Fujitsu 600C manual Messages, Phase ATN detection timing

Page 79

Table 4.22

Code

Status of unit

 

 

00100

BUSY

 

A target or logical unit cannot accept a new command.

 

The logical unit is executing processing.

 

The target is executing processing on a specified logical unit or other logical unit.

 

The target intends to report to an other initiator the sense data of a specified logical unit.

 

The target intends to report to an other initiator the sense data of a logical unit that was not specified.

 

The target intends to report the status to any initiator.

 

 

01100

RESERVATION CONFLICT

 

The specified unit is already reserved by another initiator.

When a target is released from the BUSY status, it will not issue a notification of the release. Therefore initiator needs to check the status of units periodically and needs to issue the command again.

4.6 Messages

This section describes the detection of an ATN signal and explains the types of messages supported by this scanner.

4.6.1ATN detection

The following table summarizes the timing at which this scanner detects and ATN signal.

 

Table 4-23

 

 

Phase

ATN detection timing

 

 

SELECTION

Immediately before a phase change

 

 

COMMAND

Immediately before a phase change

 

 

DATA OUT

Immediately before a phase change

 

 

DATA IN

Immediately before a phase change

 

 

STATUS

Immediately before a phase change

 

 

MESSAGE OUT

Upon each reception of a message

 

 

MESSAGE IN

Upon each transmission of a message

 

 

4-51

Image 79
Contents Version Page Table of Contents Diagnostics Group 3 error flowchart no paper in ADF paper tray Page General GeneralSystem Block Diagram Outer View Device ConfigurationComponents Functional Specifications Remarks Functional SpecificationsEnvironmental Specifications Remarks Environmental SpecificationsRemoving the Shipping Bracket OperationRemove the shipping retainer Fasten the shipping retainer Indication Panel Power On/OffName Color Function Setting the Scsi ID and Connecting the Interface CableNames and functions of the indicators Scsi ID settingScsi Cable Connection Position 2.1 ADF Paper SpecificationsPaper Size Paper conditionsItems to avoid FIatbedADF readable area Readable areaWhen the document size is of letter/A4 size or smaller Document Setting MethodFlatbed Setting the ADF paper chute When the document is a thick book2 ADF Placing the document on the ADF paper chute Placing the documents on the ADF paper chuteSeparating the sheets for easy feeding Angling the document sheetsCleaning the document cover and the document glass CleaningCleaning inside the ADF Page Interface ∙ Busy ∙ Check Condition ∙ Good ∙ Reservation Conflict Connection Physical SpecificationsTermination Physical SpecificationSpecifications 1SCSI physical specificationsPin assignments Signal Name Pin NumberAddresses of Scsi devices System configurationSystem configuration Scsi Bus2Bus signals Bus signals3Bus phases vs. signal drive sources 1/2 Bus signal drive conditionsMethod of driving the interface signal Bus PhasesOr connection Nonor connection 5Signal delay times definition Time Definition Signal delay times definition BUS Free phaseTime Definition Arbitration phase BSY Scsi SEL Selection phase Information Transfer phase type Phase Information Transfer phasesDB7 to 9,P Transfer Direction Asynchronous transfer from target to initiator Asynchronous information transferAsynchronous transler from initiator to target Relative addressing is not supported CommandsControl byte is not supported Bit and field described as Reserved are Reserve Unit commandCommands Operation Command Code hex DescriptionTP third party Byte Reserve Unit command Command phase initiator Õ targetTpid third party device ID Byte Release Unit command Command phase initiator → target Release Unit commandTP third party Byte Step Bus phase Initiator operation Target operation Inquiry commandInquiry command Command phase initiator → target 10 Inquiry commandCode Byte Evpd enable vital product data ByteCAllocation length Byte Aenc Inquiry data Data in phase target → initiatorISO version, Ecma version, Ansi approved version Byte SftRst Soft Reset ByteADF mode Byte 24, bit Color mode Byte 24, bit 6 toRequest Sense command Command phase initiator → target Request Sense command11 Request Sense command Valid Byte Sense data Data EN phase target → initiatorError code Byte Allocation length ByteSense key Byte ILI incorrect length indicator ByteFM file mark Byte EOM end of medium ByteSense code Send Diagnostic commandCommand-specific information bytes Bytes 8 to B Sense Additional DescriptionPF page format Byte Send Diagnostic command Command phase initiator → targetSlftst selftest Byte Contents of self-test Test Unit Ready commandResults of self-test Acknowledgment Test Unit Ready command Command phase initiator → targetSET Window command Command phase initiator → target SET Window commandTransfer Length Bytes 6 to Window date Data OUT phase initiator → targetHeader Window descriptor block Upper left X,YULX, ULY Bytes 6 to 9, a to D Y resolution XR, YR Bytes 2 to 3 and 4 toWindow identifier Byte Auto ByteRemarks Brightness ByteHalftone pattern Bytes lB to 1C lB reserved Bit per pixel Byte 1ARIF reverse image format Byte 1D, bit Bit ordering Bytes 1E to 1F18 Vender unique parameters byte 28 and later Update of ScanPartner 600C OEM manual7.4 B&W Scanning Vender unique parameters Compression type, argument Bytes 20 toPage Source Byte 2A, Bit Color Scanning Vender unique parameters19 Vendor unique parameters byte 28 and later ADF Byte 2A, BitLine count Byte 2F to Highlight value Byte 2BShadow value Byte 2C Line width Byte 2D to 2EObject Position command Position type Byte Object Position command Command phase initator → targetBit Normal Unload objectLoad object Count Bytes 2 toStep Bus phase Initiator operation Target operation Read commandADF sequence Transfer length TL Bytes 6 to Read command Command phase initiator → targetData type code Byte Data type qualifier Bytes 4 toPixel size data Data Type Code = Data in phase target → initiatorImage data Data Type Code = For binary dataScan Command phase initiator → target Scan commandCode Status of unit Status Status phase target initiatorMessages Phase ATN detection timingATN detection Message types Command Complete X00 Message in phase target → initiatorMessage Message Reject X07 Message IN/OUT phase initiator → target Abort X06 Message OUT phase initiator → targetATN detection phase Action Message rejected Action No Operation X08 Message OUT phase initiator → targetBUS Device Reset X0C Message OUT phase initiator → target Phase when ATN is detected ActionIdendify X80 to XFF Message OUT phase initiator → target Initial sequence Command SequenceSingle Read Read command sequenceRead sequence for B&W mode Read sequenceMultiple Read Status Transition of Logical Unit Sense key Error TableItems for Specifying Window Page Ready LED Paper Jam LED Error indication Online diagnosticsOnline diagnostics Offline diagnostics results Offline diagnosticsGroup 1 error flowchart Lamp assembly Diagnostic flowchartsGroup 2 error flowchart Flatbed/ADF motor Group 3 error flowchart paper in ADF paper tray Group 3 error flowchart no paper in ADF paper tray