Safety Guidelines

Warning When you connect or disconnect the power and relay connector with power applied, an electrical arc can occur. This could cause an explosion in hazardous area installations. Be sure that power is removed from the switch and alarm circuit. Be sure that power cannot be accidentally turned on or verify that the area is nonhazardous before proceeding. Failure to securely tighten the power and relay connector captive screws can result in an electrical arc if the connector is accidentally removed. Statement 1058

Warning Take care when connecting units to the supply circuit so that wiring is not overloaded. Statement 1018

Warning The plug-socket combination must be accessible at all times, because it serves as the main disconnecting device. Statement 1019

Warning To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some LAN and WAN ports both use RJ45 connectors. Use caution when connecting cables. Statement 1021

Warning A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. Statement 1022

Warning To reduce the risk of fire, use only 26 AWG or larger telecommunication line cord. Statement 1023

Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024

Warning Use copper conductors only. Statement 1025

Warning This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028

Warning To prevent personal injury or damage to the chassis, never attempt to lift or tilt the chassis using the handles on modules (such as power supplies, fans, or cards); these types of handles are not designed to support the weight of the unit. Statement 1032

Warning Connect the unit only to DC power source that complies with the safety extra-low voltage (SELV) requirements in IEC 60950 based safety standards. Statement 1033

Cisco ASR 903 Router Hardware Installation Guide

 

OL-25178-05

2-5

 

 

 

Image 39
Contents Cisco ASR 903 Router Hardware Installation Guide Page N T E N T S Site Planning RSP Installation Troubleshooting Fan Tray LEDs Viii Revision Date Change Summary Document Revision HistoryTitle Description Document AudienceDocument Organization Document ConventionsObtaining Documentation and Submitting a Service Request Xii A P T E R Cisco ASR 903 router FeaturesCisco ASR 903 router Chassis Design System SpecificationsPower Supply Features Status LEDs DC Power SpecificationsRedundancy Dying GaspEuro-style connector Fan Tray AC Power SpecificationsFan Tray A903-FAN-E Fan Tray A903-FANDust Filter A903-FAN-F Air PlenumSupported RSPs RSP ModulesRSP Interfaces Supported RSP FeaturesRSP Redundancy Network Timing InterfacesLabel Interface Interface ModulesSupported SFP Modules Gigabit Ethernet SFP Interface ModuleSFP-GE-Z Gigabit Ethernet RJ45 Interface ModuleSupported XFP Modules Gigabit Ethernet XFP Interface ModuleXFP-10GER-OC192IR XFP-10GER-OC192IR-RGD OC-3 Interface Module T1/E1 Interface Module11shows the interface module Serial Interface Module12 Serial Interface Module Standard Definition Supported StandardsTemperature Sensor Interface NumberingSerial Number Label Location Cisco ASR 903 router Overview Regulatory Compliance Regulatory ComplianceOL-25178-05 Safety Guidelines Preparing for InstallationStandard Warning Statements Safety Precautions for Module Installation and Removal Safety with Electricity Page OL-25178-05 Preparing for Installation Safety Guidelines Preventing ESD Damage Power Supply ConsiderationsGeneral Precautions Site Planning ChecklistSite Planning Physical Characteristics Site Selection GuidelinesEnvironmental Requirements Air exhaust Room air Air Flow GuidelinesSite Power Guidelines Air Flow Guidelines for Enclosed Rack InstallationFloor Loading Considerations Site Cabling Guidelines Electrical Circuit RequirementsHardware components Radio Frequency Interference Asynchronous Terminal ConnectionsInterference Considerations Electromagnetic InterferenceRack Selection Guidelines Precautions for Rack-MountingLightning and AC Power Fault Interference Rack-Mounting GuidelinesLocating for Safety Locating for Easy MaintenanceEquipment Rack Guidelines Locating for Proper Airflow Verified Task Date Installation ChecklistCreating a Site Log Receiving the Cisco ASR 903 RouterTools and Equipment Chassis-Lifting GuidelinesUnpacking and Verifying the Shipped Contents Component Description Prerequisites Installing the Router in a RackAttaching Mounting Brackets for a 19-inch EIA Rack Installing the Chassis BracketsInstalling the Chassis in a 19-inch EIA Rack Installing the Router Chassis in the RackInstalling the Chassis in a 300 mm Etsi Cabinet Installing the Chassis in the Air PlenumCisco ASR 903 Chassis with Air Plenum Attaching the Cable Management BracketsCable Management Bracket Installation Grounding lug 300 mm Etsi cabinet Installing the Chassis Ground Connection11 Stripping a Ground Wire 12 Crimping a Ground Lug onto the Ground Wire Installing the Dust Filter Installing the Fan TrayDust Filter Maintenance Removing and Replacing the Fan TrayRemoving the Dust Filter 14 Detaching the Fan Tray 15 Fan Tray Removal RSP Installation16 Cisco ASR 903 Router RSP Installation Installing an RSP ModuleRemoving an RSP Module Hot-Swapping an RSP Module Installing an Interface Module Interface Module InstallationHot-Swapping an Interface Module Removing an Interface ModuleInstalling the Power Supply Preventing Power Loss Power Connection GuidelinesGuidelines for DC-Powered Systems Installing the DC Power Supply Guidelines for AC-Powered SystemsInstalling the DC Power Supply Module 18 Installing the DC Power Supply Installing Terminal Block on the DC PEM Unit A900-PWR550-D19 DC Power Supply with Lead Wires 20 Torquing the DC Power Supply Terminal Block Plug Screws Tools Activating the DC Power Supply Removing and Replacing the DC Power SupplyInstalling the AC power Supply Activating the AC Power Supply Installing the AC Power Supply ModuleSupply has been removed or replaced Removing and Replacing the AC Power SupplyConnecting Console Cables Connecting the Cisco ASR 903 Router to the NetworkConnecting to the Serial Port using Microsoft Windows 2404 Connecting to the Console Port using Mac OS Connecting to the Console Port using LinuxTo disconnect the OS X USB console from the Terminal window Installing the Cisco Microsoft Windows USB Device Driver Installing the Cisco Microsoft Windows XP USB DriverInstalling the Cisco Microsoft Windows 2000 USB Driver Using the Setup.exe Program Uninstalling the Cisco Microsoft Windows USB DriverInstalling the Cisco Microsoft Windows Vista USB Driver Using the Add Remove Programs UtilityUninstalling the Cisco Microsoft Windows Vista USB Driver Connecting to the Auxiliary Port25 Connecting a Modem to the Cisco ASR 903 Router Connecting a Management Ethernet Cable Installing and Removing SFP and XFP ModulesConnecting a USB Flash Device Connecting Timing Cables Connecting Cables to the Bits InterfaceRemoving a USB Flash Device Cisco ASR 903 Router Hardware Installation Guide Connecting Cables to the ToD Interface Connecting Cables to a GPS InterfaceConnecting Cables to the Input 10Mhz or 1PPS Interface Connecting Cables to the Output 10Mhz or 1PPS InterfaceConnecting Ethernet Cables Connecting Cables to SFP Modules Connecting T1/E1 cablesInstalling the Cable Connector RJ45 Cable Pinouts Connecting Cables to the Patch PanelRecommended Patch Panel Connecting Serial CablesEIA/TIA-530 DTE CAB-SS-530FC Cable Type Product Number Length Male/Female ConnectorConnector and Cable Specifications Connecting the Fan Tray Alarm PortOL-25178-05 Checking Conditions Prior to System Startup Cisco ASR 903 Router Initial ConfigurationExample 4-1 Loading the Default System Boot Image Powering Up the Cisco ASR 903 RouterCisco ASR 903 Router Hardware Installation Guide OL-25178-05 CPP Checking Hardware and Software Compatibility Configuring the Cisco ASR 903 Router at StartupVerifying the Hardware Configuration Verifying the Front Panel LEDsConfiguring Global Parameters Using the Console InterfaceSaving the Running Configuration to Nvram Checking the Running Configuration SettingsSafely Powering Off the Cisco ASR 903 Router Pin Signal Name Direction Description PinoutsBits Port Pinout GPS Port Pinout Time of Day Port PinoutMhz input and output 1PPS input and output Alarm Port Pinout Pin Signal Name DescriptionConsole/Aux RJ45 RS232 Serial Port Pinout T1/E1 Port Pinout Board Telco Jack Line PIns Signal Name Pin PinsSerial Cable Pinouts DB-9 Connector Pinouts RJ-45 Connector PinoutsPin Standard DB-9 Direction Description RS-485 Management Ethernet Port Pinout USB Console Port PinoutUSB Flash/MEM Port Pinout Fiber-Optic Specifications LED SummaryRSP LEDs Color/State Description two LEDs for eachT1/E1 port Interface Module LEDsColor/State Description OC-3 Interface Module LEDsT1/E1 Interface Module LEDs Serial Interface Module LEDsLED Label Color/State Meaning Color/State Meaning Power Supply LEDsAlarm Conditions Alarm Type Alarm MeaningFan Tray LEDs OL-25178-05 P E N D I X Site Log and ManufacturesInitials DateManufacturer Web Site or Phone Number Products/Model ManufacturesOL-25178-05 D E IN-2