Fujitsu 600C manual Window identifier Byte, Auto Byte, Y resolution XR, YR Bytes 2 to 3 and 4 to

Page 64

(c)Window identifier: Byte 0

Specifies a unique value that identifies a window. The value may be 0 to 255. If two or more window identifiers are specified for a single set of window data, the most recently specified identifier is validated This scanner allows only one window to be set Therefore, only 0 may be specified in this field. II other than 0 is specified, this scanner returns the following error:

Status: B~0000l' (CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

(d)Auto: Byte 1

This scanner does not support auto. If a value other than 0 is specified, this scanner returns the foIl error:

Status: B'0000l' (CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

(e)X, Y resolution (XR, YR): Bytes 2 to 3 and 4 to 5

Specified here are the resolutions in the horizontal (X) and vertical (Y) scanning directions, in pixels per

inch. If 0 is specified, the default value (300 dpi) is assumed. The acceptable resolution value is as 60, 75, 80, 100, 120, 150, 200, 240, 300, 600. If a value is specified that does not comply with these conditions, this scanner returns the following error:

Status: B'0000l' (CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

(f)Upper left X,Y(ULX, ULY): Bytes 6 to 9, A to D

Specified here are the X and Y coordinates of the upper-left comer of the window. The coordinates expressed in units of 1/1200 inches relative to the upper-left comer of the maximum scan area. If the ULX or ULY value is outside the maximum scan area of this scanner, this scanner returns the following error:

Status: B'00001'(CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

(g)Width, length (W, L): Bytes E to 11, 12 to 15

Specifies here are the width and length of the window, in units of 1/1200 inches. If the W or L value outside the maximum scan area of this scanner; the following error is returned:

Status: B'0000l' (CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

The same error is also returned if this scanner is set to less than one raster line for vertical scanning less than two bytes for horizontal scanning.

Notes:

1.ULX, ULY, W, L versus maximum scan area: 0< (ULX + W) ó 10200 (in 1/1200 inches)

0< (ULY + L) ó 13937 (in 1/1200 inches) for flatbed scan 0< (ULY + L) ó- 16800 (in 1/1200 inches) for ADF scan

2.Conditions for horizontal scanning: 9< {XR x W/1200] ó 5100

4-36

Image 64
Contents Version Page Table of Contents Diagnostics Group 3 error flowchart no paper in ADF paper tray Page General GeneralSystem Block Diagram Device Configuration Outer ViewComponents Functional Specifications Functional Specifications RemarksEnvironmental Specifications Environmental Specifications RemarksOperation Removing the Shipping BracketRemove the shipping retainer Fasten the shipping retainer Power On/Off Indication PanelSetting the Scsi ID and Connecting the Interface Cable Names and functions of the indicatorsScsi ID setting Name Color FunctionScsi Cable Connection Position Paper Specifications Paper SizePaper conditions 2.1 ADFFIatbed Items to avoidReadable area ADF readable areaWhen the document size is of letter/A4 size or smaller Document Setting MethodFlatbed Setting the ADF paper chute When the document is a thick book2 ADF Placing the documents on the ADF paper chute Placing the document on the ADF paper chuteAngling the document sheets Separating the sheets for easy feedingCleaning Cleaning the document cover and the document glassCleaning inside the ADF Page Interface ∙ Busy ∙ Check Condition ∙ Good ∙ Reservation Conflict Physical Specifications ConnectionPhysical Specification Specifications1SCSI physical specifications TerminationSignal Name Pin Number Pin assignmentsSystem configuration System configurationScsi Bus Addresses of Scsi devicesBus signals 2Bus signalsBus signal drive conditions 3Bus phases vs. signal drive sources 1/2Method of driving the interface signal Bus PhasesOr connection Nonor connection 5Signal delay times definition Time Definition Signal delay times definition BUS Free phaseTime Definition Arbitration phase BSY Scsi SEL Selection phase Information Transfer phase type Phase Information Transfer phasesDB7 to 9,P Transfer Direction Asynchronous information transfer Asynchronous transfer from target to initiatorAsynchronous transler from initiator to target Relative addressing is not supported CommandsControl byte is not supported Reserve Unit command CommandsOperation Command Code hex Description Bit and field described as Reserved areTP third party Byte Reserve Unit command Command phase initiator Õ targetTpid third party device ID Byte Release Unit command Command phase initiator → target Release Unit commandTP third party Byte Inquiry command Inquiry command Command phase initiator → target10 Inquiry command Step Bus phase Initiator operation Target operationCode Byte Evpd enable vital product data ByteCAllocation length Byte Inquiry data Data in phase target → initiator AencSftRst Soft Reset Byte ADF mode Byte 24, bitColor mode Byte 24, bit 6 to ISO version, Ecma version, Ansi approved version ByteRequest Sense command Command phase initiator → target Request Sense command11 Request Sense command Sense data Data EN phase target → initiator Error code ByteAllocation length Byte Valid ByteILI incorrect length indicator Byte FM file mark ByteEOM end of medium Byte Sense key ByteSend Diagnostic command Command-specific information bytes Bytes 8 to BSense Additional Description Sense codePF page format Byte Send Diagnostic command Command phase initiator → targetSlftst selftest Byte Contents of self-test Test Unit Ready commandResults of self-test Test Unit Ready command Command phase initiator → target AcknowledgmentSET Window command SET Window command Command phase initiator → targetTransfer Length Bytes 6 to Window date Data OUT phase initiator → targetHeader Window descriptor block Y resolution XR, YR Bytes 2 to 3 and 4 to Window identifier ByteAuto Byte Upper left X,YULX, ULY Bytes 6 to 9, a to DBrightness Byte RemarksBit per pixel Byte 1A RIF reverse image format Byte 1D, bitBit ordering Bytes 1E to 1F Halftone pattern Bytes lB to 1C lB reservedUpdate of ScanPartner 600C OEM manual 7.4 B&W Scanning Vender unique parametersCompression type, argument Bytes 20 to 18 Vender unique parameters byte 28 and laterPage Color Scanning Vender unique parameters 19 Vendor unique parameters byte 28 and laterADF Byte 2A, Bit Source Byte 2A, BitHighlight value Byte 2B Shadow value Byte 2CLine width Byte 2D to 2E Line count Byte 2F toObject Position command Position type Byte Object Position command Command phase initator → targetBit Unload object Load objectCount Bytes 2 to NormalStep Bus phase Initiator operation Target operation Read commandADF sequence Read command Command phase initiator → target Data type code ByteData type qualifier Bytes 4 to Transfer length TL Bytes 6 toData in phase target → initiator Image data Data Type Code =For binary data Pixel size data Data Type Code =Scan command Scan Command phase initiator → targetStatus Status phase target initiator Code Status of unitMessages Phase ATN detection timingATN detection Message types Command Complete X00 Message in phase target → initiatorMessage Message Reject X07 Message IN/OUT phase initiator → target Abort X06 Message OUT phase initiator → targetATN detection phase Action No Operation X08 Message OUT phase initiator → target BUS Device Reset X0C Message OUT phase initiator → targetPhase when ATN is detected Action Message rejected ActionIdendify X80 to XFF Message OUT phase initiator → target Command Sequence Initial sequenceRead command sequence Read sequence for B&W modeRead sequence Single ReadMultiple Read Status Transition of Logical Unit Error Table Sense keyItems for Specifying Window Page Ready LED Paper Jam LED Error indication Online diagnosticsOnline diagnostics Offline diagnostics Offline diagnostics resultsGroup 1 error flowchart Lamp assembly Diagnostic flowchartsGroup 2 error flowchart Flatbed/ADF motor Group 3 error flowchart paper in ADF paper tray Group 3 error flowchart no paper in ADF paper tray