Cisco Systems 3750-E, 3560-E manual Installing an AC-Power Supply

Page 63

Chapter 3 Power Supply and Fan Module Installation

Installing an AC-Power Supply

Installing an AC-Power Supply

To remove and install an AC-powered power-supply module, follow these steps:

Step 1 Turn off the power at its source. For Catalyst 3560E-12D and 3560E-12SD switches, also turn off the power supply on/off switch.

Step 2 If used, detach the power cord retainer assembly from the power cord.

Step 3 Remove the power cord from the power connector.

Step 4 For 24- and 48-port switches, use a Phillips screwdriver to loosen the two captive screws at the lower edge that secure the power supply to the switch chassis (Figure 3-1).

For Catalyst 3560E-12D and 3560E-12SD switches, use a Phillips screwdriver to loosen the captive screw at the left edge of the power supply (Figure 3-2).

Caution Do not leave the power-supply slot open for more than 90 seconds while the switch is operating.

Step 5 Remove the power-supply module from the power slot by pulling on the extraction handle.

Step 6 Insert the new power supply into the power-supply slot, and gently push it into the slot (Figure 3-1and Figure 3-2). When correctly inserted, the power supply is flush with the switch rear panel. The 1150-W power-supply module extends 3.6 inches (9.14 cm) from the switch rear panel.

Figure 3-1 Inserting the AC-Power Supply in 24- and 48-Port Switches

100-240 V 10-5 A

50-60 HZ

AC OK

PS OK

 

158122

Figure 3-2 Inserting the AC-Power Supply in Catalyst 3560E-12D and 3560E-12SD Switches (Catalyst 3560E-12D Switch Shown)

202047

Step 7 For 24- and 48 port switches, align the two captive screws with the screw holes. Using a ratcheting torque screwdriver, torque each screw to 7 lbf-in. (112 ozf-in.).

Catalyst 3750-E and Catalyst 3560-E Switch Hardware Installation Guide

 

OL-9774-03

3-3

 

 

 

Image 63
Contents Text Part Number OL-9774-03 Americas HeadquartersPage N T E N T S Connecting Devices to the Ethernet Ports Wiring the DC-Input Power Source Accessing the CLI Through the Console Port C-1 Audience PurposeConventions Viii Related PublicationsPreface OL-9774-03 Part Number Description Switch ModelsFront Panel Description Switch Part Number Description24- and 48-Port Switch Front Panel PoE Ports 10/100/1000 Ethernet PortsGigabit Ethernet Module Slots SFP ModulesCisco TwinGig Converter Module LEDs 24- and 48-Port Switch LEDsColor System Status System LEDColor Power Supply LEDsMaster LED Color RPS StatusMode LED Port Mode Description Fan LEDPort LEDs and Modes Port Mode Port LED Color Meaning Color PoE Status PoE LEDStack LED Stack LEDRear Panel Description 24- and 48-Port Switch Rear PanelStackWise Ports Catalyst 3560E-12D Switch Rear PanelPort PoE Port non-PoE Port Non-PoE Power-Supply Modules48-Port Switch Power-Supply Modules SwitchDC-Power-Supply Module LEDs Description AC-Power-Supply Module LEDsModule LEDs Description Fan ModulesManagement Ports RPS ConnectorManagement Options Network Configurations Safety Warnings Preparing for InstallationOL-9774-03 Switch Installation Preparing for Installation Statement 371-Power Cable and AC Adapter Installation Guidelines Box ContentsTools and Equipment Switch Stacking Guidelines Planning a Switch Stack Catalyst 3750-E SwitchesStack Cabling Configurations Example of a Stack with Full Bandwidth Connections Stack Bandwidth and Partitioning ExamplesExample of a Stack with a Failover Condition Power On Sequence for Switch StacksRack-Mounting Installing the SwitchRack-Mounting Brackets Attaching the Rack-Mount Brackets 10 Removing Screws from the Switch11 Attaching Brackets for 19-inch Racks Mounting the Switch in a Rack Mounting the Switch in a RackWall-Mounting Attaching the Brackets to the Switch for Wall-MountingMounting the Catalyst 3560E-12D Switch on a Wall Mounting the Catalyst 3560E-12SD Switch on a Wall Table- or Shelf-Mounting After Installing the SwitchConnecting to the StackWise Ports Catalyst 3750-E Switches Installing X2 Transceiver Modules and Converter Modules Installing Devices in the 10-Gigabit Ethernet SlotsModule inserted face up Module inserted face down 202046 Removing an X2 Transceiver Module or Converter Module Installing SFP ModulesInstalling an SFP Module Lower SFP modules are inverted on 24- and 48-port switches Removing an SFP Module Connecting Devices to the Ethernet Ports10/100/1000 Ethernet Port Connections PoE Port ConnectionsDevice Crossover Cable Switch Installation Connecting Devices to the Ethernet Ports Where to Go Next OL-9774-03 Installation Overview Power Supply and Fan Module InstallationOL-9774-03 Inserting the AC-Power Supply in 24- and 48-Port Switches Installing an AC-Power SupplyAC-Power Supply with Power Cord Retainer Installing a DC-Power SupplyGrounding the Switch Preparing for InstallationStripping the Ground Wire See -9for the Catalyst 3560E-12SD ground location Inserting the DC-Power Supply in 24- and 48-Port Switches Installing the DC Power Supply in the SwitchWiring the DC-Input Power Source 12 Inserting the Fan Module in 24- and 48-Port Switches Installing a Fan Module202049 OL-9774-03 Check Switch Post Results Diagnosing ProblemsEthernet and Fiber Cables Check Switch LEDsCheck Switch Connections Bad or Damaged CableTransceiver Issues Port and Interface SettingsPoE Connections Speed, Duplex, and Autonegotiation Check Switch PerformancePing End Device Spanning Tree LoopsHow to Clear the Switch IP Address and Configuration Autonegotiation and NIC CardsCabling Distance How to Replace a Failed Stack Member Finding the Switch Serial NumberTroubleshooting How to Replace a Failed Stack Member OL-9774-03 Environmental Ranges Physical SpecificationsPower Specifications Table A-5 OL-9774-03 Connector Specifications Connector and Cable SpecificationsGigabit Ethernet Module Interfaces 10/100/1000 PortsFigure B-4 Duplex LC Cable Connector Console Port 10/100 Ethernet Management PortMicrons MHz/km Cable and Adapter SpecificationsGigabit Ethernet X2 Transceiver Module Cable Specifications Modal X2 Product Wavelength Core Size Bandwidth NumberDBm Wavelength nm SFP Module Cable SpecificationsX2 Product Transmit Power Receive Power Number Transmit652 43.4 to 62 miles 1530 To 100 km 1570 1610 Four Twisted-Pair Cable PinoutsTwo Twisted-Pair Cable Pinouts Two Twisted-Pair Crossover Cable SchematicDevice Switch Console RJ-45-to-DB-9 Port DTEIdentifying a Crossover Cable Console Port Adapter PinoutsSwitch Console RJ-45-to-DB-25 Port DTE Accessing the CLI Accessing the CLI Through Express SetupAccessing the CLI Through the Console Port Entering the Initial Configuration Information IP SettingsConnecting to the Console Port Completing the Setup Program Line vty 0 These choices appear OL-9774-03 Numerics IN-2 IN-3 IN-4 IN-5 IN-6
Related manuals