Environmental requirements
To ensure proper operation, the switch must not be subjected to environmental conditions beyond those for which it was tested. The ranges specified in Table 16 list the acceptable environment for both operating and
Table 15 Environmental requirements
Condition | Acceptable range during operation | Acceptable range during |
|
|
|
Ambient temperature | 104°F/40 °C at sea level, derated | |
| 1 C per 1000 ft above sea level | of change of 20 C /hr |
|
|
|
Humidity | 5% to 90% relative humidity, | 50% to 80% relative humidity, |
| ||
|
|
|
Altitude | 0 to 10,000 ft (3 km) above sea | 0 to 40,000 ft (12 km) above sea |
| level | level |
|
|
|
Shock | 40 G, 2mS duration | 140 G, 2mS duration |
|
|
|
Vibration | 0.5 G, 10 to 500 Hz | 2.0 G, 5 to 500 Hz |
|
|
|
Airflow | 47 cubic ft per minute | None required |
|
|
|
Supported SFPs
Do not use unsupported SFPs; they can affect switch operability. They may not fit correctlyand may void your warranty. See Optional hardware kits for a list of supported SFPs.
For a complete list of supported devices, refer to the latest version of the HP StorageWorks SAN design reference guide:
http://h18000.www1.hp.com/products/storageworks/san/documentation.html
Supported HBAs
For a list of HBAs that have been tested and are known to work with the SAN switches, refer to the latest version of the HP StorageWorks SAN design reference guide:
http://h18000.www1.hp.com/products/storageworks/san/documentation.htm