102
You can also view POST error codes with the show diagnostic post command. This command displays the results of each POST that executed at
Example
SFS-270# show diagnostic post
================================================================================
Post Status
================================================================================
card(1) | failed | 1:0:0:0 |
fan(1) | passed | 0:0:0:0 |
fan(2) | passed | 0:0:0:0 |
0:0:0:0 |
To view FRU errors on your Topspin 270/Cisco SFS 7008, enter the show diagnostic
Example
SFS-270# show diagnostic fru-error
================================================================================
================================================================================
card(1) _FRU_POWER_CONTROLLER_CONFIG_ERR
fan(1)none
fan(2)none
The following types of hardware errors are logged for the Topspin 270/Cisco SFS 7008 power supply:
Table
Error Number | Description |
1 | Power Supply DC Fail Error |
|
|
2 | Power Supply Fan Fail Error |
|
|
3 | Power Supply I2C Communication Error |
|
|