Cisco Systems ASR 903 manual Removing and Replacing the Fan Tray, Removing the Dust Filter

Page 67

Chapter 3 Installing the Cisco ASR 903 Router

Installing the Fan Tray

Step 3 Slide the dust filter onto the fan tray. See Figure 1-5.

Step 4 Insert the dummy cover on the fan tray to secure the filter within the chassis.

Step 5 Follow the steps to install the fan tray in the chassis. See Installing the Fan Tray, page 3-10.

Removing the Dust Filter

The dust filter must be removed for cleaning or for a replacement.

Dust Filter Maintenance

A periodic health check of the filter, every 3 months based on the level of dust in the environment helps in avoiding over clogging of the filters and provide better life. The product's filter may be used as a single use or reused depending upon the local deployment needs. If reuse of the filter is prohibited, it may be replaced every six months with PID (A903-FAN-F=) or equivalent.

If reused, this filter media may be cleaned with slightly compressed air, vacuumed, and/or rinsed with clean water. If a degreaser is required, use only a mild detergent, such as, dish washing liquid.

Caution Avoid using harsh solvents or cleaning agents.

If filters are cleaned with water, the filters should be completely dry before reinstalling. Even though this type of filter may be cleaned, replacement is recommended every two to three years to ensure media durability and eliminate residual dust build-up and subsequent air flow resistance.

Step 1 Remove the dummy cover from the fan tray.

Step 2 Remove the dust filter from the fan.

Note The filter can be accessed by pulling the pull tab by using fingers or pliers. See Figure 1-5.

Step 3 Slide the replacement dust filter onto the fan tray

Step 4 Insert the dummy cover onto the fan tray to secure the filter within the chassis.

Removing and Replacing the Fan Tray

The fan tray supports online insertion and removal (OIR). There is no need to power down the

Cisco ASR 903 Router to remove or replace the fan tray. However, the router will shut down if the fan tray is removed from the chassis for more than five minutes.

Caution The router can stay active for up to five minutes if the temperature is below the ambient limit. However, in the event of an overtemperature alarm, the router can shut down in less than five minutes. In the event of a critical temperature alarm, the router shuts down immediately.

 

 

Cisco ASR 903 Router Hardware Installation Guide

 

 

 

 

 

 

OL-25178-05

 

 

3-11

 

 

 

 

 

Image 67
Contents Cisco ASR 903 Router Hardware Installation Guide Page N T E N T S Site Planning RSP Installation Troubleshooting Fan Tray LEDs Viii Revision Date Change Summary Document Revision HistoryTitle Description Document AudienceDocument Organization Document ConventionsObtaining Documentation and Submitting a Service Request Xii A P T E R Cisco ASR 903 router FeaturesCisco ASR 903 router Chassis Design System SpecificationsPower Supply Features Status LEDs DC Power SpecificationsRedundancy Dying GaspEuro-style connector Fan Tray AC Power SpecificationsFan Tray A903-FAN-E Fan Tray A903-FANDust Filter A903-FAN-F Air PlenumSupported RSPs RSP ModulesRSP Interfaces Supported RSP FeaturesRSP Redundancy Network Timing InterfacesLabel Interface Interface ModulesSupported SFP Modules Gigabit Ethernet SFP Interface ModuleSFP-GE-Z Gigabit Ethernet RJ45 Interface ModuleSupported XFP Modules Gigabit Ethernet XFP Interface ModuleXFP-10GER-OC192IR XFP-10GER-OC192IR-RGD OC-3 Interface Module T1/E1 Interface Module11shows the interface module Serial Interface Module12 Serial Interface Module Standard Definition Supported StandardsInterface Numbering Temperature SensorSerial Number Label Location Cisco ASR 903 router Overview Regulatory Compliance Regulatory ComplianceOL-25178-05 Safety Guidelines Preparing for InstallationStandard Warning Statements Safety Precautions for Module Installation and Removal Safety with Electricity Page OL-25178-05 Preparing for Installation Safety Guidelines Preventing ESD Damage Power Supply ConsiderationsSite Planning Checklist General PrecautionsSite Planning Site Selection Guidelines Physical CharacteristicsEnvironmental Requirements Air exhaust Room air Air Flow GuidelinesAir Flow Guidelines for Enclosed Rack Installation Site Power GuidelinesFloor Loading Considerations Electrical Circuit Requirements Site Cabling GuidelinesHardware components Radio Frequency Interference Asynchronous Terminal ConnectionsInterference Considerations Electromagnetic InterferenceRack Selection Guidelines Precautions for Rack-MountingLightning and AC Power Fault Interference Rack-Mounting GuidelinesLocating for Easy Maintenance Locating for SafetyEquipment Rack Guidelines Locating for Proper Airflow Verified Task Date Installation ChecklistCreating a Site Log Receiving the Cisco ASR 903 RouterTools and Equipment Chassis-Lifting GuidelinesUnpacking and Verifying the Shipped Contents Component Description Prerequisites Installing the Router in a RackAttaching Mounting Brackets for a 19-inch EIA Rack Installing the Chassis BracketsInstalling the Chassis in a 19-inch EIA Rack Installing the Router Chassis in the RackInstalling the Chassis in a 300 mm Etsi Cabinet Installing the Chassis in the Air PlenumCisco ASR 903 Chassis with Air Plenum Attaching the Cable Management BracketsCable Management Bracket Installation Grounding lug 300 mm Etsi cabinet Installing the Chassis Ground Connection11 Stripping a Ground Wire 12 Crimping a Ground Lug onto the Ground Wire Installing the Dust Filter Installing the Fan TrayRemoving and Replacing the Fan Tray Dust Filter MaintenanceRemoving the Dust Filter 14 Detaching the Fan Tray 15 Fan Tray Removal RSP Installation16 Cisco ASR 903 Router RSP Installation Installing an RSP ModuleRemoving an RSP Module Hot-Swapping an RSP Module Installing an Interface Module Interface Module InstallationHot-Swapping an Interface Module Removing an Interface ModuleInstalling the Power Supply Power Connection Guidelines Preventing Power LossGuidelines for DC-Powered Systems Guidelines for AC-Powered Systems Installing the DC Power SupplyInstalling the DC Power Supply Module 18 Installing the DC Power Supply Installing Terminal Block on the DC PEM Unit A900-PWR550-D19 DC Power Supply with Lead Wires 20 Torquing the DC Power Supply Terminal Block Plug Screws Tools Activating the DC Power Supply Removing and Replacing the DC Power SupplyInstalling the AC power Supply Activating the AC Power Supply Installing the AC Power Supply ModuleSupply has been removed or replaced Removing and Replacing the AC Power SupplyConnecting Console Cables Connecting the Cisco ASR 903 Router to the NetworkConnecting to the Serial Port using Microsoft Windows 2404 Connecting to the Console Port using Linux Connecting to the Console Port using Mac OSTo disconnect the OS X USB console from the Terminal window Installing the Cisco Microsoft Windows XP USB Driver Installing the Cisco Microsoft Windows USB Device DriverInstalling the Cisco Microsoft Windows 2000 USB Driver Using the Setup.exe Program Uninstalling the Cisco Microsoft Windows USB DriverInstalling the Cisco Microsoft Windows Vista USB Driver Using the Add Remove Programs UtilityUninstalling the Cisco Microsoft Windows Vista USB Driver Connecting to the Auxiliary Port25 Connecting a Modem to the Cisco ASR 903 Router Installing and Removing SFP and XFP Modules Connecting a Management Ethernet CableConnecting a USB Flash Device Connecting Cables to the Bits Interface Connecting Timing CablesRemoving a USB Flash Device Cisco ASR 903 Router Hardware Installation Guide Connecting Cables to the ToD Interface Connecting Cables to a GPS InterfaceConnecting Cables to the Input 10Mhz or 1PPS Interface Connecting Cables to the Output 10Mhz or 1PPS InterfaceConnecting Ethernet Cables Connecting T1/E1 cables Connecting Cables to SFP ModulesInstalling the Cable Connector RJ45 Cable Pinouts Connecting Cables to the Patch PanelRecommended Patch Panel Connecting Serial CablesEIA/TIA-530 DTE CAB-SS-530FC Cable Type Product Number Length Male/Female ConnectorConnector and Cable Specifications Connecting the Fan Tray Alarm PortOL-25178-05 Checking Conditions Prior to System Startup Cisco ASR 903 Router Initial ConfigurationExample 4-1 Loading the Default System Boot Image Powering Up the Cisco ASR 903 RouterCisco ASR 903 Router Hardware Installation Guide OL-25178-05 CPP Checking Hardware and Software Compatibility Configuring the Cisco ASR 903 Router at StartupVerifying the Hardware Configuration Verifying the Front Panel LEDsConfiguring Global Parameters Using the Console InterfaceSaving the Running Configuration to Nvram Checking the Running Configuration SettingsSafely Powering Off the Cisco ASR 903 Router Pinouts Pin Signal Name Direction DescriptionBits Port Pinout Time of Day Port Pinout GPS Port PinoutMhz input and output 1PPS input and output Pin Signal Name Description Alarm Port PinoutConsole/Aux RJ45 RS232 Serial Port Pinout T1/E1 Port Pinout Board Telco Jack Line PIns Signal Name Pin PinsSerial Cable Pinouts RJ-45 Connector Pinouts DB-9 Connector PinoutsPin Standard DB-9 Direction Description RS-485 USB Console Port Pinout Management Ethernet Port PinoutUSB Flash/MEM Port Pinout LED Summary Fiber-Optic SpecificationsRSP LEDs Color/State Description two LEDs for eachT1/E1 port Interface Module LEDsColor/State Description OC-3 Interface Module LEDsSerial Interface Module LEDs T1/E1 Interface Module LEDsLED Label Color/State Meaning Color/State Meaning Power Supply LEDsAlarm Type Alarm Meaning Alarm ConditionsFan Tray LEDs OL-25178-05 P E N D I X Site Log and ManufacturesInitials DateManufacturer Web Site or Phone Number Products/Model ManufacturesOL-25178-05 D E IN-2