Cisco Systems 3560-E, 3750-E manual OL-9774-03

Page 32

Chapter 2 Switch Installation

Preparing for Installation

Warning To prevent the switch from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of 113°F (45°C). To prevent airflow restriction, allow at least 3 inches (7.6 cm) of clearance around the ventilation openings. Statement 17B

Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. Statement 43

Warning Do not stack the chassis on any other equipment. If the chassis falls, it can cause severe bodily injury and equipment damage. Statement 48

Warning An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Be sure that no exposed portion of the DC-input power source wire extends from the terminal block plug. Statement 122

Warning Ethernet cables must be shielded when used in a central office environment. Statement 171

Warning Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed circuitry could constitute an energy hazard. Statement 206

Warning If a redundant power system (RPS) is not connected to the switch, install an RPS connector cover on the back of the switch. Statement 265

Warning Voice over IP (VoIP) service and the emergency calling service do not function if power fails or is disrupted. After power is restored, you might have to reset or reconfigure equipment to regain access to VoIP and the emergency calling service. In the USA, this emergency number is 911. You need to be aware of the emergency number in your country. Statement 361

Warning Attach only the following Cisco RPS model to the RPS receptacle: RPS 2300. Statement 370

Warning Read the wall-mounting instructions carefully before beginning installation. Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system. Statement 378

Warning Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001

Catalyst 3750-E and Catalyst 3560-E Switch Hardware Installation Guide

2-2

OL-9774-03

 

 

Image 32
Contents Americas Headquarters Text Part Number OL-9774-03Page N T E N T S Connecting Devices to the Ethernet Ports Wiring the DC-Input Power Source Accessing the CLI Through the Console Port C-1 Conventions AudiencePurpose Related Publications ViiiPreface OL-9774-03 Switch Models Part Number DescriptionSwitch Part Number Description Front Panel Description24- and 48-Port Switch Front Panel 10/100/1000 Ethernet Ports PoE PortsCisco TwinGig Converter Module Gigabit Ethernet Module SlotsSFP Modules 24- and 48-Port Switch LEDs LEDsSystem LED Color System StatusPower Supply LEDs Master LEDColor RPS Status ColorPort LEDs and Modes Mode LED Port Mode DescriptionFan LED Port Mode Port LED Color Meaning PoE LED Color PoE StatusStack LED Stack LED24- and 48-Port Switch Rear Panel Rear Panel DescriptionCatalyst 3560E-12D Switch Rear Panel StackWise PortsPower-Supply Modules 48-Port Switch Power-Supply ModulesSwitch Port PoE Port non-PoE Port Non-PoEAC-Power-Supply Module LEDs DC-Power-Supply Module LEDs DescriptionFan Modules Module LEDs DescriptionRPS Connector Management PortsManagement Options Network Configurations Preparing for Installation Safety WarningsOL-9774-03 Switch Installation Preparing for Installation Statement 371-Power Cable and AC Adapter Tools and Equipment Installation GuidelinesBox Contents Planning a Switch Stack Catalyst 3750-E Switches Switch Stacking GuidelinesStack Cabling Configurations Stack Bandwidth and Partitioning Examples Example of a Stack with Full Bandwidth ConnectionsPower On Sequence for Switch Stacks Example of a Stack with a Failover ConditionInstalling the Switch Rack-MountingRack-Mounting Brackets 10 Removing Screws from the Switch Attaching the Rack-Mount Brackets11 Attaching Brackets for 19-inch Racks Mounting the Switch in a Rack Mounting the Switch in a RackAttaching the Brackets to the Switch for Wall-Mounting Wall-MountingMounting the Catalyst 3560E-12D Switch on a Wall Mounting the Catalyst 3560E-12SD Switch on a Wall After Installing the Switch Table- or Shelf-MountingConnecting to the StackWise Ports Catalyst 3750-E Switches Installing Devices in the 10-Gigabit Ethernet Slots Installing X2 Transceiver Modules and Converter ModulesModule inserted face up Module inserted face down 202046 Installing SFP Modules Removing an X2 Transceiver Module or Converter ModuleInstalling an SFP Module Lower SFP modules are inverted on 24- and 48-port switches Connecting Devices to the Ethernet Ports Removing an SFP ModuleDevice Crossover Cable 10/100/1000 Ethernet Port ConnectionsPoE Port Connections Switch Installation Connecting Devices to the Ethernet Ports Where to Go Next OL-9774-03 Power Supply and Fan Module Installation Installation OverviewOL-9774-03 Installing an AC-Power Supply Inserting the AC-Power Supply in 24- and 48-Port SwitchesInstalling a DC-Power Supply AC-Power Supply with Power Cord RetainerPreparing for Installation Grounding the SwitchStripping the Ground Wire See -9for the Catalyst 3560E-12SD ground location Installing the DC Power Supply in the Switch Inserting the DC-Power Supply in 24- and 48-Port SwitchesWiring the DC-Input Power Source Installing a Fan Module 12 Inserting the Fan Module in 24- and 48-Port Switches202049 OL-9774-03 Diagnosing Problems Check Switch Post ResultsCheck Switch LEDs Check Switch ConnectionsBad or Damaged Cable Ethernet and Fiber CablesPoE Connections Transceiver IssuesPort and Interface Settings Check Switch Performance Ping End DeviceSpanning Tree Loops Speed, Duplex, and AutonegotiationCabling Distance How to Clear the Switch IP Address and ConfigurationAutonegotiation and NIC Cards Finding the Switch Serial Number How to Replace a Failed Stack MemberTroubleshooting How to Replace a Failed Stack Member OL-9774-03 Physical Specifications Environmental RangesPower Specifications Table A-5 OL-9774-03 Connector and Cable Specifications Connector Specifications10/100/1000 Ports Gigabit Ethernet Module InterfacesFigure B-4 Duplex LC Cable Connector 10/100 Ethernet Management Port Console PortCable and Adapter Specifications Gigabit Ethernet X2 Transceiver Module Cable SpecificationsModal X2 Product Wavelength Core Size Bandwidth Number Microns MHz/kmSFP Module Cable Specifications X2 Product Transmit Power Receive Power NumberTransmit DBm Wavelength nmFour Twisted-Pair Cable Pinouts 652 43.4 to 62 miles 1530 To 100 km 1570 1610Two Twisted-Pair Crossover Cable Schematic Two Twisted-Pair Cable PinoutsSwitch Console RJ-45-to-DB-9 Port DTE Identifying a Crossover CableConsole Port Adapter Pinouts DeviceSwitch Console RJ-45-to-DB-25 Port DTE Accessing the CLI Through the Console Port Accessing the CLIAccessing the CLI Through Express Setup Connecting to the Console Port Entering the Initial Configuration InformationIP Settings Completing the Setup Program Line vty 0 These choices appear OL-9774-03 Numerics IN-2 IN-3 IN-4 IN-5 IN-6
Related manuals
Manual 20 pages 4.95 Kb

3750-E, 3560-E specifications

Cisco Systems RPS (Redundant Power System) 2300, along with the 3750-E and 3560-E series switches, represents a significant technological advancement in enterprise networking. These devices are designed to enhance network reliability, scalability, and efficiency, making them integral components in modern enterprise infrastructures.

The Cisco RPS 2300 is designed to provide redundant power to specified Cisco switches, ensuring continuous operation during power disruptions. This system can support up to six devices, enhancing power reliability and reducing downtime. The modularity of the RPS 2300 contributes to its flexibility, allowing enterprises to customize their power solutions to suit their networking needs. It features dual power input, which provides an additional layer of failover capability, ensuring that even in the event of a primary power failure, the backup power system can take over seamlessly.

On the other hand, the Cisco 3750-E series switches are enterprise-class devices that offer a rich feature set to support advanced network functions. These switches come with Cisco’s StackWise technology, enabling users to stack up to nine switches in a single logical unit. This increases port density and simplifies network management. The 3750-E also supports Power over Ethernet (PoE), allowing the delivery of power directly to devices like IP phones and access points through the networking cables. The switch is equipped with high-performance Layer 3 routing capabilities, providing enhanced IP routing options for enterprise networks.

The Cisco 3560-E series switches share many of the advanced features found in the 3750-E models but focus more on providing comprehensive Layer 2 and Layer 3 capabilities in a compact design. The 3560-E series supports Cisco’s advanced security features, such as dynamic VLAN assignment and security group access control lists (ACLs). Additionally, these switches support IPv6, preparing enterprise networks for future growth and addressing requirements.

Both the 3750-E and 3560-E are equipped with energy-efficient technologies, including intelligent power management and support for Energy Efficient Ethernet (EEE), helping organizations reduce their environmental footprint and operating costs. The integration of Cisco’s robust IOS software ensures that these devices are equipped with the latest features, ensuring strong performance, security, and scalability.

In summary, Cisco's RPS 2300, 3750-E, and 3560-E series exemplify the company's commitment to delivering cutting-edge networking solutions that meet the demands of modern enterprises, focusing on reliability, advanced features, and energy efficiency.