Cisco Systems 7008, 270 manual Optional Launch the Chassis Manager, Prepare Your Device

Page 32

32

Command Line Interface (CLI) - a text-based interface accessible through a direct serial connection, Telnet over IP, or SSH over IP.

Chassis Manager (GUI) - A web-based graphic user interface.

Element Manager (GUI) - An optionally available graphic interface installed on a workstation, and accessible over IP.

Refer to the InfiniBand User Guide, the CLI Reference Guide or the Chassis Manager User Guide for more information about managing the InfiniBand systems.

(Optional) Launch the Chassis Manager

Chassis Manager is a web-based GUI that can be used to manage a single InfiniBand chassis.

Prepare Your Device

To launch Chassis Manager on your Topspin 270/Cisco SFS 7008, you must:

Configure an IP address on the Ethernet management port, if you have not already done so.

Configure an IP gateway on the Ethernet management port, if you have not already done so.

Optional. Enable Telnet services (should be enabled by default).

Optional. Enable HTTP or HTTPs services (HTTP should be enabled by default).

If you followed the previous steps, you should already have these items configured. If your device meets these requirements, proceed to “Launch Chassis Manager” on page 32. Otherwise, to prepare your device, perform the following steps:

NOTE: Consult your network administrator for an IP address, subnet mask, and gateway address before you begin this process.

1.If you have not yet configured an IP address for the Management port, refer to “Configure Basic Connectivity” on page 29.

2.Enter the telnet enable command in global config mode to start telnet services on your device. You may need to use the exit command to return to global config mode.

Example

SFS-270> enable

SFS-270# configure

SFS-270(config)# telnet enable

3.Enter the ip http server command to enable HTTP services on your device. HTTPs is also supported.

Example

SFS-270(config)# ip http server

Launch Chassis Manager

To launch Chassis Manager, perform the following steps:

1.Launch your Web browser.

Chassis Manager supports the following browsers

Microsoft Internet Explorer version 6

Netscape Navigator version 6

Image 32
Contents Topspin 270/Cisco SFS 7008 Hardware Guide Release Page Regulatory Notices Vii Managing Individual Components Monitoring the Topspin 270/Cisco SFS 109 FCC Statement Safety Information Electrical CautionsViii Contact Information General CautionsPage System Architecture Hot StandbyInfiniBand Connectivity FlexibilityHi-Availability HardwareDiagram of the Chassis About the Topspin 270/Cisco SFS 7008 ChassisNon-Blocking Architecture Fabric2Back Chassis View Chassis Slot Numbering 3Chassis Slot Numbering in Front Non-port SideDimensions Power SuppliesConnections LEDsFan Trays Management Interface ModulesFabric Controller Modules Node and Core SlotsMaster/Slave and Standby Roles Node SlotRack Alarm Line Interface Modules LIMChassis ID Module How the Chassis ID is UsedAdministrative Features Prepare the Site Read the Cautionary StatementsRequirements Rack Mount InstallationMount the Topspin 270/Cisco SFS 7008 Chassis in a Rack 1Install Appropriate Rack in Shelf 2Unscrew Extra Rack Ears from the Chassis 4Rack Ears Flush with Rails Attach a Serial Console Cable to a PC or Terminal Install Optional HA ComponentsConnect Management Devices Baud 9600 bps Recommended Management ConfigurationConnect an Ethernet Cable to the Ethernet Management Port Power on the Chassis 8Power Jack Locations Configure Basic Connectivity Enter the interface mgmt-ethernet command SFS-270config#interface mgmt-ethernet SFS-270#copy running-config startup-configAssigning an Address Dynamically About ConnectorsConnect Network Devices Connecting InfiniBand Devices Manage the SystemLaunch Chassis Manager Optional Launch the Chassis ManagerPrepare Your Device 10Web Browser Window Optional Install the Element Manager GUI About the Field Replaceable Units Power Supply ModulesAbout the Power Supply Modules Locating the Power Supply Module Removing a Power Supply ModuleAbout a Failed Power Supply Power Cord back Power Supply front Installing a New Power Supply Module 3Pulling the Power Supply Module from the BayFan Tray Modules About the Fan Tray ModulesRemoving a Fan Module About a Failed Fan Tray5Loosening Captive Screws Installing a Fan Module 7Pushing Fan Module into SlotRemoving a Fabric Controller Fabric ControllersAbout the Fabric Controllers 9Loosen Captive Screws Before Removing Installing a Fabric Controller Upgrading the Controller CardRemoving a LIM Card Line Interface Management Modules LIMAbout LIM Cards 12Removing a Pinch-Type Connector 14Loosen the Captive Screws Installing a LIM Module 17Closing the LIM Module LeversManagement Interface Modules About Management Interface ModulesRemoving a Management Interface Module About a Failed Management Interface ModuleInstalling a Management Interface Module Chassis ID ModulesAbout Chassis ID Modules Removing a Chassis ID Module20Loosen the Captive Screws Installing a Replacement Chassis ID Module Upgrade all Cards in a Chassis Upgrading a Topspin 270/Cisco SFS 7008 with the CLIFile Type = Image Select Maintenance File ManagementUpgrading a Topspin 270/Cisco SFS 7008 with Element Manager Select Maintenance Boot Config 2Watching the File Copy ProgressUpgrading an Individual Controller Card Select View Device Front ViewUpgrading a Controller Card with the CLI Show the standby Controller card Upgrading Individual Node Cards Upgrading a Node Card with the CLI5Copy the .img File to Server Switch Upgrading a Node Card with Element Manager6Watching the File Copy Progress 8Disable and Enable the Node Cards Upgrading Node Cards with the Chassis Manager Upgrade a New Fabric Controller Module with the CLIUpgrading a New Fabric Controller Module SFS-270#reload no-failover SFS-270#install imageOS-image-230.imgPrimary-boot-image keyword Upgrade a New Fabric Controller Module with Element Manager Page Monitoring the Topspin 270/Cisco SFS 7008 System Interpreting the Front Panel LEDsInterpreting the System Status LED System-Wide Status LEDLocating the System-Wide Status LED Power Supply LEDs Locating the Power Supply LEDsConfig mode diag power-supply Test ledInterpreting the Power Supply LEDs 3Power Supply Identify LEDConfig mode -power-supply Config mode -diag fanFan LEDs LocationModule Active System Master Indicator Status Active Master Status IndicatorFabric Controller LEDs Interpreting the Fabric Controller LEDsInterpreting the Back Panel LEDs Management Interface Module LEDsManagement Interface Status LEDs Interpreting the Management Interface LEDsSystem Status LEDs Power Supply Module Status LEDs Fan Tray Module Status LEDsMaster Management Connection Status LED Ethernet Management Port RJ-45 connector LEDsChassis ID LEDs Interpreting the LIM Status LEDs LIM Status LEDsInfiniBand Port LEDs Interpreting the InfiniBand Port LEDs Monitoring the System with Chassis ManagerMonitor the Device Device Rear View and the Device Front View appear Page Monitor the Cards 12Chassis Manager Cards WindowMonitor the InfiniBand Ports 13Chassis Manager Ports WindowMonitor the Power Supplies 14Chassis Manager Port Properties Dialog Box15Chassis Manager Power Supplies Window Monitor the FansMonitor the Temperature 17Chassis Manager Sensors WindowMonitoring the System with Element Manager Interpreting the Summary TabInterpreting the Sensors Tab Interpreting the Power Supplies TabInterpreting the Fans Tab Monitor the Power Supplies Show power-supplyMonitor the System With the CLI Monitor the FansSFS-270#show sensor Monitor the SensorsShow sensor Page Self Tests About Diagnostic TestsLED Tests Run a Card Self-Test SFS-270#show diagnostic cardRun Card Tests SFS-270config-diag-card-11# exit SFS-270config# exit Run Chassis Tests More sysloghwiflogSFS-270#show diag chassis SFS-270config#diag chassis test standardRun a Chassis Standard Test TS270-1#show diag post Run Fan TestsRun a Self-Test on a Fan Enter the diag fan id command Run Power Supply Tests Run a LED Test on the Power SupplyRun a Self-Test on a Power Supply SFS-270#show power-supplySFS-270config#diag power-supply SFS-270#show diag power-supplyRun a Rack Locator Test 100SFS-270show diag rack-locator Displaying Hardware ErrorsEnable SFS-270#show diagnostic post SFS-270#show diagnostic fru-errorSpecifications and Compliance Certifications Chassis and Management InterfaceElectrical Specifications SafetyEMC/Immunity AcousticsProduct Markings 108 Index