Cisco Systems 5500 manual Route Switch Module LEDs, RSM WS-X5302 LEDs

Page 4

Chapter 7 Maintaining the Cisco Catalyst 5500 Multiswitch Router

Checking Equipment Status

10/100 Mbps Fast Ethernet Switching Module (10/100BaseTX 12 Port) LEDs

The faceplate of each 10/100 Mbps Fast Ethernet Switching Module (Prod # WS-X5203) contains a module STATUS LED, and two LEDs for each switching port. The LEDs provide status information for the module and individual Fast Ethernet interface connections. The LEDs are described in Table 7-3and are shown in Figure 7-3.

Table 7-3 10/100 Mbps Fast Ethernet Switching Module (10/100BaseTX 12 Port) LEDs

LED

Description

STATUS

The switch performs a series of self-tests and diagnostic tests.

 

If it passes all the tests, the LED is green.

 

If it fails a test other than an individual port test fails, the LED is red.

 

During system boot or if the module is disabled, the LED is orange.

 

During self-test diagnostics, the LED is orange.

 

If the module is disabled, the LED is orange.

 

 

100 Mbps

If the port is operating at 100 Mbps, the LED is green.

 

If the port is operating at 10 Mbps, the LED is off.

LINK (bottom LED)

If the port is operational (a signal is detected), the LED is green.

If the link has been disabled by software, the LED is orange.

If the link is bad and has been disabled due to a hardware failure, the LED flashes orange.

If no signal is detected, the LED is off.

Figure 7-3 10/100 Mbps Fast Ethernet Switching Module (10/100BaseTX 12 Port) LEDs

STATUS

100

Mbps

 

 

 

LINK

10/100 Mbps FAST ETHERNET SWITCHING MODULE

1

2

100

Mbps

 

LINK

H5796

Route Switch Module LEDs

The RSM (product number WS-X5302) LEDs, shown in Figure 7-4, are described in Table 7-3.

Figure 7-4 RSM (WS-X5302) LEDs

STATUS

HALT

CPU

 

ENABLED

ROUTE SWITCH MODULE

PCMCIA

SLOT 0

RESET

CHANNEL

0

TX

CHANNEL

1

 

TX

 

1

 

 

 

 

 

AUX

 

 

 

 

 

 

 

 

SLOT

 

 

 

RX

 

RX

H10366

Cisco MGC Software Release 7 Operations, Maintenance, and Troubleshooting Guide

7-4

OL-0542-06

 

 

Image 4
Contents Maintaining the Cisco Catalyst 5500 Multiswitch Router Cisco Catalyst 5500 LEDsSupervisor Engine Module LEDs Console and Auxiliary portsEthernet Switching Module 10BaseT 24 Port LEDs SlotRoute Switch Module LEDs RSM WS-X5302 LEDsUsing the Command Line Interface to Check Status RSMTools Required Avoiding Problems When Inserting and Removing ModulesRemoving the Supervisor Engine Using Flash Memory Pcmcia Cards Supervisor Engine Replacing the Supervisor EngineRemoving and Replacing the Power Supply Locating the Flash Memory Card Write-Protection SwitchRemoving an AC-Input Power Supply AC-Input Power Supply Front PanelsInstalling an AC-Input Power Supply Handling an AC-Input Power SupplyRemoving a DC-Input Power Supply DC-Input Power Supply Front Panels Installing a DC-Input Power Supply 11 Handling a DC Power SupplyOL-0542-06 Removing and Replacing the Chassis Fan Assembly Removing the Fan AssemblyInstalling the Fan Assembly 13 Cisco Catalyst 5500 Chassis Fan AssemblyChecking the Installation OL-0542-06