Cabletron Systems FDDI manual FPIM-02 and FPIM-04

Page 16

Chapter 2: Network Requirements

Table 2-2 Transmitter Power Parameters

 

 

Worst

Worst

Typical

Parameter

Typical Value

Case

Case

Budget

 

 

Budget

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50/125 m

-13.0 dBm

-15.0 dBm

13.0 dB

17.5 dB

fiber

 

 

 

 

 

 

 

 

 

62.5/125

-10.0 dBm

-12.0 dBm

16.0 dB

20.5 dB

m fiber

 

 

 

 

 

 

 

 

 

100/140 m

-7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

fiber

 

 

 

 

 

 

 

 

 

Error Rate

Better than 10-10

 

 

 

 

 

 

 

 

The link distance is up to 2 kilometers on the multimode fiber optic cable as specified by ANSI MMF-PMD.

2.1.2FPIM-02 and FPIM-04

The FPIM-02 has an RJ-45 connector supporting an Unshielded Twisted Pair (UTP) connection. The FPIM-04 has an RJ-45 connector supporting a Shielded Twisted Pair (STP) connection. The pinouts for both are listed in Table 2-3.

Table 2-3 FPIM-02 and FPIM-04 Pinouts

Pin Number

Represents

Pin Number

Represents

 

 

 

 

 

 

 

 

1

Transmit+

5

NA

 

 

 

 

2

Transmit-

6

NA

 

 

 

 

3

NA

7

Receive+

 

 

 

 

4

NA

8

Receive-

 

 

 

 

The link distance is up to 100 meters on unshielded twisted pair cable as specified by ANSI TP-PMD.

2-2 7F06-02 FDDI SmartSwitch Interface Module User’s Guide

Image 16
Contents 7F06-02 Fddi SmartSwitch Interface Module User’s Guide Page 7F06-02 Fddi SmartSwitch Interface Module User’s Guide FCC NoticeVcci Notice DOC NoticeCabletron SYSTEMS, INC. Program License Agreement Cabletron Software Program License Exclusion of Warranty and Disclaimer of LiabilityUnited States Government Restricted Rights Declaration of Conformity PO Box Rochester, NHContents Contents Chapter Introduction Using this Manual7F06-02 Module Cable Type and FPIMs 7F06-02 ModuleFPIMs FeaturesLanview LEDs Connectivity Related ManualsService and Support Getting Help7F06-02 Fddi SmartSwitch Interface Module User’s Guide Chapter Network Requirements Fpim Module SpecificationsFPIM-00 and FPIM-01 FPIM-02 and FPIM-04 FPIM-05 and FPIM-07 Parameter Typical Minimum Maximum7F06-02 Fddi SmartSwitch Interface Module User’s Guide Chapter INSTALLATION/REMOVAL Unpacking the 7F06-02 ModuleInstalling Fpims Installing an FpimINSTALLING/REMOVING the 7F06-02 Module Installing in the 7C03 SmartSwitchRemoving from the 7C03 SmartSwitch Removing the 7F06-02 Module from the 7C03 Mmac SmartSwitchInstalling in the 7C04 or 7C04-R Workgroup SmartSwitch Screw Screws Ejector Tabs Installation/Removal Chapter Troubleshooting Diagnostic and Monitoring SystemPort Transmit Leds Port Receive LedsA/B Link Leds Twisted A-A, B-B 7F06-02 Fddi SmartSwitch Interface Module User’s Guide Chapter Technical Specifications StandardsEMI EMCSafety ServiceDimensions Weight