Emulex Adapters manual LED Reference Information, Firmware Operation and Port Activity LEDs

Page 21

LED Reference Information

Firmware Operation and Port Activity LEDs

Emulex adapters have a POST test. Each port has a set of green and yellow LEDs (visible through openings in the adapter's mounting bracket) that indicate the conditions and results of the POST.

Green = firmware operation

Yellow = port activity

Adapter LEDs also identify possible problems. For more information on LED states, see Table 1 on page 20.

LEDs can help you locate:

Bad cables

Bad transceivers

Bad switches or hub ports

LEDs can help you determine whether:

The switch or hub is on

The driver is loaded

The driver reset the adapter

Common LED States

Although the adapter LED has many possible states, the three most common are:

Normal, that is, the link is up

Link-down or adapter waiting

Heart-beat indication

Normal Link Up

A normal link up means that the driver is loaded and talking to the switch. Everything is operational.

1 Gb/s link up:

For 1Gb/s adapters, a normal link up state is indicated with a solid green LED and a slow blinking (1 Hz) yellow LED.

For 2 Gb/s adapters, a solid green LED and a slow blinking yellow LED.

For 4 Gb/s adapters, a solid green LED and a single blinking yellow LED.

2 Gb/s link up:

For 2 Gb/s adapters, a solid green LED and a fast blinking yellow LED.

For 4 Gb/s adapters, a solid green LED and a double blinking yellow LED.

For 8 Gb/s adapters, a solid green LED and a fast double blinking yellow LED.

Troubleshooting and Maintenance Manual for LightPulse Adapters

Page 18

Image 21
Contents Troubleshooting and Maintenance Manual Page Can Not See Devices or Drives Overview Driver UpdatesBe Informed, Stay Informed, Stay Current Drivers for WindowsFirmware Updates How Emulex Device Driver Configuration Parameters Work Emulex Configuration ParametersImportance of Compatibility Emulex Utility ApplicationsObserving the Problem TroubleshootingIsolating the Problem SAN ComponentsServer Components Connectivity Checklist ChecklistsPage Upgrade Checklist Installation ChecklistConfiguration Checklist Driver Tools Tools to Collect DataHBAnyware Utility Other ways to Collect DataCommon Problems Hardware IssuesLink Down Out-of-Date Driver Version Can Not See Devices or DrivesLP21000 Checklist LP21000 ProblemsLP21000 Symptoms Out-of-Date Firmware VersionWhen to Contact Emulex Emulex Support Emulex Web Site and Emulex SupportPage Europe Contact Emulex AfterHours, Weekends or HolidaysFirmware Operation and Port Activity LEDs LED Reference InformationCommon LED States Normal Link UpLink-Down or adapter waiting Heart-beat indicationLP21000 LEDs LED Reference Table LED Table