IBM 9179-MHB, 9117-MMB manual Open Operations Open LED Status

Page 106

v“Activating or deactivating an identify LED using the Advanced System Management Interface” on page 96

Deactivating a system attention LED or partition LED using the management console

You can deactivate a system attention LED or a logical partition LED if you decide that a problem is not a high priority and you decide to repair the problem at a later time. You can do this task from the Hardware Management Console (HMC) or the IBM Systems Director Management Console (SDMC).

If you want to be alerted if another problem occurs, you must deactivate the system attention LED so that it can be activated again if another problem occurs.

To deactivate a system attention LED by using HMC, complete the following steps:

1.In the navigation area, open Systems management.

2.Select the server you are working on by checking the box next to its name.

3.Open Operations.

4.Open LED Status.

5.Select View System Attention. The system attention LED window opens. The selected system and its LED state are displayed in the upper part of the window. The logical partition and its LED state are displayed in the lower part of the window. From the system attention LED window, you can deactivate both the system attention LED and the logical partition LED.

6.Select Deactivate System Attention LED from the Action menu. A confirmation window is displayed that provides the following information:

vA verification that the system attention LED was deactivated.

vAn indication that there still might be open problems within the system.

vAn indication that you cannot activate the system attention LED.

7.Select one of the logical partitions in the lower table, and select Deactivate partition LED from the Partition Operations menu. A confirmation window is displayed that provides the following information:

vA verification that the logical partition LED was deactivated.

vAn indication that there still might be open problems within the logical partition.

vAn indication that you cannot activate the logical partition LED.

To deactivate a system attention LED by using SDMC, complete the following steps:

1.On the Welcome page, under the Resources tab, select the server.

2.Click Actions > Service and Support> Hardware> System Attention LED.

3.Click OK.

Activating or deactivating an identify LED using the management console

You can activate or deactivate an identify LED for components attached to the system from the Hardware Management Console (HMC) or the IBM Systems Director Management Console (SDMC).

The system provides several LEDs that help identify various components, such as enclosures or field-replaceable units (FRUs), in the system. For this reason, they are called identify LEDs.

You can activate or deactivate the following types of identify LEDs:

vIdentify LED for an enclosure If you want to add an adapter to a specific drawer (enclosure), you need to know the machine type, model, and serial number (MTMS) of the drawer. To determine whether you have the correct MTMS for the drawer that needs the new adapter, you can activate the LED for a drawer and verify that the MTMS corresponds to the drawer that requires the new adapter.

94Power Systems: Power supplies for the 9117-MMB or 9179-MHB

Image 106
Contents Power supplies for the 9117-MMB or 9179-MHB Page Power supplies for the 9117-MMB or 9179-MHB Copyright IBM Corporation 2010 Contents Iv Power Systems Power supplies for the 9117-MMB or 9179-MHB Laser safety information World Trade safety informationGerman safety information Laser complianceVi Power Systems Power supplies for the 9117-MMB or 9179-MHB Safety notices Page L003 Power Systems Power supplies for the 9117-MMB or 9179-MHB Whats new in Power supplies MarchRemoving the power supply Related information Before you begin Identifying a failing part Connect the power cable a to the power supply Close the rear rack door Replacing the power supply Power supply LEDs Power supplies FRU fault and identify LED Removing a power supply Fan fault LED and fan identify button Related information Power Systems Power supplies for the 9117-MMB or 9179-MHB Removing a power supply Removing a power supply fan Power supplies Replacing a fan Connecting the power cable to the front of an expansion unit Expansion unit ac power and OCA power LEDs Related information Replacing a fan Replacing a power supply Expansion unit ac power and OCA power LEDs Related information Power Systems Power supplies for the 9117-MMB or 9179-MHB Removing an input power distribution assembly cover Related information Replacing an input power distribution assembly Connecting the power cables at the rear of an expansion unit Replacing an input power distribution assembly Replacing an input power distribution assembly cover Common procedures for installable features Before you beginPower Systems Power supplies for the 9117-MMB or 9179-MHB Power supplies Identifying a part Control panel LEDsControl panel Deactivating the failing-part indicator light Select Display Previous Diagnostic Results and press EnterActivating the indicator light for the failing part Related conceptsActivating the failing-part indicator light Related information Identifying a part by using the Virtual I/O Server Starting the system or logical partition Starting a system that is not managed by an HMC or an SdmcPower supplies Stopping a system or logical partition Stopping a system that is not managed by an HMC or an SdmcStopping a system by using the Hardware Management Console From the Actions menu, select Operations → Power Off Placing the system in the service position Placing the system into the operating position Removing and replacing covers for the 8202-E4B or 8205-E6B Removing the front cover Removing the front cover Removing the front cover Installing the front cover Removing the service access cover Installing the outside service access cover Installing the service access cover Installing the inside service access cover Installing the outside service access cover Removing the power cords for a rack-mounted system Tasks area expand Serviceability → Hardware → MES Tasks Connecting the power cordsVerifying the installed part Did the Resource Repair Action menu appear? No Go to step No. This ends the procedure Sign on with at least service level authority Verifying an installed part by using stand-alone diagnostics Choose Commit Exit to the command line Activating and deactivating LEDs by using the HMC Click Close EventSelect Manage Serviceable Events Viewing serviceable events by using the HMCSelect Actions → View Comments Deactivating a system attention LED or partition LED Activating or deactivating identify LED by using the Sdmc Select Actions → System Status and Health → Event LogPower supplies Select Commit Follow any instructions that are shown Verifying a repair Load the operating systemDid you encounter any problems? Verifying the repair in AIXPerform the following steps Did another Resource Repair Action 801015 display? Yes Power supplies Procedure Verifying the repair in Linux Verifying the repair from the management consoleClosing a service call View Serviceable Event DetailsPower supplies Yes Go to step No Continue with the next step Select the No FRU Replaced for this Serviceable Event option Power Systems Power supplies for the 9117-MMB or 9179-MHB Closing a service call using AIX or Linux System hardware is functioning correctly Select the Diagnostics Routines option Power Systems Power supplies for the 9117-MMB or 9179-MHB Power supplies Yes Continue with the next step No Go to step Click Close Event Is the error class recorded in on page 91? Activating and deactivating LEDs Open Operations Open LED Status Click Actions Service and Support Hardware Identify LED Click Save settings Copyright IBM Corp Class a Notices TrademarksElectronic emission notices Ethernet connection usage restrictionEuropean Community Compliance Statement Industry Canada Compliance StatementAvis de conformité à la réglementation dIndustrie Canada Vcci Statement JapanElectromagnetic Interference EMI Statement Taiwan IBM Taiwan Contact InformationPage Class B Notices Electromagnetic Interference EMI Statement RussiaIndustry Canada Compliance Statement Power Systems Power supplies for the 9117-MMB or 9179-MHB Terms and conditions Power Systems Power supplies for the 9117-MMB or 9179-MHB