Cisco Systems ASR 903 manual Equipment Rack Guidelines, Locating for Safety

Page 50

Chapter 2 Preparing for Installation

Site Planning

The distance between the center lines of the mounting holes on the two mounting posts must be 18.31 inches ± 0.06 inch (46.50 cm ± 0.15 cm). The rack-mounting hardware included with the chassis is suitable for most 19-inch equipment racks.

Consider installing the Cisco ASR 903 Router in a rack with the following features:

Network Equipment Building System (NEBS) compliant, 19-inch (48.3 cm) wide rack.

EIA or European Telecommunications Standards Institute (ETSI) hole patterns in the mounting rails. The required mounting hardware is shipped with the Cisco ASR 903 Router. If the rack that you plan to install the system in has metric-threaded rails, you must provide your own metric-mounting hardware.

Perforated top and open bottom for ventilation to prevent overheating.

Leveling feet for stability.

Note The Cisco ASR 903 Router should not be installed in an enclosed rack because the chassis requires an

unobstructed flow of cooling air to maintain acceptable operating temperatures for its internal components. Installing the router in any type of enclosed rack—even with the side doors removed—could disrupt the air flow, trap heat next to the chassis, and cause an overtemperature condition inside the router. If you use an enclosed rack, ensure that there are air vents on all sides of the rack and there is proper ventilation.

Equipment Rack Guidelines

The placement of the rack can affect personnel safety, system maintenance, and the system’s ability to operate within the environmental characteristics described in the “System Specifications” section on page 1-2. Choose a proper location for the Cisco ASR 903 Router by following the following guidelines.

Locating for Safety

If the Cisco ASR 903 Router is the heaviest or the only piece of equipment in the rack, consider installing it at or near the bottom to ensure that the rack’s center of gravity is as low as possible.

For additional information about the proper placement of electronic equipment, consult the document GR-63-CORE, Network Equipment Building System (NEBS) Requirements: Physical Protection.

Locating for Easy Maintenance

Keep at least 3 feet of clear space at the front and back of the rack. This space ensures that you can remove the Cisco ASR 903 Router components and perform routine maintenance and upgrades easily.

Avoid installing the Cisco ASR 903 Router in a congested rack and consider how routing of cables from other pieces of equipment in the same rack could affect access to the router cards.

The sides of the chassis must remain unobstructed to ensure adequate airflow and prevent overheating inside the chassis.

Allow the following clearances for normal system maintenance:

At the top of the chassis—At least 3 inches (7.6 cm)

Sides of the chassis—3 to 4 ft (91.44 cm to 121.92 cm)

To avoid problems during installation and ongoing operations, follow these general precautions when you plan equipment locations and connections:

 

Cisco ASR 903 Router Hardware Installation Guide

2-16

OL-25178-05

Image 50
Contents Cisco ASR 903 Router Hardware Installation Guide Page N T E N T S Site Planning RSP Installation Troubleshooting Fan Tray LEDs Viii Document Revision History Revision Date Change SummaryDocument Conventions Document AudienceDocument Organization Title DescriptionObtaining Documentation and Submitting a Service Request Xii Cisco ASR 903 router Features A P T E RSystem Specifications Cisco ASR 903 router Chassis DesignPower Supply Features Dying Gasp DC Power SpecificationsRedundancy Status LEDsEuro-style connector AC Power Specifications Fan TrayFan Tray A903-FAN Fan Tray A903-FAN-EAir Plenum Dust Filter A903-FAN-FRSP Modules Supported RSPsNetwork Timing Interfaces Supported RSP FeaturesRSP Redundancy RSP InterfacesInterface Modules Label InterfaceGigabit Ethernet SFP Interface Module Supported SFP ModulesGigabit Ethernet RJ45 Interface Module SFP-GE-ZGigabit Ethernet XFP Interface Module Supported XFP ModulesXFP-10GER-OC192IR XFP-10GER-OC192IR-RGD T1/E1 Interface Module OC-3 Interface ModuleSerial Interface Module 11shows the interface module12 Serial Interface Module Supported Standards Standard DefinitionSerial Number Label Location Temperature SensorInterface Numbering Regulatory Compliance Cisco ASR 903 router Overview Regulatory ComplianceOL-25178-05 Preparing for Installation Safety GuidelinesStandard Warning Statements Safety Precautions for Module Installation and Removal Safety with Electricity Page OL-25178-05 Preparing for Installation Safety Guidelines Power Supply Considerations Preventing ESD DamageSite Planning General PrecautionsSite Planning Checklist Environmental Requirements Physical CharacteristicsSite Selection Guidelines Air Flow Guidelines Air exhaust Room airFloor Loading Considerations Site Power GuidelinesAir Flow Guidelines for Enclosed Rack Installation Hardware components Site Cabling GuidelinesElectrical Circuit Requirements Electromagnetic Interference Asynchronous Terminal ConnectionsInterference Considerations Radio Frequency InterferenceRack-Mounting Guidelines Precautions for Rack-MountingLightning and AC Power Fault Interference Rack Selection GuidelinesEquipment Rack Guidelines Locating for SafetyLocating for Easy Maintenance Locating for Proper Airflow Installation Checklist Verified Task DateReceiving the Cisco ASR 903 Router Creating a Site LogChassis-Lifting Guidelines Tools and EquipmentUnpacking and Verifying the Shipped Contents Component Description Installing the Router in a Rack PrerequisitesInstalling the Chassis Brackets Attaching Mounting Brackets for a 19-inch EIA RackInstalling the Router Chassis in the Rack Installing the Chassis in a 19-inch EIA RackInstalling the Chassis in the Air Plenum Installing the Chassis in a 300 mm Etsi CabinetAttaching the Cable Management Brackets Cisco ASR 903 Chassis with Air PlenumCable Management Bracket Installation Installing the Chassis Ground Connection Grounding lug 300 mm Etsi cabinet11 Stripping a Ground Wire 12 Crimping a Ground Lug onto the Ground Wire Installing the Fan Tray Installing the Dust FilterRemoving the Dust Filter Dust Filter MaintenanceRemoving and Replacing the Fan Tray 14 Detaching the Fan Tray RSP Installation 15 Fan Tray RemovalInstalling an RSP Module 16 Cisco ASR 903 Router RSP InstallationRemoving an RSP Module Hot-Swapping an RSP Module Interface Module Installation Installing an Interface ModuleRemoving an Interface Module Hot-Swapping an Interface ModuleInstalling the Power Supply Guidelines for DC-Powered Systems Preventing Power LossPower Connection Guidelines Installing the DC Power Supply Module Installing the DC Power SupplyGuidelines for AC-Powered Systems Installing Terminal Block on the DC PEM Unit A900-PWR550-D 18 Installing the DC Power Supply19 DC Power Supply with Lead Wires 20 Torquing the DC Power Supply Terminal Block Plug Screws Tools Removing and Replacing the DC Power Supply Activating the DC Power SupplyInstalling the AC power Supply Installing the AC Power Supply Module Activating the AC Power SupplyRemoving and Replacing the AC Power Supply Supply has been removed or replacedConnecting the Cisco ASR 903 Router to the Network Connecting Console CablesConnecting to the Serial Port using Microsoft Windows 2404 To disconnect the OS X USB console from the Terminal window Connecting to the Console Port using Mac OSConnecting to the Console Port using Linux Installing the Cisco Microsoft Windows 2000 USB Driver Installing the Cisco Microsoft Windows USB Device DriverInstalling the Cisco Microsoft Windows XP USB Driver Using the Add Remove Programs Utility Uninstalling the Cisco Microsoft Windows USB DriverInstalling the Cisco Microsoft Windows Vista USB Driver Using the Setup.exe ProgramConnecting to the Auxiliary Port Uninstalling the Cisco Microsoft Windows Vista USB Driver25 Connecting a Modem to the Cisco ASR 903 Router Connecting a USB Flash Device Connecting a Management Ethernet CableInstalling and Removing SFP and XFP Modules Removing a USB Flash Device Connecting Timing CablesConnecting Cables to the Bits Interface Cisco ASR 903 Router Hardware Installation Guide Connecting Cables to the Output 10Mhz or 1PPS Interface Connecting Cables to a GPS InterfaceConnecting Cables to the Input 10Mhz or 1PPS Interface Connecting Cables to the ToD InterfaceConnecting Ethernet Cables Installing the Cable Connector Connecting Cables to SFP ModulesConnecting T1/E1 cables Connecting Cables to the Patch Panel RJ45 Cable PinoutsConnecting Serial Cables Recommended Patch PanelCable Type Product Number Length Male/Female Connector EIA/TIA-530 DTE CAB-SS-530FCConnecting the Fan Tray Alarm Port Connector and Cable SpecificationsOL-25178-05 Cisco ASR 903 Router Initial Configuration Checking Conditions Prior to System StartupPowering Up the Cisco ASR 903 Router Example 4-1 Loading the Default System Boot ImageCisco ASR 903 Router Hardware Installation Guide OL-25178-05 CPP Verifying the Front Panel LEDs Configuring the Cisco ASR 903 Router at StartupVerifying the Hardware Configuration Checking Hardware and Software CompatibilityUsing the Console Interface Configuring Global ParametersChecking the Running Configuration Settings Saving the Running Configuration to NvramSafely Powering Off the Cisco ASR 903 Router Bits Port Pinout Pin Signal Name Direction DescriptionPinouts Mhz input and output 1PPS input and output GPS Port PinoutTime of Day Port Pinout Console/Aux RJ45 RS232 Serial Port Pinout Alarm Port PinoutPin Signal Name Description Board Telco Jack Line PIns Signal Name Pin Pins T1/E1 Port PinoutSerial Cable Pinouts Pin Standard DB-9 Direction Description RS-485 DB-9 Connector PinoutsRJ-45 Connector Pinouts USB Flash/MEM Port Pinout Management Ethernet Port PinoutUSB Console Port Pinout RSP LEDs Fiber-Optic SpecificationsLED Summary Interface Module LEDs Color/State Description two LEDs for eachT1/E1 portOC-3 Interface Module LEDs Color/State DescriptionLED Label Color/State Meaning T1/E1 Interface Module LEDsSerial Interface Module LEDs Power Supply LEDs Color/State MeaningFan Tray LEDs Alarm ConditionsAlarm Type Alarm Meaning OL-25178-05 Site Log and Manufactures P E N D I XDate InitialsManufactures Manufacturer Web Site or Phone Number Products/ModelOL-25178-05 D E IN-2