Cabletron Systems TRFMIM-28 The function of the INB Receive LEDs is listed in Table, LANVIEW LEDs

Page 36
LANVIEW LEDs

LANVIEW LEDs

The function of the two System Status LEDs, System Management Bus (SMB) and CPU (Central Processing Unit), are listed in Table 4-1.

Table 4-1. System Status (SMB and CPU) LEDs

LED Color

State

Description

 

 

 

 

 

 

Green

Functional

Fully operational

 

 

 

Yellow

Testing

Power up testing

 

 

 

Yellow (Blinking)

Crippled

Not fully operational (i.e. one port may be bad)

 

 

 

Yellow/Green

Booting

Module is performing its boot process

 

 

 

Red

Reset

Module is resetting

 

 

 

Red (Blinking)

Failed

Fatal error

 

 

 

Off

Power off

Module powered off

 

 

 

The function of the INB Receive LEDs is listed in Table 4-2.

 

Table 4-2. INB Receive LEDs

 

 

LED Color

State

 

 

 

 

Green

Link, no activity, port enabled

 

 

Green (Blinking)

Link, port disabled

 

 

Yellow (Flashing)

Link, activity, port enabled (Flashing to steady on indicates rate.)

 

 

Red

INB fault, (not synchronized with the Monarch)

 

 

Off

No link, no activity (port enabled)

 

 

The function of the INB Transmit LEDs is listed in Table 4-3.

 

Table 4-3. INB Transmit LEDs

 

 

LED Color

State

 

 

 

 

Green (Flashing)

Activity, port enabled (Flashing to steady on indicates rate.)

 

 

Yellow (Blinking)

Port in standby state

 

 

Red

INB fault

 

 

Off

Link (port disabled)

 

 

4-2

Image 36
Contents SmartSwitch 9H423-28 User’s Guide 9032061-01Page Copyright March 1998 by Cabletron Systems, Inc 35 Industrial Way FCC Notice VCCI NoticeDOC Notice DECLARATION OF CONFORMITY ADDENDUM Nexus House, Newbury Business ParkConformance to Directives/Product Standards Safety Information CLASS 1 LASER TRANSCEIVERSThe FPIM-05 and FPIM-07 are Class 1 Laser Products CLASS 1 LASER TRANSCEIVERS Laser Radiation and Connectors Page Contents Installing the 9H423-28 ModuleChapter IntroductionSpecifications Contentsviii Introduction ChapterFeatures Fast Packet SwitchingProcessor ManagementThe 9H423-28 module provides MIB support including RMON RFC-1271 LANVIEW LEDs Figure 1-1. The 9H423-28 Module 26X 25XFAST ENET 9H423-28 SMB CPU INB FAST ENETRelated Manuals Getting HelpInstalling the 9H423-28 Module Installing an FEPIMUnpacking the Module User Accessible Components Setting the Module DIP Switch Table 2-1. Function of DIP Switch See the Cautions at the end of this tableInstalling the Module in the SmartSwitch 9000 Chassis Figure 2-3. Installing the Module Plastic Tab Jack for ESD Wrist StrapMetal Back-Panel ModuleThe Reset Switch Reset SwitchInstalling the 9H423-28 Module Operation ENIB/FENIB OperationSmartSwitch ASIC Traditional SwitchVLAN VLAN Domains SecureFast VLAN Switches Fully-Meshed VLAN Domainsi960 Core INB NIBSystem Management Buses SMB-1 BusSystem Diagnostic Controller DC/DC ConverterINB Interface SMB-10 BusITDM Arbitration Levels ITDM RAM Allocation LevelRound Robin Arbitration Level Lowest Slot Number LevelMonarch/Slave SmartSwitch 9000 Modules 3-10 LANVIEW LEDs INB ReceivePort Transmit System Status INB Transmit Port ReceiveThe function of the INB Receive LEDs is listed in Table The function of the INB Transmit LEDs is listed in TableLANVIEW LEDs The function of the Port Receive LEDs is listed in Table The function of the Port Transmit LEDs is listed in TableTable 4-4. Port Receive LEDs Table 4-5. Port Transmit LEDsLANVIEW LEDs Specifications Technical SpecificationsMemory StandardsSafety ServiceDimensions WeightEnvironment Operating Temperature5 to 40 C Storage TemperatureSpecifications FEPIM Specifications FE-100TXFE-100FX Appendix AFE-100FX FEPIM Specifications