Fujitsu 600C manual Scsi Cable Connection

Page 17

The devices linked to the SCSI interface are daisy-chained with one another. A terminator is attached to the ends of the interface cable. User can buy the SCSI cable in computer stores. The specifications of the SCSI cable is as shown below.

Name:

SCSI Cable

Cable Specification 50 pins to 25 or 50 pins, shielded Amphenol

Cable Length:

Less than or equal to 6 meters.

3.4.1SCSI Cable Connection

There are two configurations for the connection.

Configuration I: The number of devices attached to the SCSI bus (including the host PC) is three. The scanner is located in the middle of the connection, as shown below.

Host PC

Terminator

Scanner

Set terminator switch at “off” position

SCSI device

Terminator

1.Set scanner’s SCSI terminator switch off.

2.Plug one end of the SCSI cable into the SCSI connector of the host PC, and the other end of the cable to the scanner.

3.Plug one end of the SCSI cable into the SCSI connector of the third device, and the other end of the cable to the other scanner.

3-5

Image 17
Contents Version Page Table of Contents Diagnostics Group 3 error flowchart no paper in ADF paper tray Page General GeneralSystem Block Diagram Outer View Device ConfigurationComponents Functional Specifications Remarks Functional SpecificationsEnvironmental Specifications Remarks Environmental SpecificationsRemoving the Shipping Bracket OperationRemove the shipping retainer Fasten the shipping retainer Indication Panel Power On/OffNames and functions of the indicators Setting the Scsi ID and Connecting the Interface CableScsi ID setting Name Color FunctionScsi Cable Connection Position Paper Size Paper SpecificationsPaper conditions 2.1 ADFItems to avoid FIatbedADF readable area Readable areaFlatbed Document Setting MethodWhen the document size is of letter/A4 size or smaller 2 ADF When the document is a thick bookSetting the ADF paper chute Placing the document on the ADF paper chute Placing the documents on the ADF paper chuteSeparating the sheets for easy feeding Angling the document sheetsCleaning the document cover and the document glass CleaningCleaning inside the ADF Page Interface ∙ Busy ∙ Check Condition ∙ Good ∙ Reservation Conflict Connection Physical SpecificationsSpecifications Physical Specification1SCSI physical specifications TerminationPin assignments Signal Name Pin NumberSystem configuration System configurationScsi Bus Addresses of Scsi devices2Bus signals Bus signals3Bus phases vs. signal drive sources 1/2 Bus signal drive conditionsOr connection Nonor connection Bus PhasesMethod of driving the interface signal 5Signal delay times definition Time Definition Time Definition BUS Free phaseSignal delay times definition Arbitration phase BSY Scsi SEL Selection phase DB7 to 9,P Transfer Direction Information Transfer phasesInformation Transfer phase type Phase Asynchronous transfer from target to initiator Asynchronous information transferAsynchronous transler from initiator to target Control byte is not supported CommandsRelative addressing is not supported Commands Reserve Unit commandOperation Command Code hex Description Bit and field described as Reserved areTpid third party device ID Byte Reserve Unit command Command phase initiator Õ targetTP third party Byte TP third party Byte Release Unit commandRelease Unit command Command phase initiator → target Inquiry command Command phase initiator → target Inquiry command10 Inquiry command Step Bus phase Initiator operation Target operationCAllocation length Byte Evpd enable vital product data ByteCode Byte Aenc Inquiry data Data in phase target → initiatorADF mode Byte 24, bit SftRst Soft Reset ByteColor mode Byte 24, bit 6 to ISO version, Ecma version, Ansi approved version Byte11 Request Sense command Request Sense commandRequest Sense command Command phase initiator → target Error code Byte Sense data Data EN phase target → initiatorAllocation length Byte Valid ByteFM file mark Byte ILI incorrect length indicator ByteEOM end of medium Byte Sense key ByteCommand-specific information bytes Bytes 8 to B Send Diagnostic commandSense Additional Description Sense codeSlftst selftest Byte Send Diagnostic command Command phase initiator → targetPF page format Byte Results of self-test Test Unit Ready commandContents of self-test Acknowledgment Test Unit Ready command Command phase initiator → targetSET Window command Command phase initiator → target SET Window commandHeader Window date Data OUT phase initiator → targetTransfer Length Bytes 6 to Window descriptor block Window identifier Byte Y resolution XR, YR Bytes 2 to 3 and 4 toAuto Byte Upper left X,YULX, ULY Bytes 6 to 9, a to DRemarks Brightness ByteRIF reverse image format Byte 1D, bit Bit per pixel Byte 1ABit ordering Bytes 1E to 1F Halftone pattern Bytes lB to 1C lB reserved7.4 B&W Scanning Vender unique parameters Update of ScanPartner 600C OEM manualCompression type, argument Bytes 20 to 18 Vender unique parameters byte 28 and laterPage 19 Vendor unique parameters byte 28 and later Color Scanning Vender unique parametersADF Byte 2A, Bit Source Byte 2A, BitShadow value Byte 2C Highlight value Byte 2BLine width Byte 2D to 2E Line count Byte 2F toObject Position command Bit Object Position command Command phase initator → targetPosition type Byte Load object Unload objectCount Bytes 2 to NormalADF sequence Read commandStep Bus phase Initiator operation Target operation Data type code Byte Read command Command phase initiator → targetData type qualifier Bytes 4 to Transfer length TL Bytes 6 toImage data Data Type Code = Data in phase target → initiatorFor binary data Pixel size data Data Type Code =Scan Command phase initiator → target Scan commandCode Status of unit Status Status phase target initiatorATN detection Phase ATN detection timingMessages Message Command Complete X00 Message in phase target → initiatorMessage types ATN detection phase Action Abort X06 Message OUT phase initiator → targetMessage Reject X07 Message IN/OUT phase initiator → target BUS Device Reset X0C Message OUT phase initiator → target No Operation X08 Message OUT phase initiator → targetPhase when ATN is detected Action Message rejected ActionIdendify X80 to XFF Message OUT phase initiator → target Initial sequence Command SequenceRead sequence for B&W mode Read command sequenceRead sequence Single ReadMultiple Read Status Transition of Logical Unit Sense key Error TableItems for Specifying Window Page Online diagnostics Online diagnosticsReady LED Paper Jam LED Error indication Offline diagnostics results Offline diagnosticsGroup 2 error flowchart Flatbed/ADF motor Diagnostic flowchartsGroup 1 error flowchart Lamp assembly Group 3 error flowchart paper in ADF paper tray Group 3 error flowchart no paper in ADF paper tray