Chapter 1 Product Overview
Cisco 7600 Internet Router Components
Environmental Monitoring of the Power Supply
The environmental monitoring and reporting functions allow you to maintain normal system operation by resolving adverse environmental conditions prior to loss of operation.
The power supplies monitor their own internal temperature and voltages. In the event of excessive internal temperature, the power supply will shut down to prevent damage. When the power supply returns to a safe operating temperature, it will restart. In the event of an abnormal voltage on one or more outputs of the power supplies, the OUTPUT FAIL LED will light. Substantial overvoltage conditions can lead to a power supply shutdown.
The power supply front panel LEDs are described in Table
For more information about the environmental monitoring feature, refer to the Cisco 7600 Series Internet Router Software Configuration Guide.
Table
LED | Description |
|
|
INPUT OK | |
| • Green when the input voltage is OK (85 VAC or |
| greater) |
| • Off when the input voltage falls below 70 VAC or if the |
| power supply shuts down |
| |
| • Green when the input voltage is OK |
| greater) |
| • Off when the input voltage falls below |
| the power supply shuts down |
|
|
FAN OK | Green when the power supply fan is operating properly |
|
|
OUTPUT FAIL | Red when there is a problem with one or more of the |
|
|
|
|
| Cisco 7609 Internet Router Installation Guide |