Operating Instructions and Parts ManualHVLP Gravity Feed Spray Gun
Troubleshooting Chart (Cont.)
|
| Symptom | Possible Cause(s) | Corrective Action | |||
|
| Fluid leaking from fluid tip | 1. | Packing nut too tight | 1. | Adjust | |
|
| of pressure feed spray gun | 2. | Fluid tip worn or damaged | 2. | Replace tip and/or needle | |
|
|
| 3. | Foreign matter on tip | 3. | Clean | |
|
|
| 4. | Fluid needle spring broken | 4. | Replace | |
|
| Excessive overspray | 1. | Too high atomization pressure | 1. | Reduce pressure | |
|
|
| 2. | Too far from work surface | 2. | Adjust to proper distance | |
|
|
| 3. | Improper stroking (arcing, gun | 3. | Move at moderate pace, parallel to surface | |
|
|
|
| motion too fast) |
|
|
|
|
| Will not spray | 1. | No pressure at gun | 1. | Check air lines | |
|
|
| 2. | Fluid control not open enough | 2. | Open fluid control | |
|
|
| 3. | Thin fluid or change to pressure feed system | |||
|
|
| 3. | Fluid too heavy | |||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
For Replacement Parts, call 1-800-543-6400
Please provide following information: | Address parts correspondence to: | |
- Model number | Campbell Hausfeld | |
- | Attn: Parts Department | |
- | Part description and number as shown in parts list | 100 Production Drive |
|
| Harrison, OH 45030 U.S.A. |
Manual de Instrucciones y Lista de PiezasPistola Pulverizadora HVLP Alimentada por Gravedad
Guía de Diagnóstico de Averías
| Problema | Posible(s) Causa(s) | Acción a Tomar | ||||||||
|
|
|
| Acumulación de | 1. | Los orificios a los lados de la tapa de | 1. | Límpielos. Use únicamente una punta no metálica. | |||
|
|
|
| ||||||||
|
|
|
| pintura a la |
| aire están tapados |
|
| |||
|
|
|
| derecha o izquier- | 2. | Acumulación de impurezas a los lados | 2. | Límpiela | |||
|
|
|
| da |
| de la boquilla |
|
| |||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Acumulación de | 1. | Acumulación de material reseco en la | 1. | Límpiela | |
|
|
|
|
| |||||||
|
|
|
|
|
| pintura en la parte |
| parte superior o inferior de la boquilla |
|
| |
|
|
|
|
|
| superior o inferior | 2. | La tapa de aire está floja o el asiento | 2. | Límpiela y apriétela | |
|
|
|
|
|
|
|
|
| está sucio |
|
|
|
|
|
|
|
|
|
| 3. | La tapa de aire está obstruída | 3. | Límpiela. Use únicamente una punta no metálica. |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Acabado | 1. | El control del patrón está muy abierto | 1. | Cierre parcialmente el control de fluído | |
|
|
|
|
|
| ||||||
|
|
|
|
|
| disparejo | 2. | El control de fluído está muy bajo | 2. | Aumente el nivel de fluído | |
|
|
|
|
|
|
|
| 3. | Está atomizando demasiado aire | 3. | Reduzca la presión de atomización |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Acumulación de | 1. | El control de rocío está cerrado parcial- | 1. | Ábralo un poco | |
|
|
|
|
|
| pintura en el cen- |
| mente |
|
| |
|
|
|
|
|
| tro | 2. | El material está muy espeso | 2. | Diluya el material hasta alcanzar la viscosidad adecuada | |
|
|
|
|
|
|
|
| 3. | La presión de atomización es muy baja | 3. | Aumente la presión de atomización |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Rocío salpicado | 1. | El nivel de material es muy bajo | 1. | Añádale más material |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
| 2. | El envase está muy inclinado | 2. | Colóquelo más derecho |
|
|
|
|
|
|
|
| 3. | La conexión del suministro de fluído | 3. | Apriétela |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| está floja |
|
|
|
|
|
|
|
|
|
| 4. | La boquilla o el asiento están flojos o | 4. | Ajústela o reemplácela |
|
|
|
|
|
|
|
|
| dañados |
|
|
|
|
|
|
|
|
|
|
|
|
|
9
| 7 |
| 27 |
|
| 8 |
|
| |
|
|
| 12 | |
|
|
|
| |
|
|
| 23 | 10 |
|
|
|
| |
|
|
|
| 13 |
|
|
|
| 14 |
3 | 5 |
|
|
|
|
|
|
| |
|
|
|
| 11 |
|
|
|
| 17 |
|
|
|
| 14 |
| 4 | 6 |
| 18 |
|
|
|
| 19 |
15
16
32
| 5. | La tuerca que sostiene el empaque de | 5. | Lubríquela o apriétela |
|
| la aguja está floja o dañada |
|
|
| 6. | El orificio de ventilación está obstruído | 6. | Destápelo |
Fuga de fluído a través de | 1. | La tuerca que sostiene el empaque está | 1. | Apriétela, pero sin restringir la aguja |
la tuerca de empaque de la |
| floja |
|
|
aguja | 2. | El empaque está desgastado o seco | 2. | Reemplácela o lubríquela (con aceite sin silicón) |
|
|
|
|
|
El aire se fuga a través de la | 1. | El vástago de la válvula se atasca | 1. | Lubríquelo |
tapa de aire aún sin apretar | 2. | La válvula de aire o el asiento están conta- | 2. | Límpielos |
el gatillo |
| minados |
|
|
| 3. | La válvula de aire o el asiento están des- | 3. | Reemplácela |
|
| gastados o dañados |
|
|
| 4. | El resorte de la válvula de aire está roto | 4. | Reemplácela |
| 5. | El vástago de la válvula está torcido | 5. | Reemplácela |
El fluído se fuga a través de | 1. | La tuerca que sostiene el empaque está | 1. | Ajústela |
la boquilla de la pistola pul- |
| muy apretada |
|
|
verizadora a presión | 2. | La boquilla está desgastada o dañada | 2. | Reemplace la boquilla y aguja con un juego de boquilla/aguja |
| 3. | La boquilla está sucia |
| ondeados |
| 3. | Límpiela |
|
|
| 20 |
| 26 | 22 | 21 |
2 |
| ||
|
| ||
|
|
|
125
24
28
33
31
29 30
HVLP Test Cap Kit Kit de test de capuchon HVLP Juego de tapa de prueba HVLP
| 4. | El resorte de la aguja está roto | 4. | Reemplácela |
Rocío excesivo | 1. | La presión de atomización es muy alta | 1. | Reduzca la presión |
| 2. | La pistola está muy lejos de la superfi- | 2. | Acérquela a la superficie |
|
| cie |
|
|
3.Está pintando incorrectamente (está 3. El movimiento debe ser moderado y paralelo a la superficie moviendo la pistola muy rápido)
No puede rociar | 1. | La pistola no tiene presión | 1. | Chequée las líneas de aire |
| 2. | El control de fluído está muy cerrado | 2. | Abra el control de fluído |
| 3. | El fluído está muy espeso | 3. | Diluya el fluído o use el sistema a presión |