Fujitsu MAT3147NC/NP manual Each mode setting, Setting Scsi terminator power supply NP model

Page 80

5.3.2Each mode setting

(1)Setting terminator power supply

Refer to Table 5.2 for controlling the supply of power from the drive to the SCSI terminator power source (TERMPOW).

For information on NP model, refer to Figures 5.2 and 5.3.

Table 5.2 Setting SCSI terminator power supply (NP model)

Supply on/off of SCSI terminator power from

CN2 23-24

IDD

 

 

 

Supply off

Open

 

 

Supply on

Short (*1)

 

 

*1. Set at factory shipment.

 

For NC model, the function of the terminator power supply setting is not supported.

(2)Motor start mode

Set how to control the starting of the IDD spindle motor according to Table 5.3. This setting only determines the operation mode when the power supply is turned on or the microcode is downloaded. In both modes, stopping or restarting the spindle motor can be controlled by specifying the START/STOP UNIT command.

Table 5.3

Motor start mode setting

 

 

 

 

 

 

 

Start timing of the spindle motor

 

NC model (*3)

NP model

 

 

 

 

 

 

CN1 38

 

CN1 78

CN2 11-12

 

 

 

 

 

 

 

 

Starting of the motor is controlled with the

Short

 

Open or Short

Open

START/STOP UNIT command.

 

 

 

 

 

 

 

 

 

 

 

 

The motor is started immediately after the

 

 

 

 

power supply is turned on or after the

 

Open

 

Open

Short (*1)

microcode is downloaded.

 

 

 

 

 

 

 

 

 

 

The motor is started after the elapse of a delay

 

 

 

 

time that is based on the SCSI ID. The delay

 

 

 

 

time is provided immediately after the power

Open

 

Short

(*2)

supply is turned on or after the microprogram is

 

 

 

 

downloaded.

 

 

 

 

 

 

 

 

 

 

 

*1. Set at factory shipment.

*2. For NP model, delay starting of spindle motor is supported by the CHANGE DEFINITION command only.

*3. To set the setting terminals on NC models to short, apply voltage ranging between-0.3 V and

0.8V to the setting terminals externally. To set the setting terminals on NC models to open, apply voltage ranging between 2.0 V and 5.5 V to the setting terminals from an external source.

Refer to Chapter 3 of the SCSI Logical Interface Specifications for details of the START/STOP UNIT command.

5-8

C141-E201

Image 80
Contents C141-E201-01EN For Safe Operation Revision Record Related Standards Preface General DescriptionConventions for Alert Messages Important Alert Items Important Alert MessagesTask Alert message Mounting Installation Manual Organization Product Maintenance This page is intentionally left blank Contents Diagnostics and Maintenance Appendix B Connector Signal Allocation IN-1Figures Page Tables Standard Features Hardware Structure System Configuration General DescriptionStandard Features C141-E201 Page Page NC model drives outer view Page System configuration Scsi ID LUNThis page is intentionally left blank Specifications Hardware Specifications Scsi Function SpecificationsHardware Specifications Model name and order number Model names and order numbersFunction specifications MAT3300NC/NP MAT3147NC/NP MAT3073NC/NP32/34 Meeprml ScsiPage Iops Environmental specificationsEnvironmental/power requirements MTBF= Error rateReliability Temperature is 60C or less Shows the Scsi functions provided with the IDD This page is intentionally left blank Cylinder configuration Data FormatData Space Logical Data Block Addressing Defect Management Data SpaceSA0 Alternate spare area Spare area in cell Track format Track skew/head skew Sector formatPage Format capacity MAT3300NC/NPPage Defect Management Defect list Alternate block allocationPage Alternate block allocation by Format Unit command Alternate block allocation by Reassign Blocks command Write Write Extend Format UnitC141-E201 This page is intentionally left blank Installation Requirements Mounting Requirements External dimensionsNC external dimensions NP external dimensions Mounting IDD orientationsHoles for MPU Surface temperature check pointHDC Service clearance area Spin-up current waveform +12 VDC 10 Power on/off sequence Delay time of spindle motor starting 13 NC connectors location 14 SCA2 type 16-bit Scsi connector 2 68 pin connector type 16-bit Scsi model NP model 15 NP connectors and terminals location16 68 pin type 16-bit Scsi interface connector Esid LEDOpen GND20 16-bit Scsi ID external input IDD 21 Output signal for external LED 22 Scsi cables connection Cable connector requirements Recommended components for connectionLED ID0 ID1 ID2 ID3 External operator panel on NP model drives onlyGND LED C141-E201 Installation Page Connections Scsi bus connections 1 Pin CN2 setting terminal on NP models only Scsi ID setting Scsi ID #15Scsi Motor start mode setting Each mode settingSetting Scsi terminator power supply NP model Setting the bus width of the Scsi interface NP model Write protect setting NP modelSetting of the Scsi interface operation mode NP model SCSI-3 Mode settingsDefault mode settings by Change Definition command Setting check list NP model only Mounting proceduresMounting Drives Check before mounting Scsi ID CN2Connecting Cables Remark Checking Scsi connection Checking the Scsi connection a Checking the Scsi connection B Formatting Page Setting parameters Awre ArreArre Awre PER Xxxx DiscXffff Read/write This page is intentionally left blank Self-diagnostic functions Diagnostics and MaintenanceDiagnostics Self-diagnostics Page Operation of self-diagnostics Test programs Maintenance Information Precautions Maintenance requirements C141-E201 Maintenance levels Revision numbers Revision labelIndicating revision numbers Tools and test equipment TestsTest flowchart Operation test Diagnostic testOperation Check Initial seek operation check Troubleshooting with disk drive replacement in the field System-level field troubleshooting Troubleshooting at the repair site Disk drive troubleshootingTroubleshooting with parts replacement in the factory Finding possibly faulty partsError Analysis Information Collection Sense data Error AnalysisError Analysis Information Collection Sense Data Analysis Sksv ILILSB Definition of sense data Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error Sense data 3-0C-03, 4-40-xx, and 4-C4-xxAppendix a Setting Terminals Setting Terminals on NP model onlyScsi ID Appendix B Connector Signal Allocation Diffsns GND ATN BSY ACK RST MSG SEL REQ DBP1Pcrca GND Diffsns Termpwr This page is intentionally left blank CN1 IndexBcrc PAD Mode SELECT/MODE SelectECC Programmable multi-segment data buffer This page is intentionally left blank Comment Form This page is intentionally left blankw