Appendix C Connecting to DC Power
Wiring the
Figure C-13 Completed Wiring of Terminal Block Plug
1 |
2 |
3 |
4 |
132850
1 | Return (positive) Feed A | 3 | Return (positive) Feed B |
|
|
|
|
2 | Supply (negative) Feed A | 4 | Supply (negative) Feed B |
|
|
|
|
Step 8 Insert the terminal block plug in the terminal block header on the front panel of the switch. (See Figure
Caution Secure the wires coming in from the terminal block so that they cannot be disturbed by casual contact. For example, use tie wraps to secure the wires to the rack.
Figure C-14 Inserting the Terminal Block in the Block Header
SYSTEM
+ | + |
|
A |
| |
B |
| |
INPUT |
| |
|
| |
– | ||
CURRENT |
| |
| 2 – 1A |
CONSOLE
132851
Step 9 Remove the tape from the
Cisco ME 3400 Ethernet Access Switch Hardware Installation Guide
| ||
|