Cisco Systems 7008, 270 manual Electrical Specifications, EMC/Immunity, Safety, Acoustics

Page 104

106

Table 7-1:Chassis and Management General Specifications

Operating Temperature Ranges

0 to 40C

Non-Operating Vibration, random

2.09Grms, 3-axis, bottom/top, left/right,

 

 

front/back

 

 

 

Max. Operating Inclination

15 degrees

 

 

 

Electrical Specifications

 

Table 7-2:Electrical Specifications

 

 

 

 

Category

Specification

 

AC Input

Auto-ranging 90-264VAC, 47-63Hz.

 

 

 

Maximum Power

<600 Watts

 

consumption

 

 

EMC/Immunity

Table 7-3:EMC/Immunity

Description

FCC; CFR 47 Part 15, Subpart B Class A

ICES-003 Issue 2

EN 61000-3-2 (Harmonics), EN 61000-3-3 (Flicker),

EN 55022: 1998, EN 55024:1998;

EN 61000-4-1,2,3,4,5,6,8,11

Japan: VCCI-V3/02.04

Safety

Table 7-4: Safety

Description

UL60950, 3rd ed.

CSA 22.2 No. 60950:2000

IEC60950, EN60950, EN60825-1 and EN60825-2

Acoustics

Table 7-5: Acoustics

Country

Description

Deployment

 

Sound Pressure

37dB at 25C ambient ISO 7779 and section 8.5 of ISO

 

3744:1994(E)

 

 

Sound Power

50dB at 25C ambient ISO 7779, section 8.6 of ISO

 

3744:1994(E)

Image 104
Contents Topspin 270/Cisco SFS 7008 Hardware Guide Release Page Regulatory Notices Vii Managing Individual Components Monitoring the Topspin 270/Cisco SFS 109 FCC Statement Safety Information Electrical CautionsViii Contact Information General CautionsPage System Architecture Hot StandbyInfiniBand Connectivity FlexibilityHi-Availability HardwareDiagram of the Chassis About the Topspin 270/Cisco SFS 7008 ChassisNon-Blocking Architecture Fabric2Back Chassis View Chassis Slot Numbering 3Chassis Slot Numbering in Front Non-port SideDimensions Power SuppliesConnections LEDsFan Trays Management Interface ModulesFabric Controller Modules Node and Core SlotsMaster/Slave and Standby Roles Node SlotRack Alarm Line Interface Modules LIMChassis ID Module How the Chassis ID is UsedAdministrative Features Prepare the Site Read the Cautionary StatementsRequirements Rack Mount InstallationMount the Topspin 270/Cisco SFS 7008 Chassis in a Rack 1Install Appropriate Rack in Shelf 2Unscrew Extra Rack Ears from the Chassis 4Rack Ears Flush with Rails Attach a Serial Console Cable to a PC or Terminal Install Optional HA ComponentsConnect Management Devices Baud 9600 bps Recommended Management ConfigurationConnect an Ethernet Cable to the Ethernet Management Port Power on the Chassis 8Power Jack LocationsConfigure Basic Connectivity Enter the interface mgmt-ethernet commandSFS-270config#interface mgmt-ethernet SFS-270#copy running-config startup-configAssigning an Address Dynamically About ConnectorsConnect Network Devices Connecting InfiniBand Devices Manage the SystemLaunch Chassis Manager Optional Launch the Chassis ManagerPrepare Your Device 10Web Browser Window Optional Install the Element Manager GUI About the Field Replaceable Units Power Supply ModulesAbout the Power Supply Modules Locating the Power Supply Module Removing a Power Supply ModuleAbout a Failed Power Supply Power Cord back Power Supply front Installing a New Power Supply Module 3Pulling the Power Supply Module from the BayFan Tray Modules About the Fan Tray ModulesRemoving a Fan Module About a Failed Fan Tray5Loosening Captive Screws Installing a Fan Module 7Pushing Fan Module into SlotRemoving a Fabric Controller Fabric ControllersAbout the Fabric Controllers 9Loosen Captive Screws Before Removing Installing a Fabric Controller Upgrading the Controller CardRemoving a LIM Card Line Interface Management Modules LIMAbout LIM Cards 12Removing a Pinch-Type Connector 14Loosen the Captive Screws Installing a LIM Module 17Closing the LIM Module LeversManagement Interface Modules About Management Interface ModulesRemoving a Management Interface Module About a Failed Management Interface ModuleInstalling a Management Interface Module Chassis ID ModulesAbout Chassis ID Modules Removing a Chassis ID Module20Loosen the Captive Screws Installing a Replacement Chassis ID Module Upgrade all Cards in a Chassis Upgrading a Topspin 270/Cisco SFS 7008 with the CLIFile Type = Image Select Maintenance File ManagementUpgrading a Topspin 270/Cisco SFS 7008 with Element Manager Select Maintenance Boot Config 2Watching the File Copy ProgressUpgrading an Individual Controller Card Select View Device Front ViewUpgrading a Controller Card with the CLI Show the standby Controller card Upgrading Individual Node Cards Upgrading a Node Card with the CLI5Copy the .img File to Server Switch Upgrading a Node Card with Element Manager6Watching the File Copy Progress 8Disable and Enable the Node Cards Upgrading Node Cards with the Chassis Manager Upgrade a New Fabric Controller Module with the CLIUpgrading a New Fabric Controller Module SFS-270#reload no-failover SFS-270#install imageOS-image-230.imgPrimary-boot-image keyword Upgrade a New Fabric Controller Module with Element Manager Page Monitoring the Topspin 270/Cisco SFS 7008 System Interpreting the Front Panel LEDsInterpreting the System Status LED System-Wide Status LEDLocating the System-Wide Status LED Power Supply LEDs Locating the Power Supply LEDsConfig mode diag power-supply Test ledInterpreting the Power Supply LEDs 3Power Supply Identify LEDConfig mode -power-supply Config mode -diag fanFan LEDs LocationModule Active System Master Indicator Status Active Master Status IndicatorFabric Controller LEDs Interpreting the Fabric Controller LEDsInterpreting the Back Panel LEDs Management Interface Module LEDsManagement Interface Status LEDs Interpreting the Management Interface LEDsSystem Status LEDs Power Supply Module Status LEDs Fan Tray Module Status LEDsMaster Management Connection Status LED Ethernet Management Port RJ-45 connector LEDsChassis ID LEDs Interpreting the LIM Status LEDs LIM Status LEDsInfiniBand Port LEDs Interpreting the InfiniBand Port LEDs Monitoring the System with Chassis ManagerMonitor the Device Device Rear View and the Device Front View appear Page Monitor the Cards 12Chassis Manager Cards WindowMonitor the InfiniBand Ports 13Chassis Manager Ports WindowMonitor the Power Supplies 14Chassis Manager Port Properties Dialog Box15Chassis Manager Power Supplies Window Monitor the FansMonitor the Temperature 17Chassis Manager Sensors WindowMonitoring the System with Element Manager Interpreting the Summary TabInterpreting the Sensors Tab Interpreting the Power Supplies TabInterpreting the Fans Tab Monitor the Power Supplies Show power-supplyMonitor the System With the CLI Monitor the FansSFS-270#show sensor Monitor the SensorsShow sensor Page Self Tests About Diagnostic TestsLED Tests Run a Card Self-Test SFS-270#show diagnostic cardRun Card Tests SFS-270config-diag-card-11# exit SFS-270config# exit Run Chassis Tests More sysloghwiflogSFS-270#show diag chassis SFS-270config#diag chassis test standardRun a Chassis Standard Test TS270-1#show diag post Run Fan TestsRun a Self-Test on a Fan Enter the diag fan id command Run Power Supply Tests Run a LED Test on the Power SupplyRun a Self-Test on a Power Supply SFS-270#show power-supplySFS-270config#diag power-supply SFS-270#show diag power-supplyRun a Rack Locator Test 100SFS-270show diag rack-locator Displaying Hardware ErrorsEnable SFS-270#show diagnostic post SFS-270#show diagnostic fru-errorSpecifications and Compliance Certifications Chassis and Management InterfaceElectrical Specifications SafetyEMC/Immunity AcousticsProduct Markings 108 Index

270, 7008 specifications

Cisco Systems 7008,270 is a powerful model in the Cisco portfolio, showcasing cutting-edge technology aimed at meeting the demands of modern networking environments. Ideal for both enterprise and service provider applications, the 7008,270 offers exceptional flexibility, scalability, and performance.

One of the standout features of this device is its high-density interface options. The 7008,270 supports a mix of Ethernet speeds, including 1G, 10G, and 25G, enabling organizations to optimize their network infrastructure based on specific needs. This versatility provides businesses with seamless transition capabilities as they scale their operations, ensuring that they are always equipped with the right bandwidth.

In terms of performance, the Cisco 7008,270 boasts advanced processing power, allowing for swift data packet handling and reduced latency. The implementation of Enhanced IP Multicast is another key feature, which allows for efficient data delivery to multiple endpoints simultaneously. This is particularly beneficial for organizations that rely heavily on video conferencing and streaming services, as it enhances the overall quality of experience for end-users.

Additionally, the 7008,270 integrates Cisco's advanced security protocols. With features such as TrustSec and the ability to implement micro-segmentation, organizations can ensure that their data remains secure across the network. Cisco's Software-Defined Access (SD-Access) technology further simplifies network management by allowing for automated policy enforcement and enhanced visibility into network traffic.

Another notable characteristic is the seamless integration with existing Cisco platforms and software solutions. The 7008,270 works effectively with Cisco DNA (Digital Network Architecture), allowing businesses to leverage AI-driven analytics and insights to manage performance and security in real-time.

Energy efficiency is also a consideration with the 7008,270. The design includes energy-saving features, which not only reduce operational costs but also support sustainability initiatives within organizations. With an eye towards future-proofing, Cisco Systems has equipped the 7008,270 with options for software upgrades, enabling businesses to continuously enhance their capabilities without needing to replace hardware.

In conclusion, Cisco Systems 7008,270 stands out as a robust networking solution designed for scalability, security, and performance in diverse environments. Its flexibility in interface options, advanced processing power, and strong integration capabilities make it an excellent choice for organizations looking to fortify their network infrastructure and prepare for future demands.