Chapter 7 Maintaining the Cisco Catalyst 5500 Multiswitch Router
Checking Equipment Status
Supervisor Engine Module LEDs
The front panel of the supervisor engine III (product number WS
Figure 7-1 Supervisor Engine III Front Panel
Console and Auxiliary ports
SYSTEM |
|
|
|
|
| 100% |
|
|
|
| ||
|
| ACTIVE | RESET |
|
| SLOT | 1 | PORT 1 | MDIX | PORT 2 | MDIX | |
| STATUS | PS2 |
|
|
|
|
| 0 | 10/100Mbps | 10/100Mbps | ||
|
| FAN |
|
|
|
|
|
|
|
| ||
|
| PS1 |
|
|
|
| SLOT |
| LINK |
| LINK |
|
SUPERVISOR ENGINE I I I |
|
| CONSOLE | AUX | Load |
|
| PCMCIA |
|
|
| |
|
|
|
|
| Switch |
|
| 10/100 FAST ETHERCHANNEL |
|
|
|
Status | Reset | Switch | PCMCIA slots | Uplink ports |
LEDs | button | Load display |
|
|
H10965
The LEDs on the supervisor engine front panel indicate the status of the system, which includes the supervisor engine, the power supplies, and the fan assembly. Table
Table
LED | State | Description |
|
|
|
SYSTEM | Green | Indicates that a series of |
STATUS | Red | System is being booted or is faulty (fails a test or module is disabled). |
| ||
| Orange | Fan modules have failed or redundant power supply is installed, but not |
|
| turned on. |
|
|
|
FAN | Green | The fan is operational. |
| Red | The fan is not operational. |
|
|
|
PS1 | Green | Power supply in left bay is operational. |
| Red | Power supply in left bay is not operational, switched off, or not receiving |
|
| power. |
| Off | Power supply in the left bay is off or not installed. |
|
| Note The Catalyst 5500 power supply LED is red when no modules |
|
| are installed. |
|
|
|
PS2 | Green | The power supply in the right bay is operational. |
| Red | The power supply in the right bay is not operational, is switched off, or |
|
| is not receiving input power. |
| Off | The power supply in the right bay is off or is not installed. |
|
| Note The Catalyst 5500 power supply LED is red when no modules |
|
| are installed. |
|
|
|
SWITCH | If the switch is operational, the switch load display indicates (as an | |
LOAD |
| approximate percentage) the current traffic load over the backplane. |
|
|
|
ACTIVE | Green | The supervisor engine is operational and active. |
| Orange | The supervisor engine module is in standby mode. |
|
|
|
Cisco MGC Software Release 7 Operations, Maintenance, and Troubleshooting Guide
| ||
|