Cisco Systems 5500 manual Removing and Replacing the Power Supply

Page 8

Chapter 7 Maintaining the Cisco Catalyst 5500 Multiswitch Router

Replacing Hardware Components

Note You can insert and remove the Flash memory card with the power on.

Before you install a card, verify that the Flash memory card is set with write protection off. The write-protect switch is located on the front edge of the card when oriented with the printing right side up and the edge connector end away from you. (See Figure 7-6.)

Figure 7-6 Locating the Flash Memory Card Write-Protection Switch

 

Flash PC card

Flash PC card

shown with write

write protection

protection off

H2352

Flash PC card

Use the following procedure for installing and removing a Flash memory card:

Step 1 Face the front panel of the switch and hold the Flash memory card with the connector end of the card toward the slot. The connector end of the card is opposite the end with the write-protection switch, which is shown in Figure 7-6.

Step 2 Insert the card into the appropriate slot until the card completely seats in the connector at the back of the slot and the eject button pops out toward you. Note that the card does not insert all the way into the slot; a portion of the card remains outside the slot. Do not attempt to force the card past this point.

Step 3 To eject a card, press the appropriate ejector button until the card is free of the connector at the back of the slot.

Step 4 Remove the card from the slot and place it in an antistatic bag.

Removing and Replacing the Power Supply

This section describes the procedure you use to remove and install power supplies for the Cisco Catalyst 5500 switches. Use a flat-blade screwdriver to perform these procedures.

Removing an AC-Input Power Supply, page 7-9

Installing an AC-Input Power Supply, page 7-10

Removing a DC-Input Power Supply, page 7-11

Installing a DC-Input Power Supply, page 7-13

Cisco MGC Software Release 7 Operations, Maintenance, and Troubleshooting Guide

7-8

OL-0542-06

 

 

Image 8
Contents Maintaining the Cisco Catalyst 5500 Multiswitch Router Cisco Catalyst 5500 LEDsSupervisor Engine Module LEDs Console and Auxiliary portsEthernet Switching Module 10BaseT 24 Port LEDs SlotRoute Switch Module LEDs RSM WS-X5302 LEDsUsing the Command Line Interface to Check Status RSMRemoving the Supervisor Engine Avoiding Problems When Inserting and Removing ModulesTools Required Using Flash Memory Pcmcia Cards Supervisor Engine Replacing the Supervisor EngineRemoving and Replacing the Power Supply Locating the Flash Memory Card Write-Protection SwitchRemoving an AC-Input Power Supply AC-Input Power Supply Front PanelsInstalling an AC-Input Power Supply Handling an AC-Input Power SupplyRemoving a DC-Input Power Supply DC-Input Power Supply Front Panels Installing a DC-Input Power Supply 11 Handling a DC Power SupplyOL-0542-06 Removing and Replacing the Chassis Fan Assembly Removing the Fan AssemblyInstalling the Fan Assembly 13 Cisco Catalyst 5500 Chassis Fan AssemblyChecking the Installation OL-0542-06