Chapter 7 Maintaining the Cisco Catalyst 5500 Multiswitch Router

Checking Equipment Status

Table 7-1 Supervisor Engine III and Uplink Module LED Descriptions (continued)

LED

State

Description

 

 

 

SLOT 1

On

Supervisor Engine III only: The Flash PC Card SLOT 1 and SLOT 0

and

 

LEDs light when their respective slot 1 and slot 0 Flash PC Card devices

SLOT 0

 

are accessed.

 

 

 

100 Mbps

Green

The port is operating at 100 Mbps.

 

 

 

1000 Mbps

Green

The port is operating at 1000 Mbps.

 

 

 

LINK

Green

The port is operational.

 

Orange

The link has been disabled by software.

 

Flashing

The link is bad and has been disabled due to a hardware failure.

 

orange

 

 

Off

No signal is detected.

 

 

 

Ethernet Switching Module (10BaseT 24 Port) LEDs

Each switching module (Prod # WS-X5013) contains a STATUS LED. When on, this LED indicates that the switching module is operational and is powered up. It does not necessarily mean that the interface ports are functional or enabled.

The LEDs on the faceplate of the Ethernet switching module (10BaseT 24 Port) are described in Table 7-2and shown in Figure 7-2.

Table 7-2 Ethernet Switching Module (10BaseT 24 Port) LED Descriptions

LED

Description

 

 

STATUS

The switch performs a series of self-tests and diagnostic tests.

 

If it passes all the tests, the status LED is green.

 

If it fails any test, the status LED is red (or orange for a minor fault or if manually

 

disabled).

 

 

Link

If the port is operational (a signal is detected), the LED is green.

 

If the link has been disabled by software, the LED is orange.

 

If the link is bad and has been disabled due to a hardware failure, the LED flashes

 

orange.

 

If no signal is detected, the LED is off.

 

 

Figure 7-2 Ethernet Switching Module (10BaseT 24 Port) LEDs

3

6

9

12

15

18

21

24

2

5

8

11

14

17

20

23

1

4

7

10

13

16

19

22

ETHERNET SWITCHING MODULE

H3043

Cisco MGC Software Release 7 Operations, Maintenance, and Troubleshooting Guide

 

OL-0542-06

7-3

 

 

 

Image 3
Contents Cisco Catalyst 5500 LEDs Maintaining the Cisco Catalyst 5500 Multiswitch RouterConsole and Auxiliary ports Supervisor Engine Module LEDsSlot Ethernet Switching Module 10BaseT 24 Port LEDsRSM WS-X5302 LEDs Route Switch Module LEDsRSM Using the Command Line Interface to Check StatusAvoiding Problems When Inserting and Removing Modules Tools RequiredRemoving the Supervisor Engine Replacing the Supervisor Engine Using Flash Memory Pcmcia Cards Supervisor EngineLocating the Flash Memory Card Write-Protection Switch Removing and Replacing the Power SupplyAC-Input Power Supply Front Panels Removing an AC-Input Power SupplyHandling an AC-Input Power Supply Installing an AC-Input Power SupplyRemoving a DC-Input Power Supply DC-Input Power Supply Front Panels 11 Handling a DC Power Supply Installing a DC-Input Power SupplyOL-0542-06 Removing the Fan Assembly Removing and Replacing the Chassis Fan Assembly13 Cisco Catalyst 5500 Chassis Fan Assembly Installing the Fan AssemblyChecking the Installation OL-0542-06