Entering the Initial Configuration Information

Step 7 Enter the interface name (physical interface or VLAN name) of the interface that connects to the management network, and press Return. For this release, always use vlan1 as that interface.

Enter interface name used to connect to the

management network from the above interface summary: vlan1

Step 8 Configure the interface by entering the switch IP address and subnet mask and pressing Return. The IP address and subnet masks shown are examples.

Configuring interface vlan1:

Configure IP on this interface? [yes]: yes

IP address for this interface: 10.4.120.106

Subnet mask for this interface [255.0.0.0]: 255.0.0.0

Step 9 Enter Y to configure the switch as the cluster command switch. Enter N to configure it as a member switch or as a standalone switch.

If you enter N, the switch appears as a candidate switch in the Network Assistant GUI. You can configure the switch as a command switch later through the CLI, the device manager, or the Network Assistant application. To configure it later, enter no.

Would you like to enable as a cluster command switch? [yes/no]: no

You have now completed the initial configuration of the switch, and the switch displays its initial configuration. This is an example of output that appears:

The following configuration command script was created: hostname switch1

enable secret 5 $1$Ulq8$DlA/OiaEbl90WcBPd9cOn1 enable password enable_password

line vty 0 15

password terminal-password no snmp-server

!

no ip routing

!

interface Vlan1 no shutdown

ip address 10.4.120.106 255.0.0.0

!

interface GigabitEthernet1/0/1

!

interface GigabitEthernet1/0/2

interface GigabitEthernet1/0/3

!

...<output abbreviated>

!

interface GigabitEthernet1/0/23

!

end

Catalyst 3750-E and Catalyst 3560-E Switch Hardware Installation Guide

 

C-4

OL-9774-03

 

 

 

Image 98
Contents Americas Headquarters Text Part Number OL-9774-03Page N T E N T S Connecting Devices to the Ethernet Ports Wiring the DC-Input Power Source Accessing the CLI Through the Console Port C-1 Conventions AudiencePurpose Related Publications ViiiPreface OL-9774-03 Switch Models Part Number DescriptionSwitch Part Number Description Front Panel Description24- and 48-Port Switch Front Panel 10/100/1000 Ethernet Ports PoE PortsCisco TwinGig Converter Module Gigabit Ethernet Module SlotsSFP Modules 24- and 48-Port Switch LEDs LEDsSystem LED Color System StatusColor RPS Status Power Supply LEDsMaster LED ColorPort LEDs and Modes Mode LED Port Mode DescriptionFan LED Port Mode Port LED Color Meaning PoE LED Color PoE StatusStack LED Stack LED24- and 48-Port Switch Rear Panel Rear Panel DescriptionCatalyst 3560E-12D Switch Rear Panel StackWise PortsSwitch Power-Supply Modules48-Port Switch Power-Supply Modules Port PoE Port non-PoE Port Non-PoEAC-Power-Supply Module LEDs DC-Power-Supply Module LEDs DescriptionFan Modules Module LEDs DescriptionRPS Connector Management PortsManagement Options Network Configurations Preparing for Installation Safety WarningsOL-9774-03 Switch Installation Preparing for Installation Statement 371-Power Cable and AC Adapter Tools and Equipment Installation GuidelinesBox Contents Planning a Switch Stack Catalyst 3750-E Switches Switch Stacking GuidelinesStack Cabling Configurations Stack Bandwidth and Partitioning Examples Example of a Stack with Full Bandwidth ConnectionsPower On Sequence for Switch Stacks Example of a Stack with a Failover ConditionInstalling the Switch Rack-MountingRack-Mounting Brackets 10 Removing Screws from the Switch Attaching the Rack-Mount Brackets11 Attaching Brackets for 19-inch Racks Mounting the Switch in a Rack Mounting the Switch in a RackAttaching the Brackets to the Switch for Wall-Mounting Wall-MountingMounting the Catalyst 3560E-12D Switch on a Wall Mounting the Catalyst 3560E-12SD Switch on a Wall After Installing the Switch Table- or Shelf-MountingConnecting to the StackWise Ports Catalyst 3750-E Switches Installing Devices in the 10-Gigabit Ethernet Slots Installing X2 Transceiver Modules and Converter ModulesModule inserted face up Module inserted face down 202046 Installing SFP Modules Removing an X2 Transceiver Module or Converter ModuleInstalling an SFP Module Lower SFP modules are inverted on 24- and 48-port switches Connecting Devices to the Ethernet Ports Removing an SFP ModuleDevice Crossover Cable 10/100/1000 Ethernet Port ConnectionsPoE Port Connections Switch Installation Connecting Devices to the Ethernet Ports Where to Go Next OL-9774-03 Power Supply and Fan Module Installation Installation OverviewOL-9774-03 Installing an AC-Power Supply Inserting the AC-Power Supply in 24- and 48-Port SwitchesInstalling a DC-Power Supply AC-Power Supply with Power Cord RetainerPreparing for Installation Grounding the SwitchStripping the Ground Wire See -9for the Catalyst 3560E-12SD ground location Installing the DC Power Supply in the Switch Inserting the DC-Power Supply in 24- and 48-Port SwitchesWiring the DC-Input Power Source Installing a Fan Module 12 Inserting the Fan Module in 24- and 48-Port Switches202049 OL-9774-03 Diagnosing Problems Check Switch Post ResultsBad or Damaged Cable Check Switch LEDsCheck Switch Connections Ethernet and Fiber CablesPoE Connections Transceiver IssuesPort and Interface Settings Spanning Tree Loops Check Switch PerformancePing End Device Speed, Duplex, and AutonegotiationCabling Distance How to Clear the Switch IP Address and ConfigurationAutonegotiation and NIC Cards Finding the Switch Serial Number How to Replace a Failed Stack MemberTroubleshooting How to Replace a Failed Stack Member OL-9774-03 Physical Specifications Environmental RangesPower Specifications Table A-5 OL-9774-03 Connector and Cable Specifications Connector Specifications10/100/1000 Ports Gigabit Ethernet Module InterfacesFigure B-4 Duplex LC Cable Connector 10/100 Ethernet Management Port Console PortModal X2 Product Wavelength Core Size Bandwidth Number Cable and Adapter SpecificationsGigabit Ethernet X2 Transceiver Module Cable Specifications Microns MHz/kmTransmit SFP Module Cable SpecificationsX2 Product Transmit Power Receive Power Number DBm Wavelength nmFour Twisted-Pair Cable Pinouts 652 43.4 to 62 miles 1530 To 100 km 1570 1610Two Twisted-Pair Crossover Cable Schematic Two Twisted-Pair Cable PinoutsConsole Port Adapter Pinouts Switch Console RJ-45-to-DB-9 Port DTEIdentifying a Crossover Cable DeviceSwitch Console RJ-45-to-DB-25 Port DTE Accessing the CLI Through the Console Port Accessing the CLI Accessing the CLI Through Express Setup Connecting to the Console Port Entering the Initial Configuration InformationIP Settings Completing the Setup Program Line vty 0 These choices appear OL-9774-03 Numerics IN-2 IN-3 IN-4 IN-5 IN-6