Fujitsu 600C manual Pin assignments, Signal Name Pin Number

Page 33

4.1.4Pin assignments

Physical Specifications

Signal Name

Pin Number

Signal Name

 

 

 

 

 

 

 

 

GND

1

26

-DB (0)

 

 

 

 

GND

2

27

-DB(1)

 

 

 

 

GND

3

28

-DB(2)

 

 

 

 

GND

4

29

-DB(3)

 

 

 

 

GND

5

30

-DB(4)

 

 

 

 

GND

6

31

-DB(5)

 

 

 

 

GND

7

32

-DB(6)

 

 

 

 

GND

8

33

-DB(7)

 

 

 

 

GND

9

34

-DB(P)

 

 

 

 

GND

10

35

GND

 

 

 

 

GND

11

36

GND

 

 

 

 

Reserved

12

37

Reserved

 

 

 

 

(Open)

13

38

TERMPWR

 

 

 

 

Reserved

14

39

Reserved

 

 

 

 

GND

15

40

GND

 

 

 

 

GND

16

41

-ATN

 

 

 

 

GND

17

42

GND

 

 

 

 

OND

18

43

-BSY

 

 

 

 

OND

19

44

-ACK

 

 

 

 

GND

20

45

-RST

GND

21

46

-MSG

 

 

 

 

GND

22

47

-SEL

 

 

 

 

GND

23

48

-C/D

 

 

 

 

GND

24

49

-REQ

 

 

 

 

GND

25

50

-I/O

 

 

 

 

Note: Reserved pins are connected to GND.

Figure 4-1Pin assignment

4-5

Image 33
Contents Version Page Table of Contents Diagnostics Group 3 error flowchart no paper in ADF paper tray Page General GeneralSystem Block Diagram Outer View Device ConfigurationComponents Functional Specifications Remarks Functional SpecificationsEnvironmental Specifications Remarks Environmental SpecificationsRemoving the Shipping Bracket OperationRemove the shipping retainer Fasten the shipping retainer Indication Panel Power On/OffNames and functions of the indicators Setting the Scsi ID and Connecting the Interface CableScsi ID setting Name Color FunctionScsi Cable Connection Position Paper Size Paper SpecificationsPaper conditions 2.1 ADFItems to avoid FIatbedADF readable area Readable areaDocument Setting Method When the document size is of letter/A4 size or smallerFlatbed When the document is a thick book Setting the ADF paper chute2 ADF Placing the document on the ADF paper chute Placing the documents on the ADF paper chuteSeparating the sheets for easy feeding Angling the document sheetsCleaning the document cover and the document glass CleaningCleaning inside the ADF Page Interface ∙ Busy ∙ Check Condition ∙ Good ∙ Reservation Conflict Connection Physical SpecificationsSpecifications Physical Specification1SCSI physical specifications TerminationPin assignments Signal Name Pin NumberSystem configuration System configurationScsi Bus Addresses of Scsi devices2Bus signals Bus signals3Bus phases vs. signal drive sources 1/2 Bus signal drive conditionsBus Phases Method of driving the interface signalOr connection Nonor connection 5Signal delay times definition Time Definition BUS Free phase Signal delay times definitionTime Definition Arbitration phase BSY Scsi SEL Selection phase Information Transfer phases Information Transfer phase type PhaseDB7 to 9,P Transfer Direction Asynchronous transfer from target to initiator Asynchronous information transferAsynchronous transler from initiator to target Commands Relative addressing is not supportedControl byte is not supported Commands Reserve Unit commandOperation Command Code hex Description Bit and field described as Reserved areReserve Unit command Command phase initiator Õ target TP third party ByteTpid third party device ID Byte Release Unit command Release Unit command Command phase initiator → targetTP third party Byte Inquiry command Command phase initiator → target Inquiry command10 Inquiry command Step Bus phase Initiator operation Target operationEvpd enable vital product data Byte Code ByteCAllocation length Byte Aenc Inquiry data Data in phase target → initiatorADF mode Byte 24, bit SftRst Soft Reset ByteColor mode Byte 24, bit 6 to ISO version, Ecma version, Ansi approved version ByteRequest Sense command Request Sense command Command phase initiator → target11 Request Sense command Error code Byte Sense data Data EN phase target → initiatorAllocation length Byte Valid ByteFM file mark Byte ILI incorrect length indicator ByteEOM end of medium Byte Sense key ByteCommand-specific information bytes Bytes 8 to B Send Diagnostic commandSense Additional Description Sense codeSend Diagnostic command Command phase initiator → target PF page format ByteSlftst selftest Byte Test Unit Ready command Contents of self-testResults of self-test Acknowledgment Test Unit Ready command Command phase initiator → targetSET Window command Command phase initiator → target SET Window commandWindow date Data OUT phase initiator → target Transfer Length Bytes 6 toHeader Window descriptor block Window identifier Byte Y resolution XR, YR Bytes 2 to 3 and 4 toAuto Byte Upper left X,YULX, ULY Bytes 6 to 9, a to DRemarks Brightness ByteRIF reverse image format Byte 1D, bit Bit per pixel Byte 1ABit ordering Bytes 1E to 1F Halftone pattern Bytes lB to 1C lB reserved7.4 B&W Scanning Vender unique parameters Update of ScanPartner 600C OEM manualCompression type, argument Bytes 20 to 18 Vender unique parameters byte 28 and laterPage 19 Vendor unique parameters byte 28 and later Color Scanning Vender unique parametersADF Byte 2A, Bit Source Byte 2A, BitShadow value Byte 2C Highlight value Byte 2BLine width Byte 2D to 2E Line count Byte 2F toObject Position command Object Position command Command phase initator → target Position type ByteBit Load object Unload objectCount Bytes 2 to NormalRead command Step Bus phase Initiator operation Target operationADF sequence Data type code Byte Read command Command phase initiator → targetData type qualifier Bytes 4 to Transfer length TL Bytes 6 toImage data Data Type Code = Data in phase target → initiatorFor binary data Pixel size data Data Type Code =Scan Command phase initiator → target Scan commandCode Status of unit Status Status phase target initiatorPhase ATN detection timing MessagesATN detection Command Complete X00 Message in phase target → initiator Message typesMessage Abort X06 Message OUT phase initiator → target Message Reject X07 Message IN/OUT phase initiator → targetATN detection phase Action BUS Device Reset X0C Message OUT phase initiator → target No Operation X08 Message OUT phase initiator → targetPhase when ATN is detected Action Message rejected ActionIdendify X80 to XFF Message OUT phase initiator → target Initial sequence Command SequenceRead sequence for B&W mode Read command sequenceRead sequence Single ReadMultiple Read Status Transition of Logical Unit Sense key Error TableItems for Specifying Window Page Online diagnostics Ready LED Paper Jam LED Error indicationOnline diagnostics Offline diagnostics results Offline diagnosticsDiagnostic flowcharts Group 1 error flowchart Lamp assemblyGroup 2 error flowchart Flatbed/ADF motor Group 3 error flowchart paper in ADF paper tray Group 3 error flowchart no paper in ADF paper tray