Emulex Adapters manual LED Table, LED Reference Table

Page 23

LED Table

Note: All states except link rate apply to both HBAs and CNAs. The 4 Gb/s link rate is applicable to both HBAs and CNAs. The 2 Gb/s and 8 Gb/s link speed apply to HBAs only.

Table 1: LED Reference Table

Yellow LED

Green LED

State

 

 

 

Off

Off

Wake-up failure (dead board)

 

 

 

On

Off

POST failure (dead board)

 

 

 

Slow blink

Off

Wake-up failure monitor

 

 

 

Fast blink

Off

POST failure

 

 

 

Flashing

Off

POST process in progress

 

 

 

Off

On

Failure while functioning

 

 

 

On

On

Failure while functioning

 

 

 

8-Gb/s adapters:

 

 

2 blinks

On

2-Gb/s link rate - normal, link is up

3 blinks

On

4-Gb/s link rate - normal, link is up

4 blinks

On

8-Gb/s link rate - normal, link is up

 

 

 

4-Gb/s adapters:

 

 

1 blink

On

1-Gb/s link rate - normal, link is up

2 blinks

On

2-Gb/s link rate - normal, link is up

3 blinks

On

4-Gb/s link rate - normal, link is up

 

 

 

2-Gb/s adapters:

 

 

Slow blink

On

1-Gb/s link rate - normal, link is up

Fast blink

On

2-Gb/s link rate - normal, link is up

 

 

 

Off

Slow blink

Normal - link down or not started

 

 

 

Slow blink

Slow blink

Offline for download

 

 

 

Fast blink

Slow blink

Restricted offline mode (waiting for restart)

 

 

 

Flashing

Slow blink

Restricted offline mode (test active)

 

 

 

Troubleshooting and Maintenance Manual for LightPulse Adapters

Page 20

Image 23
Contents Troubleshooting and Maintenance Manual Page Can Not See Devices or Drives Drivers for Windows Driver UpdatesOverview Be Informed, Stay Informed, Stay CurrentFirmware Updates Emulex Utility Applications Emulex Configuration ParametersHow Emulex Device Driver Configuration Parameters Work Importance of CompatibilityObserving the Problem TroubleshootingServer Components Isolating the ProblemSAN Components Connectivity Checklist ChecklistsPage Upgrade Checklist Installation ChecklistConfiguration Checklist Other ways to Collect Data Tools to Collect DataDriver Tools HBAnyware UtilityLink Down Common ProblemsHardware Issues Out-of-Date Driver Version Can Not See Devices or DrivesOut-of-Date Firmware Version LP21000 ProblemsLP21000 Checklist LP21000 SymptomsWhen to Contact Emulex Emulex Support Emulex Web Site and Emulex SupportPage Europe Contact Emulex AfterHours, Weekends or HolidaysNormal Link Up LED Reference InformationFirmware Operation and Port Activity LEDs Common LED StatesLP21000 LEDs Link-Down or adapter waitingHeart-beat indication LED Reference Table LED Table