Cisco Systems 7008, 270 manual Installing a Replacement Chassis ID Module

Page 52

52

Installing a Replacement Chassis ID Module

1.Remove the new Chassis ID module from the package.

2.Ground yourself appropriately.

3.Remove the old Chassis ID module, if you have not already done so. Refer to “Removing a Chassis ID Module” on page 50 if a Chassis ID module is still in place.

4.Align the chassis ID module with the slot and push the module completely into the bay.

5.Use the LEDs to verify the status of the module. Refer to “Chassis ID LEDs” on page 76.

The new Chassis ID has been previously serialized with the information that is unique to your chassis.

6.Reboot the chassis by using the GUI, or by using the reload command.

Example

SFS-270# reload

System configuration has been modified. Save? [yes (default)/no/*.cfg] yes

Proceed with reload? [confirm] SFS-270#

Connection to host lost.

#

Image 52
Contents Topspin 270/Cisco SFS 7008 Hardware Guide Release Page Regulatory Notices Vii Managing Individual Components Monitoring the Topspin 270/Cisco SFS 109 FCC Statement Safety Information Electrical CautionsViii Contact Information General CautionsPage System Architecture Hot StandbyInfiniBand Connectivity FlexibilityHi-Availability HardwareDiagram of the Chassis About the Topspin 270/Cisco SFS 7008 ChassisNon-Blocking Architecture Fabric2Back Chassis View Chassis Slot Numbering 3Chassis Slot Numbering in Front Non-port SideDimensions Power SuppliesConnections LEDsFan Trays Management Interface ModulesFabric Controller Modules Node and Core SlotsMaster/Slave and Standby Roles Node SlotRack Alarm Line Interface Modules LIMChassis ID Module How the Chassis ID is UsedAdministrative Features Prepare the Site Read the Cautionary StatementsMount the Topspin 270/Cisco SFS 7008 Chassis in a Rack Rack Mount InstallationRequirements 1Install Appropriate Rack in Shelf 2Unscrew Extra Rack Ears from the Chassis 4Rack Ears Flush with Rails Connect Management Devices Install Optional HA ComponentsAttach a Serial Console Cable to a PC or Terminal Connect an Ethernet Cable to the Ethernet Management Port Recommended Management ConfigurationBaud 9600 bps Power on the Chassis 8Power Jack LocationsConfigure Basic Connectivity Enter the interface mgmt-ethernet commandSFS-270config#interface mgmt-ethernet SFS-270#copy running-config startup-configConnect Network Devices About ConnectorsAssigning an Address Dynamically Connecting InfiniBand Devices Manage the SystemPrepare Your Device Optional Launch the Chassis ManagerLaunch Chassis Manager 10Web Browser Window Optional Install the Element Manager GUI About the Power Supply Modules Power Supply ModulesAbout the Field Replaceable Units About a Failed Power Supply Removing a Power Supply ModuleLocating the Power Supply Module Power Cord back Power Supply front Installing a New Power Supply Module 3Pulling the Power Supply Module from the BayFan Tray Modules About the Fan Tray ModulesRemoving a Fan Module About a Failed Fan Tray5Loosening Captive Screws Installing a Fan Module 7Pushing Fan Module into SlotAbout the Fabric Controllers Fabric ControllersRemoving a Fabric Controller 9Loosen Captive Screws Before Removing Installing a Fabric Controller Upgrading the Controller CardAbout LIM Cards Line Interface Management Modules LIMRemoving a LIM Card 12Removing a Pinch-Type Connector 14Loosen the Captive Screws Installing a LIM Module 17Closing the LIM Module LeversManagement Interface Modules About Management Interface ModulesRemoving a Management Interface Module About a Failed Management Interface ModuleInstalling a Management Interface Module Chassis ID ModulesAbout Chassis ID Modules Removing a Chassis ID Module20Loosen the Captive Screws Installing a Replacement Chassis ID Module Upgrade all Cards in a Chassis Upgrading a Topspin 270/Cisco SFS 7008 with the CLIUpgrading a Topspin 270/Cisco SFS 7008 with Element Manager Select Maintenance File ManagementFile Type = Image Select Maintenance Boot Config 2Watching the File Copy ProgressUpgrading an Individual Controller Card Select View Device Front ViewUpgrading a Controller Card with the CLI Show the standby Controller card Upgrading Individual Node Cards Upgrading a Node Card with the CLI5Copy the .img File to Server Switch Upgrading a Node Card with Element Manager6Watching the File Copy Progress 8Disable and Enable the Node Cards Upgrading a New Fabric Controller Module Upgrade a New Fabric Controller Module with the CLIUpgrading Node Cards with the Chassis Manager Primary-boot-image keyword SFS-270#install imageOS-image-230.imgSFS-270#reload no-failover Upgrade a New Fabric Controller Module with Element Manager Page Monitoring the Topspin 270/Cisco SFS 7008 System Interpreting the Front Panel LEDsLocating the System-Wide Status LED System-Wide Status LEDInterpreting the System Status LED Power Supply LEDs Locating the Power Supply LEDsConfig mode diag power-supply Test ledInterpreting the Power Supply LEDs 3Power Supply Identify LEDConfig mode -power-supply Config mode -diag fanFan LEDs LocationModule Active System Master Indicator Status Active Master Status IndicatorFabric Controller LEDs Interpreting the Fabric Controller LEDsInterpreting the Back Panel LEDs Management Interface Module LEDsSystem Status LEDs Interpreting the Management Interface LEDsManagement Interface Status LEDs Power Supply Module Status LEDs Fan Tray Module Status LEDsChassis ID LEDs Ethernet Management Port RJ-45 connector LEDsMaster Management Connection Status LED InfiniBand Port LEDs LIM Status LEDsInterpreting the LIM Status LEDs Monitor the Device Monitoring the System with Chassis ManagerInterpreting the InfiniBand Port LEDs Device Rear View and the Device Front View appear Page Monitor the Cards 12Chassis Manager Cards WindowMonitor the InfiniBand Ports 13Chassis Manager Ports WindowMonitor the Power Supplies 14Chassis Manager Port Properties Dialog Box15Chassis Manager Power Supplies Window Monitor the FansMonitor the Temperature 17Chassis Manager Sensors WindowMonitoring the System with Element Manager Interpreting the Summary TabInterpreting the Fans Tab Interpreting the Power Supplies TabInterpreting the Sensors Tab Monitor the Power Supplies Show power-supplyMonitor the System With the CLI Monitor the FansShow sensor Monitor the SensorsSFS-270#show sensor Page LED Tests About Diagnostic TestsSelf Tests Run Card Tests SFS-270#show diagnostic cardRun a Card Self-Test SFS-270config-diag-card-11# exit SFS-270config# exit Run Chassis Tests More sysloghwiflogRun a Chassis Standard Test SFS-270config#diag chassis test standardSFS-270#show diag chassis Run a Self-Test on a Fan Run Fan TestsTS270-1#show diag post Enter the diag fan id command Run Power Supply Tests Run a LED Test on the Power SupplyRun a Self-Test on a Power Supply SFS-270#show power-supplySFS-270config#diag power-supply SFS-270#show diag power-supplyRun a Rack Locator Test 100Enable Displaying Hardware ErrorsSFS-270show diag rack-locator SFS-270#show diagnostic post SFS-270#show diagnostic fru-errorSpecifications and Compliance Certifications Chassis and Management InterfaceElectrical Specifications SafetyEMC/Immunity AcousticsProduct Markings 108 Index

270, 7008 specifications

Cisco Systems 7008,270 is a powerful model in the Cisco portfolio, showcasing cutting-edge technology aimed at meeting the demands of modern networking environments. Ideal for both enterprise and service provider applications, the 7008,270 offers exceptional flexibility, scalability, and performance.

One of the standout features of this device is its high-density interface options. The 7008,270 supports a mix of Ethernet speeds, including 1G, 10G, and 25G, enabling organizations to optimize their network infrastructure based on specific needs. This versatility provides businesses with seamless transition capabilities as they scale their operations, ensuring that they are always equipped with the right bandwidth.

In terms of performance, the Cisco 7008,270 boasts advanced processing power, allowing for swift data packet handling and reduced latency. The implementation of Enhanced IP Multicast is another key feature, which allows for efficient data delivery to multiple endpoints simultaneously. This is particularly beneficial for organizations that rely heavily on video conferencing and streaming services, as it enhances the overall quality of experience for end-users.

Additionally, the 7008,270 integrates Cisco's advanced security protocols. With features such as TrustSec and the ability to implement micro-segmentation, organizations can ensure that their data remains secure across the network. Cisco's Software-Defined Access (SD-Access) technology further simplifies network management by allowing for automated policy enforcement and enhanced visibility into network traffic.

Another notable characteristic is the seamless integration with existing Cisco platforms and software solutions. The 7008,270 works effectively with Cisco DNA (Digital Network Architecture), allowing businesses to leverage AI-driven analytics and insights to manage performance and security in real-time.

Energy efficiency is also a consideration with the 7008,270. The design includes energy-saving features, which not only reduce operational costs but also support sustainability initiatives within organizations. With an eye towards future-proofing, Cisco Systems has equipped the 7008,270 with options for software upgrades, enabling businesses to continuously enhance their capabilities without needing to replace hardware.

In conclusion, Cisco Systems 7008,270 stands out as a robust networking solution designed for scalability, security, and performance in diverse environments. Its flexibility in interface options, advanced processing power, and strong integration capabilities make it an excellent choice for organizations looking to fortify their network infrastructure and prepare for future demands.