IBM 9117-MMB, 9179-MHB manual Click Actions Service and Support Hardware Identify LED

Page 107

vIdentify LED for a FRU associated with a specified enclosure If you want to hook up a cable to a specific I/O adapter, you can activate the LED for the adapter, which is a field replaceable unit (FRU), and then physically check to see where you should hook up the cable. This is especially useful when you have several adapters with open ports.

To activate or deactivate an identify LED for an enclosure or FRU by using the HMC, follow these steps:

1.In the navigation area, open Systems management.

2.Select the server you are working on.

3.Click Operations LED Status Identify LED. The Identify LED, Select Enclosure window opens.

4.To activate or deactivate an identify LED for an enclosure, select an enclosure from the table, and click either Activate LED or Deactivate LED. The associated LED is either turned on or off.

5.To activate or deactivate an identify LED for a FRU, select an enclosure from the table, and then select Selected List FRUs.

6.Select one or more FRUs from the table, and click either Activate LED or Deactivate LED. The associated LED is either turned on or off.

To activate or deactivate an identify LED for an enclosure or FRU by using the SDMC, complete these steps:

1.On the Welcome page, under the Resources tab, select the server.

2.Click Actions > Service and Support> Hardware> Identify LED.

3.To activate or deactivate an identify LED for an enclosure, select an enclosure from the table, and click either Activate LED or Deactivate LED. The associated LED is either turned on or off.

4.To activate or deactivate an identify LED for a FRU, select an enclosure from the table, and then click List FRUs.

5.Select one or more FRUs from the table, and then click either Activate LED or Deactivate LED. The associated LED is either turned on or off.

Deactivating a system attention LED or logical partition LED using the Advanced System Management Interface

You can deactivate a system attention LED or a logical partition LED using the Advanced System Management Interface (ASMI).

The system attention indicator provides a visual signal that the system as a whole requires attention or service. Each system has a single system attention indicator. When an event occurs that either needs your intervention or that of service and support, the system attention indicator lights continuously. The system attention indicator is turned on when an entry is made in the service processor error log. The error entry is transmitted to the system error log and the operating system error log.

To perform this operation, your authority level must be one of the following levels:

vAdministrator

vAuthorized service provider

To turn off the system attention indicator, do the following steps:

1.On the ASMI Welcome pane, specify your user ID and password, and click Log In.

2.In the navigation area, expand System Configuration Service Indicators System Attention Indicator.

3.In the right pane, click Turn off system attention indicator. If the attempt is unsuccessful, an error message is displayed.

Power supplies 95

Image 107
Contents Power supplies for the 9117-MMB or 9179-MHB Page Power supplies for the 9117-MMB or 9179-MHB Copyright IBM Corporation 2010 Contents Iv Power Systems Power supplies for the 9117-MMB or 9179-MHB Laser compliance World Trade safety informationGerman safety information Laser safety informationVi Power Systems Power supplies for the 9117-MMB or 9179-MHB Safety notices Page L003 Power Systems Power supplies for the 9117-MMB or 9179-MHB March Whats new in Power suppliesRemoving the power supply Related information Before you begin Identifying a failing part Connect the power cable a to the power supply Close the rear rack door Replacing the power supply Power supply LEDs Power supplies FRU fault and identify LED Removing a power supply Fan fault LED and fan identify button Related information Power Systems Power supplies for the 9117-MMB or 9179-MHB Removing a power supply Removing a power supply fan Power supplies Replacing a fan Connecting the power cable to the front of an expansion unit Expansion unit ac power and OCA power LEDs Related information Replacing a fan Replacing a power supply Expansion unit ac power and OCA power LEDs Related information Power Systems Power supplies for the 9117-MMB or 9179-MHB Removing an input power distribution assembly cover Related information Replacing an input power distribution assembly Connecting the power cables at the rear of an expansion unit Replacing an input power distribution assembly Replacing an input power distribution assembly cover Before you begin Common procedures for installable featuresPower Systems Power supplies for the 9117-MMB or 9179-MHB Power supplies Control panel LEDs Identifying a partControl panel Related concepts Select Display Previous Diagnostic Results and press EnterActivating the indicator light for the failing part Deactivating the failing-part indicator lightActivating the failing-part indicator light Related information Identifying a part by using the Virtual I/O Server Starting a system that is not managed by an HMC or an Sdmc Starting the system or logical partitionPower supplies Stopping a system that is not managed by an HMC or an Sdmc Stopping a system or logical partitionStopping a system by using the Hardware Management Console From the Actions menu, select Operations → Power Off Placing the system in the service position Placing the system into the operating position Removing and replacing covers for the 8202-E4B or 8205-E6B Removing the front cover Removing the front cover Removing the front cover Installing the front cover Removing the service access cover Installing the outside service access cover Installing the service access cover Installing the inside service access cover Installing the outside service access cover Removing the power cords for a rack-mounted system Connecting the power cords Tasks area expand Serviceability → Hardware → MES TasksVerifying the installed part Did the Resource Repair Action menu appear? No Go to step No. This ends the procedure Sign on with at least service level authority Verifying an installed part by using stand-alone diagnostics Choose Commit Exit to the command line Click Close Event Activating and deactivating LEDs by using the HMCSelect Actions → View Comments Viewing serviceable events by using the HMCSelect Manage Serviceable Events Deactivating a system attention LED or partition LED Select Actions → System Status and Health → Event Log Activating or deactivating identify LED by using the SdmcPower supplies Select Commit Follow any instructions that are shown Load the operating system Verifying a repairVerifying the repair in AIX Did you encounter any problems?Perform the following steps Did another Resource Repair Action 801015 display? Yes Power supplies Procedure Verifying the repair from the management console Verifying the repair in LinuxView Serviceable Event Details Closing a service callPower supplies Yes Go to step No Continue with the next step Select the No FRU Replaced for this Serviceable Event option Power Systems Power supplies for the 9117-MMB or 9179-MHB Closing a service call using AIX or Linux System hardware is functioning correctly Select the Diagnostics Routines option Power Systems Power supplies for the 9117-MMB or 9179-MHB Power supplies Yes Continue with the next step No Go to step Click Close Event Is the error class recorded in on page 91? Activating and deactivating LEDs Open Operations Open LED Status Click Actions Service and Support Hardware Identify LED Click Save settings Copyright IBM Corp Ethernet connection usage restriction TrademarksElectronic emission notices Class a NoticesVcci Statement Japan Industry Canada Compliance StatementAvis de conformité à la réglementation dIndustrie Canada European Community Compliance StatementIBM Taiwan Contact Information Electromagnetic Interference EMI Statement TaiwanPage Electromagnetic Interference EMI Statement Russia Class B NoticesIndustry Canada Compliance Statement Power Systems Power supplies for the 9117-MMB or 9179-MHB Terms and conditions Power Systems Power supplies for the 9117-MMB or 9179-MHB