Specifications
Electrical Specifications
Input
Input voltage, Maximum Power Point range | 195 to 550 Vdc |
|
|
|
|
|
|
|
|
Absolute maximum array open circuit voltage | 600 Vdc |
|
|
|
|
|
|
|
|
Maximum input current | 16.6 A DC |
|
|
|
|
|
|
|
|
Maximum array short circuit current | 19 A DC |
|
|
|
|
|
|
|
|
Recommended PV array power | Up to 3300 W |
|
|
|
|
|
|
|
|
Reverse polarity protection | Short circuit diode |
|
|
|
|
|
|
|
|
Ground fault protection | GF detection, IDIF > 1 A |
|
|
|
Output |
|
|
|
|
| GT3.0 North American |
|
| GT3.0 European |
|
|
| ||
|
|
|
|
|
Maximum output power | 3000 W AC |
|
| 3000 W AC |
|
|
|
|
|
Nominal output power over rated temp range | 2500 W AC |
|
| 2500 W AC |
|
|
|
|
|
Maximum utility backfeed current | 20 A |
|
| 20 A |
|
|
|
|
|
Nominal output voltage | 240 V |
|
| 230 V |
|
|
|
|
|
Operating range, utility voltage (default)* | 211 to 264 Vac |
|
| 202 to 253 Vac |
|
|
|
|
|
Nominal output frequency | 60 Hz |
|
| 50 Hz |
|
|
|
|
|
Operating range, utility frequency (default)* | 59.3 to 60.5 Hz |
|
| 47.1 to 50.9 Hz |
|
|
|
|
|
Maximum continuous output current | 14.2 A |
|
| 14.9 A |
|
|
|
|
|
Output overcurrent protection | 20 A RMS |
|
| 20 A RMS |
|
|
|
| |
Total Harmonic Distortion (THD) | <5% |
|
| <5% |
|
|
|
| |
Power factor | >0.9 |
|
| >0.9 |
|
|
|
|
|
Utility | Vac, fac as per UL1741 |
|
|
|
|
|
|
| |
Output characteristics |
| Current source | ||
|
|
|
| |
Output current waveform |
|
| Sine wave | |
|
|
|
|
|
*Requires Utility permission and qualified service personnel to change settings.