signals J21 ConnectorJ21 User Signal Connector Circuit Block Diagram J21 User Cable with Ferrite Block Command Syntax RS-232 OperationOperation FormatParameter Description Form Floating Number Definition ExampleOperation Command Summary Command DescriptionAUXA? Cmode Command Reference Auxa 1 onResponse DLY seconds Lockout. See also Remote/Local Operation on Snsp Remote/Local Operation on Status, and Fault Registers on Section Accumulated Status, Status, and Fault Registers Condition Mnemonic Bit Position Bit Weight 4096Error Codes Error # Error Identification ExplanationTroubleshooting LEDsCalibration Voltage Mode Calibration SetupVoltage Program Calibration Procedure VoltageVoltage Readback Calibration Procedure Current Mode Calibration Current Calibration SetupCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc