Understanding the Core Slot to Mgmt Interface Module Connection

Each Core slot in the chassis (refer to “The Core Slot” on page 18) is connected to 1 port on the Management Interface module. The controller (fabric interface module inserted in the core slot) selects the Management Interface module to which it will connect.

The pairing of Management Interface module to core slot is as follows:

The Management Interface module in slot #15 is connected to the Fabric Controller Module in the Core slot #11.

The Management Interface module in slot #16 is connected to the Fabric Controller Module in the Core slot #12.

For example, removing the Fabric Controller from the Core slot 11 would cause both the Fabric

Controller card and its paired Management Interface module in slot 15 to fail-over. The new primary

Controller would be slot 12 and the primary Management Interface would be slot 16.

Fabric Controller Modules

See Figure 1-2 on page 14 for a diagram of the chassis.

Refer to “Installing a Fabric Controller” on page 44 for Fabric Controller module installation instructions.

The Topspin 270/Cisco SFS 7008 contains six fabric control modules.

The fabric controller modules perform the following roles within the system:

System Controller

Switch fabric spine

Switch fabric end-nodes

Stores redundant Vital Product Data (VPD) from the Chassis ID module. This allows the chassis to continue functioning (and the VPD information to be recovered) even if a Chassis ID module fails.

Each Fabric Controller module runs the management software and contains non-volatile storage.

The behavior and responsibility of each fabric controller module is determined by the type of slot into which it is inserted. Each fabric controller module can be installed in either a Node slot or a Core slot (refer to “Node and Core Slots” on page 18).

Master/Slave and Standby Roles

When the CPU of a fabric module detects that is in a Core slot, it will arbitrate for system mastership and run system wide control functions in addition to its local management functions.

One fabric controller in the Core slot acts as the Master

One fabric controller in the Core slot acts as the Standby to the Master

Fabric controllers in Node slots act as slaves

Note: Fabric controllers in Node slots do not act in active/standby configuration

Node and Core Slots

The fabric controller modules can occupy either a Node slot or a Core slot in the chassis.

The Node Slot

There are four Node slots in the Topspin 270/Cisco SFS 7008.

Fabric modules installed in Node slots provide fabric leaf switching, as opposed to controller functionality.

The Core Slot

There are two Core slots in the Topspin 270/Cisco SFS 7008.

Image 18
Contents Topspin 270/Cisco SFS 7008 Hardware Guide Release Page Regulatory Notices Vii Managing Individual Components Monitoring the Topspin 270/Cisco SFS 109 FCC Statement Safety Information Electrical CautionsViii Contact Information General CautionsPage System Architecture Hot StandbyHi-Availability InfiniBand ConnectivityFlexibility HardwareNon-Blocking Architecture Diagram of the ChassisAbout the Topspin 270/Cisco SFS 7008 Chassis Fabric2Back Chassis View Chassis Slot Numbering 3Chassis Slot Numbering in Front Non-port SideConnections DimensionsPower Supplies LEDsFan Trays Management Interface ModulesMaster/Slave and Standby Roles Fabric Controller ModulesNode and Core Slots Node SlotChassis ID Module Rack AlarmLine Interface Modules LIM How the Chassis ID is UsedAdministrative Features Prepare the Site Read the Cautionary StatementsRack Mount Installation Mount the Topspin 270/Cisco SFS 7008 Chassis in a RackRequirements 1Install Appropriate Rack in Shelf 2Unscrew Extra Rack Ears from the Chassis 4Rack Ears Flush with Rails Install Optional HA Components Connect Management DevicesAttach a Serial Console Cable to a PC or Terminal Recommended Management Configuration Connect an Ethernet Cable to the Ethernet Management PortBaud 9600 bps Power on the Chassis 8Power Jack LocationsSFS-270config#interface mgmt-ethernet Configure Basic ConnectivityEnter the interface mgmt-ethernet command SFS-270#copy running-config startup-configAbout Connectors Connect Network DevicesAssigning an Address Dynamically Connecting InfiniBand Devices Manage the SystemOptional Launch the Chassis Manager Prepare Your DeviceLaunch Chassis Manager 10Web Browser Window Optional Install the Element Manager GUI Power Supply Modules About the Power Supply ModulesAbout the Field Replaceable Units Removing a Power Supply Module About a Failed Power SupplyLocating the Power Supply Module Power Cord back Power Supply front Installing a New Power Supply Module 3Pulling the Power Supply Module from the BayRemoving a Fan Module Fan Tray ModulesAbout the Fan Tray Modules About a Failed Fan Tray5Loosening Captive Screws Installing a Fan Module 7Pushing Fan Module into SlotFabric Controllers About the Fabric ControllersRemoving a Fabric Controller 9Loosen Captive Screws Before Removing Installing a Fabric Controller Upgrading the Controller CardLine Interface Management Modules LIM About LIM CardsRemoving a LIM Card 12Removing a Pinch-Type Connector 14Loosen the Captive Screws Installing a LIM Module 17Closing the LIM Module LeversRemoving a Management Interface Module Management Interface ModulesAbout Management Interface Modules About a Failed Management Interface ModuleAbout Chassis ID Modules Installing a Management Interface ModuleChassis ID Modules Removing a Chassis ID Module20Loosen the Captive Screws Installing a Replacement Chassis ID Module Upgrade all Cards in a Chassis Upgrading a Topspin 270/Cisco SFS 7008 with the CLISelect Maintenance File Management Upgrading a Topspin 270/Cisco SFS 7008 with Element ManagerFile Type = Image Select Maintenance Boot Config 2Watching the File Copy ProgressUpgrading an Individual Controller Card Select View Device Front ViewUpgrading a Controller Card with the CLI Show the standby Controller card Upgrading Individual Node Cards Upgrading a Node Card with the CLI5Copy the .img File to Server Switch Upgrading a Node Card with Element Manager6Watching the File Copy Progress 8Disable and Enable the Node Cards Upgrade a New Fabric Controller Module with the CLI Upgrading a New Fabric Controller ModuleUpgrading Node Cards with the Chassis Manager SFS-270#install imageOS-image-230.img Primary-boot-image keywordSFS-270#reload no-failover Upgrade a New Fabric Controller Module with Element Manager Page Monitoring the Topspin 270/Cisco SFS 7008 System Interpreting the Front Panel LEDsSystem-Wide Status LED Locating the System-Wide Status LEDInterpreting the System Status LED Config mode diag power-supply Power Supply LEDsLocating the Power Supply LEDs Test ledInterpreting the Power Supply LEDs 3Power Supply Identify LEDFan LEDs Config mode -power-supplyConfig mode -diag fan LocationFabric Controller LEDs Module Active System Master Indicator StatusActive Master Status Indicator Interpreting the Fabric Controller LEDsInterpreting the Back Panel LEDs Management Interface Module LEDsInterpreting the Management Interface LEDs System Status LEDsManagement Interface Status LEDs Power Supply Module Status LEDs Fan Tray Module Status LEDsEthernet Management Port RJ-45 connector LEDs Chassis ID LEDsMaster Management Connection Status LED LIM Status LEDs InfiniBand Port LEDsInterpreting the LIM Status LEDs Monitoring the System with Chassis Manager Monitor the DeviceInterpreting the InfiniBand Port LEDs Device Rear View and the Device Front View appear Page Monitor the Cards 12Chassis Manager Cards WindowMonitor the InfiniBand Ports 13Chassis Manager Ports WindowMonitor the Power Supplies 14Chassis Manager Port Properties Dialog Box15Chassis Manager Power Supplies Window Monitor the FansMonitor the Temperature 17Chassis Manager Sensors WindowMonitoring the System with Element Manager Interpreting the Summary TabInterpreting the Power Supplies Tab Interpreting the Fans TabInterpreting the Sensors Tab Monitor the System With the CLI Monitor the Power SuppliesShow power-supply Monitor the FansMonitor the Sensors Show sensorSFS-270#show sensor Page About Diagnostic Tests LED TestsSelf Tests SFS-270#show diagnostic card Run Card TestsRun a Card Self-Test SFS-270config-diag-card-11# exit SFS-270config# exit Run Chassis Tests More sysloghwiflogSFS-270config#diag chassis test standard Run a Chassis Standard TestSFS-270#show diag chassis Run Fan Tests Run a Self-Test on a FanTS270-1#show diag post Enter the diag fan id command Run Power Supply Tests Run a LED Test on the Power SupplySFS-270config#diag power-supply Run a Self-Test on a Power SupplySFS-270#show power-supply SFS-270#show diag power-supplyRun a Rack Locator Test 100Displaying Hardware Errors EnableSFS-270show diag rack-locator SFS-270#show diagnostic post SFS-270#show diagnostic fru-errorSpecifications and Compliance Certifications Chassis and Management InterfaceEMC/Immunity Electrical SpecificationsSafety AcousticsProduct Markings 108 Index

270, 7008 specifications

Cisco Systems 7008,270 is a powerful model in the Cisco portfolio, showcasing cutting-edge technology aimed at meeting the demands of modern networking environments. Ideal for both enterprise and service provider applications, the 7008,270 offers exceptional flexibility, scalability, and performance.

One of the standout features of this device is its high-density interface options. The 7008,270 supports a mix of Ethernet speeds, including 1G, 10G, and 25G, enabling organizations to optimize their network infrastructure based on specific needs. This versatility provides businesses with seamless transition capabilities as they scale their operations, ensuring that they are always equipped with the right bandwidth.

In terms of performance, the Cisco 7008,270 boasts advanced processing power, allowing for swift data packet handling and reduced latency. The implementation of Enhanced IP Multicast is another key feature, which allows for efficient data delivery to multiple endpoints simultaneously. This is particularly beneficial for organizations that rely heavily on video conferencing and streaming services, as it enhances the overall quality of experience for end-users.

Additionally, the 7008,270 integrates Cisco's advanced security protocols. With features such as TrustSec and the ability to implement micro-segmentation, organizations can ensure that their data remains secure across the network. Cisco's Software-Defined Access (SD-Access) technology further simplifies network management by allowing for automated policy enforcement and enhanced visibility into network traffic.

Another notable characteristic is the seamless integration with existing Cisco platforms and software solutions. The 7008,270 works effectively with Cisco DNA (Digital Network Architecture), allowing businesses to leverage AI-driven analytics and insights to manage performance and security in real-time.

Energy efficiency is also a consideration with the 7008,270. The design includes energy-saving features, which not only reduce operational costs but also support sustainability initiatives within organizations. With an eye towards future-proofing, Cisco Systems has equipped the 7008,270 with options for software upgrades, enabling businesses to continuously enhance their capabilities without needing to replace hardware.

In conclusion, Cisco Systems 7008,270 stands out as a robust networking solution designed for scalability, security, and performance in diverse environments. Its flexibility in interface options, advanced processing power, and strong integration capabilities make it an excellent choice for organizations looking to fortify their network infrastructure and prepare for future demands.