Fujitsu 600C manual 5Signal delay times definition Time Definition

Page 38

The signal delay times for each bus phase are defined as follows-

Table 4-5Signal delay times definition

No.

Item

Time

Definition

 

 

 

 

 

 

 

 

1

Arbitration

2.4 æs

The minimum time an SCSI device shall wait from

 

delay

 

asserting BSY for arbitration until the DATA BUS can

 

 

 

be examined to see if arbitration has been won. There is

 

 

 

no maximum time.

2

Assertion

90 ns

The minimum time that a target shall assert REQ (or

 

period

 

REQB) while using synchronous data transfers. Also,

 

 

 

the minimum time that an initiator shall assert ACK

 

 

 

while using synchronous data transfers.

3

Bus Clear

800 ns

The maximum time for an SCSI device to stop driving

 

delay

 

all bus signals after: (1) The BUS FREE phase is

 

 

 

detected (BSY and SEL both false for a bus settle delay)

 

 

 

(2) SEL is received from another SCS] device during the

 

 

 

ARBITRATION phase (3) The transition of RST to true.

 

 

 

For the first condition listed. the maximum time for an

 

 

 

SCSI device to clear the bus is 1200 nanoseconds from

 

 

 

BSY and SEL first becoming both false. If an SCSI

 

 

 

device requires more than a bus settle delay to detect

 

 

 

BUS FREE phase, it shall clear the bus within a bus

 

 

 

clear delay minus the excess time

4

Bus free delay

800 ns

The minimum time that an SCSI device shall wait from

 

 

 

its detection of the BUS FREE phase (BSY and SEL

 

 

 

both false

5

Bus set delay

1.8 _s

The maximum time for an SCSI device to assert BSY

 

 

 

and its SCSI ID bit on the DATA BUS after it detects

 

 

 

BUS FREE phase (BSY and SEL both false for a bus

 

 

 

settle delay) for the purpose of entering the

 

 

 

ARBITRATION phase

6

Bus settle

400 ns

The minimum time to wait for the bus to settle after

 

delay

 

changing certain control signals as called out in the

 

 

 

protocol definitions

7

Cable skew

10 ns

The maximum difference in propagation time allowed

 

delay

 

between any two SCSI bus signals measured between

 

 

 

any two SCSI devices.

8

Data release

400 ns

The maximum time for an initiator to release the DATA

 

delay

 

BUS signals following the transition of the I/O signal

 

 

 

from false to true.

9

Deskew delay

45 ns

The minimum time required for deskew of certain

 

 

 

signals

10

Disconnection

200 æs

The minimum time that a target shall wait after

 

 

 

releasing BSY before participating in an

 

 

 

ARBITRATION phase when honoring a DISCONNECT

 

 

 

message from the initiator

4-10

Image 38
Contents Version Page Table of Contents Diagnostics Group 3 error flowchart no paper in ADF paper tray Page General GeneralSystem Block Diagram Device Configuration Outer ViewComponents Functional Specifications Functional Specifications RemarksEnvironmental Specifications Environmental Specifications RemarksOperation Removing the Shipping BracketRemove the shipping retainer Fasten the shipping retainer Power On/Off Indication PanelScsi ID setting Setting the Scsi ID and Connecting the Interface CableNames and functions of the indicators Name Color FunctionScsi Cable Connection Position Paper conditions Paper SpecificationsPaper Size 2.1 ADFFIatbed Items to avoidReadable area ADF readable areaFlatbed Document Setting MethodWhen the document size is of letter/A4 size or smaller 2 ADF When the document is a thick bookSetting the ADF paper chute Placing the documents on the ADF paper chute Placing the document on the ADF paper chuteAngling the document sheets Separating the sheets for easy feedingCleaning Cleaning the document cover and the document glassCleaning inside the ADF Page Interface ∙ Busy ∙ Check Condition ∙ Good ∙ Reservation Conflict Physical Specifications Connection1SCSI physical specifications Physical SpecificationSpecifications TerminationSignal Name Pin Number Pin assignmentsScsi Bus System configurationSystem configuration Addresses of Scsi devicesBus signals 2Bus signalsBus signal drive conditions 3Bus phases vs. signal drive sources 1/2Or connection Nonor connection Bus PhasesMethod of driving the interface signal 5Signal delay times definition Time Definition Time Definition BUS Free phaseSignal delay times definition Arbitration phase BSY Scsi SEL Selection phase DB7 to 9,P Transfer Direction Information Transfer phasesInformation Transfer phase type Phase Asynchronous information transfer Asynchronous transfer from target to initiatorAsynchronous transler from initiator to target Control byte is not supported CommandsRelative addressing is not supported Operation Command Code hex Description Reserve Unit commandCommands Bit and field described as Reserved areTpid third party device ID Byte Reserve Unit command Command phase initiator Õ targetTP third party Byte TP third party Byte Release Unit commandRelease Unit command Command phase initiator → target 10 Inquiry command Inquiry commandInquiry command Command phase initiator → target Step Bus phase Initiator operation Target operationCAllocation length Byte Evpd enable vital product data ByteCode Byte Inquiry data Data in phase target → initiator AencColor mode Byte 24, bit 6 to SftRst Soft Reset ByteADF mode Byte 24, bit ISO version, Ecma version, Ansi approved version Byte11 Request Sense command Request Sense commandRequest Sense command Command phase initiator → target Allocation length Byte Sense data Data EN phase target → initiatorError code Byte Valid ByteEOM end of medium Byte ILI incorrect length indicator ByteFM file mark Byte Sense key ByteSense Additional Description Send Diagnostic commandCommand-specific information bytes Bytes 8 to B Sense codeSlftst selftest Byte Send Diagnostic command Command phase initiator → targetPF page format Byte Results of self-test Test Unit Ready commandContents of self-test Test Unit Ready command Command phase initiator → target AcknowledgmentSET Window command SET Window command Command phase initiator → targetHeader Window date Data OUT phase initiator → targetTransfer Length Bytes 6 to Window descriptor block Auto Byte Y resolution XR, YR Bytes 2 to 3 and 4 toWindow identifier Byte Upper left X,YULX, ULY Bytes 6 to 9, a to DBrightness Byte RemarksBit ordering Bytes 1E to 1F Bit per pixel Byte 1ARIF reverse image format Byte 1D, bit Halftone pattern Bytes lB to 1C lB reservedCompression type, argument Bytes 20 to Update of ScanPartner 600C OEM manual7.4 B&W Scanning Vender unique parameters 18 Vender unique parameters byte 28 and laterPage ADF Byte 2A, Bit Color Scanning Vender unique parameters19 Vendor unique parameters byte 28 and later Source Byte 2A, BitLine width Byte 2D to 2E Highlight value Byte 2BShadow value Byte 2C Line count Byte 2F toObject Position command Bit Object Position command Command phase initator → targetPosition type Byte Count Bytes 2 to Unload objectLoad object NormalADF sequence Read commandStep Bus phase Initiator operation Target operation Data type qualifier Bytes 4 to Read command Command phase initiator → targetData type code Byte Transfer length TL Bytes 6 toFor binary data Data in phase target → initiatorImage data Data Type Code = Pixel size data Data Type Code =Scan command Scan Command phase initiator → targetStatus Status phase target initiator Code Status of unitATN detection Phase ATN detection timingMessages Message Command Complete X00 Message in phase target → initiatorMessage types ATN detection phase Action Abort X06 Message OUT phase initiator → targetMessage Reject X07 Message IN/OUT phase initiator → target Phase when ATN is detected Action No Operation X08 Message OUT phase initiator → targetBUS Device Reset X0C Message OUT phase initiator → target Message rejected ActionIdendify X80 to XFF Message OUT phase initiator → target Command Sequence Initial sequenceRead sequence Read command sequenceRead sequence for B&W mode Single ReadMultiple Read Status Transition of Logical Unit Error Table Sense keyItems for Specifying Window Page Online diagnostics Online diagnosticsReady LED Paper Jam LED Error indication Offline diagnostics Offline diagnostics resultsGroup 2 error flowchart Flatbed/ADF motor Diagnostic flowchartsGroup 1 error flowchart Lamp assembly Group 3 error flowchart paper in ADF paper tray Group 3 error flowchart no paper in ADF paper tray