Fujitsu MAT3073NC/NP, MAT3300NC/NP, MAT3147NC/NP manual Error rate, Reliability, Mtbf=

Page 31

(*4) At power-off state after installation

Vibration displacement should be less than 2.5 mm.

(*5) Input voltages are specified at the drive connector side, during drive ready state.

(*6) The terminator power pin (SCSI connector) which supplies power to other terminators is not used (See Section 4.3).

(*7) High frequency noise (over 20 MHz) is less than 100 mVp-p.

2.1.4Error rate

Errors detected during initialization and replaced by alternate block assignments are not included in the error rate. Data blocks to be accessed should be distributed over the disk medium equally.

(1)Unrecoverable error rate

Errors which cannot be recovered within 63 retries and ECC correction should not exceed 1 per 1015 bits.

CAUTION

Data loss

The drive adopts Reed-Solomon code for ECC. The sector-data is divided into 3 interleaving sectors, and ECC is performed in each sector where the maximum number of errors (up to 9 byte) can be corrected. [Total maximum byte: 9 byte 3 ( interleave) = 27 byte] If the error of read sector keeps allowable error byte number, correction is performed. However, if error byte exceeds its allowable number, correction may not be performed properly.

(2)Positioning error rate

Positioning errors which can be recovered by one retry should be 10 or less per 108 seeks.

2.1.5Reliability

(1)Mean Time Between Failures (MTBF)

MTBF of the IDD during its life time is 1,2000,000 hours (operating: 24 hours/day, 7 days/week

average DE surface temperature: 50°C or less).

Note:

The MTBF is defined as:

Operating time (hours) at all field sites

MTBF=

The number of equipment failures from all field sites

C141-E201

2-5

Image 31
Contents C141-E201-01EN For Safe Operation Revision Record Related Standards General Description PrefaceConventions for Alert Messages Important Alert Messages Important Alert ItemsTask Alert message Mounting Installation Manual Organization Product Maintenance This page is intentionally left blank Contents Diagnostics and Maintenance IN-1 Appendix B Connector Signal AllocationFigures Page Tables General Description Standard Features Hardware Structure System ConfigurationStandard Features C141-E201 Page Page NC model drives outer view Page System configuration LUN Scsi IDThis page is intentionally left blank Model names and order numbers SpecificationsHardware Specifications Scsi Function Specifications Hardware Specifications Model name and order numberScsi Function specificationsMAT3300NC/NP MAT3147NC/NP MAT3073NC/NP 32/34 MeeprmlPage Environmental/power requirements Environmental specificationsIops Reliability Error rateMTBF= Temperature is 60C or less Shows the Scsi functions provided with the IDD This page is intentionally left blank Data Space Cylinder configurationData Format Data Space Logical Data Block Addressing Defect ManagementSA0 Alternate spare area Spare area in cell Track format Sector format Track skew/head skewPage MAT3300NC/NP Format capacityPage Alternate block allocation Defect Management Defect listPage Alternate block allocation by Format Unit command Alternate block allocation by Reassign Blocks command Format Unit Write Write ExtendC141-E201 This page is intentionally left blank Mounting Requirements External dimensions Installation RequirementsNC external dimensions NP external dimensions IDD orientations MountingHoles for HDC Surface temperature check pointMPU Service clearance area Spin-up current waveform +12 VDC 10 Power on/off sequence Delay time of spindle motor starting 13 NC connectors location 14 SCA2 type 16-bit Scsi connector 15 NP connectors and terminals location 2 68 pin connector type 16-bit Scsi model NP model16 68 pin type 16-bit Scsi interface connector GND EsidLED Open20 16-bit Scsi ID external input IDD 21 Output signal for external LED 22 Scsi cables connection Recommended components for connection Cable connector requirementsGND LED External operator panel on NP model drives onlyLED ID0 ID1 ID2 ID3 C141-E201 Installation Page Connections Scsi bus connections 1 Pin Scsi ID #15 CN2 setting terminal on NP models only Scsi ID settingScsi Setting Scsi terminator power supply NP model Each mode settingMotor start mode setting Setting of the Scsi interface operation mode NP model Write protect setting NP modelSetting the bus width of the Scsi interface NP model Default mode settings by Change Definition command Mode settingsSCSI-3 Scsi ID CN2 Setting check list NP model onlyMounting procedures Mounting Drives Check before mountingConnecting Cables Remark Checking Scsi connection Checking the Scsi connection a Checking the Scsi connection B Formatting Page Setting parameters Arre AwreArre Awre PER Xffff DiscXxxx Read/write This page is intentionally left blank Diagnostics Self-diagnostics Diagnostics and MaintenanceSelf-diagnostic functions Page Operation of self-diagnostics Test programs Maintenance Information Precautions Maintenance requirements C141-E201 Maintenance levels Revision label Revision numbersTests Indicating revision numbers Tools and test equipmentTest flowchart Operation Check Initial seek operation check Diagnostic testOperation test Troubleshooting with disk drive replacement in the field System-level field troubleshooting Disk drive troubleshooting Troubleshooting at the repair siteFinding possibly faulty parts Troubleshooting with parts replacement in the factoryError Analysis Information Collection Sense Data Analysis Error AnalysisError Analysis Information Collection Sense data LSB ILISksv Definition of sense data Sense data 3-0C-03, 4-40-xx, and 4-C4-xx Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorSetting Terminals on NP model only Appendix a Setting TerminalsScsi ID Appendix B Connector Signal Allocation Diffsns Pcrca GND Diffsns Termpwr DBP1GND ATN BSY ACK RST MSG SEL REQ This page is intentionally left blank Bcrc IndexCN1 ECC Mode SELECT/MODE SelectPAD Programmable multi-segment data buffer This page is intentionally left blank Comment Form This page is intentionally left blankw
Related manuals
Manual 2 pages 4.47 Kb