Emulex Adapters manual When to Contact Emulex

Page 17

When to Contact Emulex

Contact Emulex if you still experience problems after you:

Review the checklists in this manual and follow any suggestions for basic troubleshooting, such as updating driver or firmware.

Verify the environment is supported.

If the adapter is a standard Emulex model, use the online knowledgebase located on the support section of www.emulex.com for resolutions to the problem. The knowledgebase is available 24/7.

If the knowledgebase does not provide an adequate solution, contact Technical Support. When contacting Technical Support, the information you need to have available will vary according to the type of problem. However, for all OSs you need the following information:

OS version and patch level.

Adapter models in use.

Firmware version installed on each adapter.

FCODE/OpenBoot/BootBIOS version installed on the adapter.

Driver version and the HBAnyware utility version installed on each affected host.

Listings or screen shots of any errors that are related to the issue.

Any changes or updates made to the SAN, OS, adapter firmware or driver lately.

A SAN map, if available.

The vendor make and model of storage in use.

In addition, the following information is needed for these specific OSs:

For Linux (at a minimum)

A copy of /var/log/messages and any logs the Emulex installer scripts provide.

If possible: the tarball output of the Emulex System Grab Diagnostic Tool found on the Linux support section of the Emulex Web site.

For Solaris with the lpfc driver

A copy of /var/adm/messages.

A copy of /kernel/drv/lpfc.conf.

A copy of /kernel/drv/st.conf (for tape).

A copy of /kernel/drv/sd.conf (for disk).

For Solaris with the SFS FCA driver:

The versions of the SFS packages or patches installed.

A copy of /kernel/drv/emlxs.conf.

For Windows:

A copy of the System Event log.

For the HBAnyware utility, a copy of the Applications Event log.

For HP-UX:

A copy of the output of command 'ioscan -fkn'.

For Netware:

A capture of all messages when the server is started (if possible).

Troubleshooting and Maintenance Manual for LightPulse Adapters

Page 14

Image 17
Contents Troubleshooting and Maintenance Manual Page Can Not See Devices or Drives Overview Driver UpdatesBe Informed, Stay Informed, Stay Current Drivers for WindowsFirmware Updates How Emulex Device Driver Configuration Parameters Work Emulex Configuration ParametersImportance of Compatibility Emulex Utility ApplicationsObserving the Problem TroubleshootingServer Components Isolating the ProblemSAN Components Connectivity Checklist ChecklistsPage Upgrade Checklist Installation ChecklistConfiguration Checklist Driver Tools Tools to Collect DataHBAnyware Utility Other ways to Collect DataLink Down Common ProblemsHardware Issues Out-of-Date Driver Version Can Not See Devices or DrivesLP21000 Checklist LP21000 ProblemsLP21000 Symptoms Out-of-Date Firmware VersionWhen to Contact Emulex Emulex Support Emulex Web Site and Emulex SupportPage Europe Contact Emulex AfterHours, Weekends or HolidaysFirmware Operation and Port Activity LEDs LED Reference InformationCommon LED States Normal Link UpLP21000 LEDs Link-Down or adapter waitingHeart-beat indication LED Reference Table LED Table