Fujitsu MAT3073NC/NP, MAT3300NC/NP, MAT3147NC/NP manual C141-E201

Page 19

Note:

The maximum data transfer rate in asynchronous mode may be limited by the response time of initiator and the length of SCSI bus length. The maximum data transfer rate in synchronous mode may be limited by the cable length, transmission characteristics of the SCSI bus and the connected SCSI device number.

(5)Continuous block processing

The addressing method of data blocks is logical block address. The initiator can access data by specifying block number in a logically continuous data space without concerning the physical structure of the track or cylinder boundaries.

The continuous processing up to [64K-1] blocks in a command can be achieved, and IDD can perform continuous read/write operation when processing data blocks on several tracks or cylinder.

(6)Programmable multi-segment data buffer

The data buffer is 8M bytes. Data is transferred between SCSI bus and disk media through this data buffer. This feature provides the suitable usage environment for users.

Since the initiator can control the disconnect/reconnect timing on the SCSI bus by specifying the condition of stored data to the data buffer or empty condition of the data buffer, the initiator can perform the effective input/output operations with utilizing high data transfer capability of the SCSI bus regardless of actual data transfer rate of the disk drive.

(7)Cache feature

After executing the READ command, the IDD reads automatically and stores (prefetches) the subsequent data blocks into the data buffer (Read-ahead caching).

The high speed sequential data access can be achieved by transferring the data from the data buffer without reaccessing the disk in case the subsequent command requests the prefetched data blocks.

The write cache feature is supported. When this feature is enabled, the status report is issued without waiting for completion of write processing to disk media, thereby enabling high speed write processing.

IMPORTANT

When Write cache is enabled, you should ensure that the cashed data is surely flushed to the disc media before you turn off the drive's power.

To ensure it, you should issue either the SYNCHRONIZE CASHE command or the STOP UNIT command with specifying “0” to the Immediate bit and then confirm that the command is surely terminated with the GOOD STATUS.

C141-E201

1-3

Image 19
Contents C141-E201-01EN For Safe Operation Revision Record Related Standards General Description PrefaceConventions for Alert Messages Important Alert Messages Important Alert ItemsTask Alert message Mounting Installation Manual Organization Product Maintenance This page is intentionally left blank Contents Diagnostics and Maintenance IN-1 Appendix B Connector Signal AllocationFigures Page Tables General Description Standard Features Hardware Structure System ConfigurationStandard Features C141-E201 Page Page NC model drives outer view Page System configuration LUN Scsi IDThis page is intentionally left blank Model names and order numbers SpecificationsHardware Specifications Scsi Function Specifications Hardware Specifications Model name and order numberScsi Function specificationsMAT3300NC/NP MAT3147NC/NP MAT3073NC/NP 32/34 MeeprmlPage Environmental/power requirements Environmental specificationsIops Reliability Error rateMTBF= Temperature is 60C or less Shows the Scsi functions provided with the IDD This page is intentionally left blank Data Space Cylinder configurationData Format Data Space Logical Data Block Addressing Defect ManagementSA0 Alternate spare area Spare area in cell Track format Sector format Track skew/head skewPage MAT3300NC/NP Format capacityPage Alternate block allocation Defect Management Defect listPage Alternate block allocation by Format Unit command Alternate block allocation by Reassign Blocks command Format Unit Write Write ExtendC141-E201 This page is intentionally left blank Mounting Requirements External dimensions Installation RequirementsNC external dimensions NP external dimensions IDD orientations MountingHoles for HDC Surface temperature check pointMPU Service clearance area Spin-up current waveform +12 VDC 10 Power on/off sequence Delay time of spindle motor starting 13 NC connectors location 14 SCA2 type 16-bit Scsi connector 15 NP connectors and terminals location 2 68 pin connector type 16-bit Scsi model NP model16 68 pin type 16-bit Scsi interface connector GND EsidLED Open20 16-bit Scsi ID external input IDD 21 Output signal for external LED 22 Scsi cables connection Recommended components for connection Cable connector requirementsGND LED External operator panel on NP model drives onlyLED ID0 ID1 ID2 ID3 C141-E201 Installation Page Connections Scsi bus connections 1 Pin Scsi ID #15 CN2 setting terminal on NP models only Scsi ID settingScsi Setting Scsi terminator power supply NP model Each mode settingMotor start mode setting Setting of the Scsi interface operation mode NP model Write protect setting NP modelSetting the bus width of the Scsi interface NP model Default mode settings by Change Definition command Mode settingsSCSI-3 Scsi ID CN2 Setting check list NP model onlyMounting procedures Mounting Drives Check before mountingConnecting Cables Remark Checking Scsi connection Checking the Scsi connection a Checking the Scsi connection B Formatting Page Setting parameters Arre AwreArre Awre PER Xffff DiscXxxx Read/write This page is intentionally left blank Diagnostics Self-diagnostics Diagnostics and MaintenanceSelf-diagnostic functions Page Operation of self-diagnostics Test programs Maintenance Information Precautions Maintenance requirements C141-E201 Maintenance levels Revision label Revision numbersTests Indicating revision numbers Tools and test equipmentTest flowchart Operation Check Initial seek operation check Diagnostic testOperation test Troubleshooting with disk drive replacement in the field System-level field troubleshooting Disk drive troubleshooting Troubleshooting at the repair siteFinding possibly faulty parts Troubleshooting with parts replacement in the factoryError Analysis Information Collection Sense Data Analysis Error AnalysisError Analysis Information Collection Sense data LSB ILISksv Definition of sense data Sense data 3-0C-03, 4-40-xx, and 4-C4-xx Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorSetting Terminals on NP model only Appendix a Setting TerminalsScsi ID Appendix B Connector Signal Allocation Diffsns Pcrca GND Diffsns Termpwr DBP1GND ATN BSY ACK RST MSG SEL REQ This page is intentionally left blank Bcrc IndexCN1 ECC Mode SELECT/MODE SelectPAD Programmable multi-segment data buffer This page is intentionally left blank Comment Form This page is intentionally left blankw
Related manuals
Manual 2 pages 4.47 Kb