Cisco Systems 5500 manual Removing an AC-Input Power Supply, AC-Input Power Supply Front Panels

Page 9

Chapter 7 Maintaining the Cisco Catalyst 5500 Multiswitch Router

Replacing Hardware Components

Removing an AC-Input Power Supply

Follow these steps to remove an AC-input power supply:

Note In systems with redundant power supplies, the faulty supply can be replaced while the system is operating.

Step 1 Turn off the power switch on the power supply you are removing (see Figure 7-7).

Warning Do not touch the power supply when the power cord is connected. For systems with a power switch, line voltages are present within the power supply even when the power switch is off and the power cord is connected. For systems without a power switch, line voltages are present within the power supply when the power cord is connected.

Caution Failure to turn off the power supply could result in equipment damage.

Figure 7-7 AC-Input Power Supply Front Panels

Power connection

AC

FAN

OUTPUT

OK

OK

FAIL

 

Metal prongs

o

Power switch

Captive screw

H11764

Step 2 Disconnect the power cord from the power source.

Warning Before working on a chassis or working near power supplies, unplug the power cord on AC units; disconnect the power at the circuit breaker on DC units.

Step 3 Disconnect the power cord from the power supply being removed.

Step 4 Using a flat-blade screwdriver, loosen and remove the captive installation screws (see Figure 7-7).

Caution Use both hands to install and remove power supplies.

Step 5 Grasp the power supply handle with one hand and place your other hand underneath to support the bottom of the supply, as shown in Figure 7-8(Cisco Catalyst 5000 supply shown).

Cisco MGC Software Release 7 Operations, Maintenance, and Troubleshooting Guide

 

OL-0542-06

7-9

 

 

 

Image 9
Contents Cisco Catalyst 5500 LEDs Maintaining the Cisco Catalyst 5500 Multiswitch RouterConsole and Auxiliary ports Supervisor Engine Module LEDsSlot Ethernet Switching Module 10BaseT 24 Port LEDsRSM WS-X5302 LEDs Route Switch Module LEDsRSM Using the Command Line Interface to Check StatusAvoiding Problems When Inserting and Removing Modules Tools RequiredRemoving the Supervisor Engine Replacing the Supervisor Engine Using Flash Memory Pcmcia Cards Supervisor EngineLocating the Flash Memory Card Write-Protection Switch Removing and Replacing the Power SupplyAC-Input Power Supply Front Panels Removing an AC-Input Power SupplyHandling an AC-Input Power Supply Installing an AC-Input Power SupplyRemoving a DC-Input Power Supply DC-Input Power Supply Front Panels 11 Handling a DC Power Supply Installing a DC-Input Power SupplyOL-0542-06 Removing the Fan Assembly Removing and Replacing the Chassis Fan Assembly13 Cisco Catalyst 5500 Chassis Fan Assembly Installing the Fan AssemblyChecking the Installation OL-0542-06