Chapter 3 Installing the Cisco ASR 903 Router
Installing the Power Supply
•OUTPUT FAIL LED is green
Step 4 If the LEDs indicate a power problem, see the Chapter 5, “Troubleshooting”for troubleshooting information.
Step 5 If you are installing a redundant power supply, repeat these steps for the second power source.
Note If you are installing a redundant AC power supply, ensure that each power supply is connected to a separate power source in order to prevent power loss in the event of a power failure.
Removing and Replacing the AC Power Supply
|
|
|
|
|
| This section describes how to remove and replace the AC power supply. | |||
|
|
|
|
|
|
|
| ||
|
|
| Note | The Cisco ASR 903 Router power supplies are | |||||
|
|
|
|
|
| supply modules, you can replace a single power supply without interrupting power to the router. | |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
|
| Caution | To avoid erroneous failure messages, allow at least 2 minutes for the system to reinitialize after a power | ||||||
|
|
|
|
|
| supply has been removed or replaced. | |||
|
|
|
|
| |||||
|
|
|
|
| |||||
| Warning | When you install the unit, the ground connection must always be made first and disconnected last. | |||||||
|
|
|
|
|
| Statement 1046 | |||
|
|
| |||||||
|
|
|
|
| |||||
| Warning | Before performing any of the following procedures, ensure that power is removed from the DC circuit. | |||||||
|
|
|
|
|
| Statement 1003 | |||
|
|
| |||||||
|
|
|
|
| |||||
| Warning | Only trained and qualified personnel should be allowed to install, replace, or service this equipment. | |||||||
|
|
|
|
|
| Statement 1030 | |||
|
|
| |||||||
|
|
|
|
| |||||
| Warning | Installation of the equipment must comply with local and national electrical codes. Statement 1074 | |||||||
|
|
|
|
|
|
| |||
|
|
|
|
|
| Follow these steps to remove and replace the AC power supply: | |||
|
|
|
|
| |||||
|
|
| Step 1 | Disconnect the power cord from the power source. Do not touch the metal prongs on the power cord | |||||
|
|
|
|
|
| when it is still connected to the power supply. | |||
|
|
| Step 2 | Remove the power cord from the power connection on the power supply. Do not touch the metal prongs | |||||
|
|
|
|
|
| embedded in the power supply. | |||
|
|
| Step 3 | Loosen the captive installation screws. | |||||
|
|
| Step 4 | Grasp the AC power supply with one hand, and slide it part of the way out of the chassis. Place your | |||||
|
|
|
|
|
| other hand underneath the power supply, and slide it completely out of the chassis. | |||
|
|
|
|
|
| Cisco ASR 903 Router Hardware Installation Guide |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|